Motion planning in stereotaxic radiosurgery

Stereotaxic radiosurgery is a procedure that uses a beam of radiation as an ablative surgical instrument to destroy brain tumors (or more generally, brain lesions). The beam is produced by a linear accelerator that is moved by a mechanical gantry. Radiation is concentrated by crossfiring at the tumor from multiple directions, to reduce the amount of energy deposited in healthy tissues. Because access to and exit from the tumor is obstructed along some directions by critical structures (e.g., brain stem, optic nerves), planning the path of the beam is often difficult and time-consuming. This paper describes a computer-based planner developed to interactively assist the surgeon generate a satisfactory treatment, given the spatial distribution of the brain tissues obtained with medical imaging. This planner has been experimented on using 11 cases previously processed at the Stanford Medical Center. A dosimetric comparison with the manually generated plans for these cases was carried but. Although still limited, results indicate that automatic planning can significantly improve energy deposition. It can also shorten the overall treatment, hence reducing the patient's pain and allowing the radiosurgery equipment to be used for more patients. Stereotaxic radiosurgery is an example of so-called "bloodless surgery." Computer-based planning techniques are expected to facilitate further development of this safer, less painful, and more cost effective type of surgery. >

[1]  R. Cormack,et al.  A problem in rotation therapy with X-rays: dose distributions with an axis of symmetry. , 1987, International journal of radiation oncology, biology, physics.

[2]  W Schlegel,et al.  Cerebral radiation surgery using moving field irradiation at a linear accelerator facility. , 1985, International journal of radiation oncology, biology, physics.

[3]  K. Winston,et al.  Linear accelerator as a neurosurgical tool for stereotactic radiosurgery. , 1988, Neurosurgery.

[4]  K. Winston,et al.  A system for stereotactic radiosurgery with a linear accelerator. , 1986, International journal of radiation oncology, biology, physics.

[5]  C Munari,et al.  Stereotactic radiosurgery with the linear accelerator: treatment of arteriovenous malformations. , 1989, Neurosurgery.

[6]  Leonidas J. Guibas,et al.  Topologically sweeping an arrangement , 1986, STOC '86.

[7]  Peter Kazanzides,et al.  A surgical robot for total hip replacement surgery , 1992, Proceedings 1992 IEEE International Conference on Robotics and Automation.

[8]  Leonidas J. Guibas,et al.  Computing convolutions by reciprocal search , 1986, SCG '86.

[9]  Philippe Cinquin,et al.  Image guided operating robot: a clinical application in stereotactic neurosurgery , 1992, Proceedings 1992 IEEE International Conference on Robotics and Automation.

[10]  E B Podgorsak,et al.  Dose distributions in dynamic stereotactic radiosurgery. , 1987, Medical physics.

[11]  A. Cormack,et al.  A problem in rotation therapy with X rays. , 1987, International journal of radiation oncology, biology, physics.

[12]  L. Leksell,et al.  Cerebral radiosurgery. I. Gammathalanotomy in two cases of intractable pain. , 1968, Acta chirurgica Scandinavica.

[13]  M Pla,et al.  Dynamic stereotactic radiosurgery. , 1988, International journal of radiation oncology, biology, physics.

[14]  P. Cinquin,et al.  Dynamic Segmentation : Detecting Complex Topology 3D-object , 1991, Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society Volume 13: 1991.

[15]  A Brahme,et al.  Solution of an integral equation encountered in rotation therapy. , 1982, Physics in medicine and biology.

[16]  P. Gutin,et al.  Interstitial irradiation of brain tumors: a review. , 1981, Neurosurgery.

[17]  A. Brahme,et al.  Optimization of stationary and moving beam radiation therapy techniques. , 1988, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[18]  H M Kooy,et al.  The verification of an inverse problem in radiation therapy. , 1990, International journal of radiation oncology, biology, physics.

[19]  Herbert Edelsbrunner,et al.  Algorithms in Combinatorial Geometry , 1987, EATCS Monographs in Theoretical Computer Science.

[20]  Tomás Lozano-Pérez,et al.  Spatial Planning: A Configuration Space Approach , 1983, IEEE Transactions on Computers.

[21]  N. Barth,et al.  An inverse problem in radiation therapy. , 1990, International journal of radiation oncology, biology, physics.

[22]  Laurent D. Cohen,et al.  Using Deformable Surfaces to Segment 3-D Images and Infer Differential Structures , 1992, ECCV.

[23]  L. Leksell,et al.  The High-Energy Proton Beam as a Neurosurgical Tool , 1958, Nature.