A review on electrical impedance tomography for pulmonary perfusion imaging

Although electrical impedance tomography (EIT) for ventilation monitoring is on the verge of clinical trials, pulmonary perfusion imaging with EIT remains a challenge, especially in spontaneously breathing subjects. In anticipation of more research on this subject, we believe a thorough review is called for. In this paper, findings related to the physiological origins and electrical characteristics of this signal are summarized, highlighting properties that are particularly relevant to EIT. The perfusion impedance change signal is significantly smaller in amplitude compared with the changes due to ventilation. Therefore, the hardware used for this purpose must be more sensitive and more resilient to noise. In previous works, some signal- or image-processing methods have been required to separate these two signals. Three different techniques are reviewed in this paper, including the ECG-gating method, frequency-domain-filtering-based methods and a principal-component-analysis-based method. In addition, we review a number of experimental studies on both human and animal subjects that employed EIT for perfusion imaging, with promising results in the diagnosis of pulmonary embolism (PE) and pulmonary arterial hypertension as well as other potential applications. In our opinion, PE is most likely to become the main focus for perfusion EIT in the future, especially for heavily instrumented patients in the intensive care unit (ICU).

[1]  B. M. Eyuboglu,et al.  In vivo imaging of cardiac related impedance changes , 1989, IEEE Engineering in Medicine and Biology Magazine.

[2]  T K Hames,et al.  Pulmonary perfusion and ventricular ejection imaging by frequency domain filtering of EIT images , 1992 .

[3]  Inéz Frerichs,et al.  Assessment of Changes in Distribution of Lung Perfusion by Electrical Impedance Tomography , 2009, Respiration.

[4]  J. Marcus,et al.  Pulmonary perfusion measured by means of electrical impedance tomography , 1998, Physiological measurement.

[5]  Inéz Frerichs,et al.  Regional distribution of blood volume within the preterm infant thorax during synchronised mechanical ventilation , 2010, Intensive Care Medicine.

[6]  P Nopp,et al.  Cardiac-related changes in lung resistivity as a function of frequency and location obtained from EITS images. , 1996, Physiological measurement.

[7]  Liliana Borcea,et al.  Electrical impedance tomography , 2002 .

[8]  Günter Hahn,et al.  Lung impedance measurements to monitor alveolar ventilation , 2011, Current opinion in critical care.

[9]  B H Brown,et al.  Electrical impedance tomography (EIT): a review , 2003, Journal of medical engineering & technology.

[10]  Marc Bodenstein,et al.  Principles of electrical impedance tomography and its clinical application , 2009, Critical care medicine.

[11]  R Pikkemaat,et al.  Separation of ventilation and perfusion related signals within EIT-data streams , 2010 .

[12]  Anton Vonk-Noordegraaf,et al.  Assessment of the Pulmonary Volume Pulse in Idiopathic Pulmonary Arterial Hypertension by Means of Electrical Impedance Tomography , 2006, Respiration.

[13]  Caroline A Grant,et al.  Measurement of ventilation and cardiac related impedance changes with electrical impedance tomography , 2011, Critical care.

[14]  Gerardo Tusman,et al.  Regional lung perfusion estimated by electrical impedance tomography in a piglet model of lung collapse. , 2012, Journal of applied physiology.

[15]  A. Morice,et al.  Cardiac and respiratory related electrical impedance changes in the human thorax , 1994, IEEE Transactions on Biomedical Engineering.

[16]  S Leonhardt,et al.  Dynamic separation of pulmonary and cardiac changes in electrical impedance tomography , 2008, Physiological measurement.

[17]  T. Faes,et al.  Electrical impedance tomography to measure pulmonary perfusion: is the reproducibility high enough for clinical practice? , 2003, Physiological measurement.

[18]  D C Barber,et al.  An assessment of dynamic images by applied potential tomography for monitoring pulmonary perfusion. , 1988, Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics.

[19]  B H Brown,et al.  A comparison of ventilatory and cardiac related changes in EIT images of normal human lungs and of lungs with pulmonary emboli. , 1994, Physiological measurement.

[20]  J. Marcus,et al.  Determinants of pulmonary perfusion measured by electrical impedance tomography , 2004, European Journal of Applied Physiology.

[21]  B. Brown,et al.  Recent Developments in Applied Potential Tomography-APT , 1986 .

[22]  Peter Herrmann,et al.  Regional Lung Perfusion as Determined by Electrical Impedance Tomography in Comparison With Electron Beam CT Imaging , 2002, IEEE Transactions on Medical Imaging.

[23]  Anton Vonk-Noordegraaf,et al.  Pulmonary vascular responses to hypoxia and hyperoxia in healthy volunteers and COPD patients measured by electrical impedance tomography. , 2003, Chest.

[24]  D S Holder,et al.  A review of errors in multi-frequency EIT instrumentation , 2007, Physiological measurement.

[25]  S. Söndergaard,et al.  Electrical impedence tomography and heterogeneity of pulmonary perfusion and ventilation in porcine acute lung injury , 2009, Acta anaesthesiologica Scandinavica.

[26]  O. Stenqvist,et al.  Monitoring pulmonary perfusion by electrical impedance tomography: an evaluation in a pig model , 2009, Acta anaesthesiologica Scandinavica.

[27]  O. Hoekstra,et al.  Ventilation and perfusion imaging by electrical impedance tomography: a comparison with radionuclide scanning. , 1998, Physiological measurement.