This paper presents an islanding detection technique using superimposed positive sequence voltage and current for microgrid system. The conventional passive methods have the drawback of non-detection zone (NDZ), and active islanding detection methods introduce disturbance which might cause problems with reliability, stability, and power quality on a power system. Two systems are simulated using RSCAD/RTDS software and several test cases are generated to test the performance of the proposed technique.

[1]  F.Z. Peng,et al.  Survey of photovoltaic power systems islanding detection methods , 2008, 2008 34th Annual Conference of IEEE Industrial Electronics.

[2]  S. Conti,et al.  Intentional islanding of MV microgrids: Discussion of a case study and analysis of simulation results , 2008, 2008 International Symposium on Power Electronics, Electrical Drives, Automation and Motion.

[3]  Kwang-Ho Kim,et al.  Development of a logical rule-based islanding detection method for distributed resources , 2002, 2002 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.02CH37309).

[4]  Yu Zhang,et al.  Evaluation of anti-islanding schemes based on nondetection zone concept , 2004, IEEE Transactions on Power Electronics.

[5]  Fang Zheng Peng,et al.  Control for Grid-Connected and Intentional Islanding Operations of Distributed Power Generation , 2011, IEEE Transactions on Industrial Electronics.

[6]  Miles A Redfern,et al.  A new microprocessor based islanding protection algorithm for dispersed storage and generation units , 1995 .

[7]  E.F. El-Saadany,et al.  Intentional islanding of distributed generation , 2005, IEEE Power Engineering Society General Meeting, 2005.

[8]  Miles A Redfern,et al.  Protection against loss of utility grid supply for a dispersed storage and generation unit , 1993 .

[9]  S. I. Jang,et al.  A new islanding detection algorithm for distributed generations interconnected with utility networks , 2004 .

[10]  W. Bower,et al.  Evaluation of Islanding Detection Methods for Utility-Interactive Inverters in Photovoltaic Systems , 2002 .

[11]  Fei Wang,et al.  Power Equations and Non-Detection Zone of Passive Islanding Detection and Protection Method for Grid Connected Photovoltaic Generation System , 2009, 2009 Pacific-Asia Conference on Circuits, Communications and Systems.

[12]  Jeyraj Selvaraj,et al.  Implementation of TMS320F2812 in islanding detection for Photovoltaic Grid Connected Inverter , 2009, 2009 International Conference for Technical Postgraduates (TECHPOS).

[13]  S.P. Chowdhury,et al.  UK scenario of islanded operation of active distribution networks — A survey , 2008, 2008 IEEE Power and Energy Society General Meeting - Conversion and Delivery of Electrical Energy in the 21st Century.

[14]  J.L. Kirtley,et al.  A Simple Technique for Islanding Detection With Negligible Nondetection Zone , 2009, IEEE Transactions on Power Delivery.