Quantitative modeling of the accuracy in registering preoperative patient-specific anatomic models into left atrial cardiac ablation procedures.

PURPOSE In cardiac ablation therapy, accurate anatomic guidance is necessary to create effective tissue lesions for elimination of left atrial fibrillation. While fluoroscopy, ultrasound, and electroanatomic maps are important guidance tools, they lack information regarding detailed patient anatomy which can be obtained from high resolution imaging techniques. For this reason, there has been significant effort in incorporating detailed, patient-specific models generated from preoperative imaging datasets into the procedure. Both clinical and animal studies have investigated registration and targeting accuracy when using preoperative models; however, the effect of various error sources on registration accuracy has not been quantitatively evaluated. METHODS Data from phantom, canine, and patient studies are used to model and evaluate registration accuracy. In the phantom studies, data are collected using a magnetically tracked catheter on a static phantom model. Monte Carlo simulation studies were run to evaluate both baseline errors as well as the effect of different sources of error that would be present in a dynamic in vivo setting. Error is simulated by varying the variance parameters on the landmark fiducial, physical target, and surface point locations in the phantom simulation studies. In vivo validation studies were undertaken in six canines in which metal clips were placed in the left atrium to serve as ground truth points. A small clinical evaluation was completed in three patients. Landmark-based and combined landmark and surface-based registration algorithms were evaluated in all studies. In the phantom and canine studies, both target registration error and point-to-surface error are used to assess accuracy. In the patient studies, no ground truth is available and registration accuracy is quantified using point-to-surface error only. RESULTS The phantom simulation studies demonstrated that combined landmark and surface-based registration improved landmark-only registration provided the noise in the surface points is not excessively high. Increased variability on the landmark fiducials resulted in increased registration errors; however, refinement of the initial landmark registration by the surface-based algorithm can compensate for small initial misalignments. The surface-based registration algorithm is quite robust to noise on the surface points and continues to improve landmark registration even at high levels of noise on the surface points. Both the canine and patient studies also demonstrate that combined landmark and surface registration has lower errors than landmark registration alone. CONCLUSIONS In this work, we describe a model for evaluating the impact of noise variability on the input parameters of a registration algorithm in the context of cardiac ablation therapy. The model can be used to predict both registration error as well as assess which inputs have the largest effect on registration accuracy.

[1]  J. Michael Fitzpatrick,et al.  General Approach to First-Order Error Prediction in Rigid Point Registration , 2011, IEEE Transactions on Medical Imaging.

[2]  Frank Sauer,et al.  Registration of high-resolution 3D atrial images with electroanatomical cardiac mapping: evaluation of registration methodology , 2005, SPIE Medical Imaging.

[3]  Hugh Calkins,et al.  Anatomic Stereotactic Catheter Ablation on Three-Dimensional Magnetic Resonance Images in Real Time , 2003, Circulation.

[4]  H. Nesser,et al.  Accuracy of integration of multislice computed tomography imaging into three-dimensional electroanatomic mapping for real-time guided radiofrequency ablation of left atrial fibrillation—Influence of heart rhythm and radiofrequency lesions , 2007, Journal of Interventional Cardiac Electrophysiology.

[5]  J. Ruskin,et al.  Integration of cardiac magnetic resonance imaging with three-dimensional electroanatomic mapping to guide left ventricular catheter manipulation: feasibility in a porcine model of healed myocardial infarction. , 2004, Journal of the American College of Cardiology.

[6]  J Clémenty,et al.  Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins. , 1998, The New England journal of medicine.

[7]  Jeremy N Ruskin,et al.  Integration of Cardiac CT/MR Imaging with Three‐Dimensional Electroanatomical Mapping to Guide Catheter Manipulation in the Left Atrium: Implications for Catheter Ablation of Atrial Fibrillation , 2006, Journal of cardiovascular electrophysiology.

[8]  Richard A. Robb,et al.  Validation of semi-automatic segmentation of the left atrium , 2008, SPIE Medical Imaging.

[9]  Optimizing Catheter Navigation for AF Ablation: Do Not Just Follow the Map! , 2007, Journal of cardiovascular electrophysiology.

[10]  S. Knecht,et al.  How to perform linear lesions. , 2007, Heart rhythm.

[11]  Hugh Calkins,et al.  Initial Experience in the Use of Integrated Electroanatomic Mapping with Three‐Dimensional MR/CT Images to Guide Catheter Ablation of Atrial Fibrillation , 2006, Journal of cardiovascular electrophysiology.

[12]  J. Ruskin,et al.  HRS/EHRA/ECAS expert Consensus Statement on catheter and surgical ablation of atrial fibrillation: recommendations for personnel, policy, procedures and follow-up. A report of the Heart Rhythm Society (HRS) Task Force on catheter and surgical ablation of atrial fibrillation. , 2007, Heart rhythm.

[13]  Eric Voth,et al.  Validation of Computed Tomography Image Integration into the EnSite NavX Mapping System to Perform Catheter Ablation of Atrial Fibrillation , 2008, Journal of cardiovascular electrophysiology.

[14]  Richard A. Robb,et al.  An event-driven distributed processing architecture for image-guided cardiac ablation therapy , 2009, Comput. Methods Programs Biomed..

[15]  Katja Zeppenfeld,et al.  Fusion of multislice computed tomography imaging with three-dimensional electroanatomic mapping to guide radiofrequency catheter ablation procedures. , 2005, Heart rhythm.

[16]  R A Robb,et al.  Patient-specific anatomic models. Geometric surface generation from three-dimensional medical images using a specified polygonal budget. , 1996, Studies in health technology and informatics.

[17]  Jasbir Sra Cardiac image integration implications for atrial fibrillation ablation , 2007, Journal of Interventional Cardiac Electrophysiology.

[18]  H. Halperin,et al.  Integrated Electroanatomic Mapping With Three-Dimensional Computed Tomographic Images for Real-Time Guided Ablations , 2006, Circulation.

[19]  Malcolm C. Finlay,et al.  A randomised comparison of Cartomerge vs. NavX fusion in the catheter ablation of atrial fibrillation: The CAVERN Trial , 2011, Journal of Interventional Cardiac Electrophysiology.

[20]  Kim Rajappan,et al.  The Impact of CT Image Integration into an Electroanatomic Mapping System on Clinical Outcomes of Catheter Ablation of Atrial Fibrillation , 2006, Journal of cardiovascular electrophysiology.

[21]  VAMSEE RANGAVAJHALA,et al.  Dynamic Registration of Preablation Imaging With a Catheter Geometry to Guide Ablation in a Swine Model: Validation of Image Integration and Assessment of Catheter Navigation Accuracy , 2010, Journal of cardiovascular electrophysiology.

[22]  Luca Faes,et al.  A stochastic approach for automatic registration and fusion of left atrial electroanatomic maps with 3D CT anatomical images , 2007, Physics in medicine and biology.

[23]  Andrea Natale,et al.  Intracardiac Echo‐Guided Image Integration: Optimizing Strategies for Registration , 2007, Journal of cardiovascular electrophysiology.

[24]  D. Schwartzman,et al.  An improved algorithm for intraoperative registration of computed tomographic left atrial images. , 2011, Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology.

[25]  Darin Okerlund,et al.  Feasibility and validation of registration of three-dimensional left atrial models derived from computed tomography with a noncontact cardiac mapping system. , 2005, Heart rhythm.

[26]  S. Ernst,et al.  Recovered Pulmonary Vein Conduction as a Dominant Factor for Recurrent Atrial Tachyarrhythmias After Complete Circular Isolation of the Pulmonary Veins: Lessons From Double Lasso Technique , 2005, Circulation.

[27]  L. Hsu Image integration for catheter ablation: searching for the perfect match. , 2008, Heart rhythm.

[28]  R. Cappato,et al.  Prospective Assessment of Late Conduction Recurrence Across Radiofrequency Lesions Producing Electrical Disconnection at the Pulmonary Vein Ostium in Patients With Atrial Fibrillation , 2003, Circulation.