Occupational Skin Hazards from Synthetic Plastics

Epoxy and acrylic resins have numerous industrial applications but are also widely used in the household environment. These compounds are presently one of the most important sources of occupational contact dermatitis. Contact sensitization to epoxy resins is usually caused by the resin itself but hardeners or other additives, such as reactive diluents, plasticizers, fillers and pigments, can occasionally be responsible. Since completely cured epoxy resins are not sensitizers, epoxy resin sensitization is always due to the presence, in the final polymer, of uncured allergenic low molecular weight oligomers. Acrylates are now considered the fourth most common cause of contact sensitization due to resins. Unpolymerized monomers of acrylic compounds are known to be responsible for the contact allergy. Accelerators, inhibitors and catalysts, which are usually added to the acrylates to promote the polymerization process, can also sensitize. Both allergic and irritant contact dermatitis may be caused by exposure to epoxy or acrylic resins and their additives. Contact urticaria, allergic or irritant airborne contact dermatitis caused by volatile compounds, onychia and paronychia can also occur. From January of 1984 to May of 1992 we detected 39 cases of occupational allergic contact dermatitis to epoxy resin system substances and 11 cases of occupational contact sensitization to acrylic compounds. In our experience, the electronics industry as well as paint and glue related activities were the most important sources of epoxy sensitization. Dental materials and anaerobic sealants were found to be the most frequent acrylate sensitizers.

[1]  M. Bergman,et al.  Hypersensitivity reactions to dental materials in a referred group of patients. , 1989, Scandinavian journal of dental research.

[2]  D. Belsito Contact dermatitis to ethyl‐cyanoacrylate‐containing glue , 1987, Contact dermatitis.

[3]  G. T. Kuwada,et al.  Contact dermatitis. A review. , 1986, Clinics in podiatric medicine and surgery.

[4]  T. Estlander,et al.  Sensitization to patch test acrylates , 1988, Contact dermatitis.

[5]  T. Estlander Occupational skin disease in Finland. Observations made during 1974-1988 at the Institute of Occupational Health, Helsinki. , 1990, Acta dermato-venereologica. Supplementum.

[6]  J. Lachapelle Industrial airborne irritant or allergic contact dermatitis. , 1986, Contact dermatitis.

[7]  K. Andersen,et al.  Allergic hand dermatitis from 2‐hydroxyethyl‐acrylate in contact lenses , 1986, Contact dermatitis.

[8]  T. Aw,et al.  Dermatological hazards in the electronics industry , 1990, Contact dermatitis.

[9]  A. Tosti,et al.  Allergic contact dermatitis due to benzoyl peroxide in an arm prosthesis , 1991, Contact dermatitis.

[10]  S. Fregert,et al.  Simple methods for demonstration of epoxy resins of bisphenol A type , 1978, Contact dermatitis.

[11]  A. Giacchetti,et al.  Unusual sensitization to cyanoacrylate ester , 1986, Contact dermatitis.

[12]  P. Coenraads,et al.  Hand dermatoses and contact allergic reactions in construction workers exposed to epoxy resins , 1984, Contact dermatitis.

[13]  V. Patussi,et al.  Contact dermatitis to Loctite 221 and 270 , 1987, Contact dermatitis.

[14]  B. Piraccini,et al.  Occupational airborne contact dermatitis due to ethylene glycol dimethacrylate , 1991, Contact dermatitis.

[15]  P. Frosch,et al.  Contact dermatitis , 1987, Contact dermatitis.

[16]  A. Tosti,et al.  Occupational airborne contact dermatitis due to epoxy resin , 1988, Contact dermatitis.

[17]  T. Estlander,et al.  Allergic contact dermatitis from non‐diglycidyl‐ether‐of‐bisphenol‐A epoxy resins , 1991, Contact dermatitis.

[18]  T. Estlander,et al.  Occupational Allergic Contact Dermatitis from Acrylates: Observations Concerning Anaerobic Acrylic Sealants and Dental Composite Resins , 1989 .

[19]  J. Nater,et al.  Protection against epoxy resins with glove materials , 1987, Contact dermatitis.

[20]  T. Estlander,et al.  Occupational dermatoses from epoxy resin compounds , 1990, Contact dermatitis.

[21]  A. Geursen‐Reitsma,et al.  Contact dermatitis caused by urethane acrylates in a hearing aid , 1991, Contact dermatitis.

[22]  L. Condé‐Salazar,et al.  Occupational dermatitis from glass fiber , 1985, Contact dermatitis.

[23]  A. Ancona,et al.  Contact dermatitis in hospital patients. , 1990, Dermatologic clinics.

[24]  J. S. Taylor Acrylic Reactions — Ten-Years’ Experience , 1989 .

[25]  S. Freeman Occupational skin disease. , 1995, Current problems in dermatology.

[26]  D. Guimaraens,et al.  Occupational allergic contact dermatitis from anaerobic acrylic sealants , 1988, Contact dermatitis.

[27]  A. Freiburghaus,et al.  Contact dermatitis from acrylate and methacrylate compounds in Lowicryl® embedding media for electron microscopy , 1990, Contact dermatitis.

[28]  K. Malten Recently reported causes of contact dermatitis due to synthetic resins and hardeners , 1979, Contact dermatitis.

[29]  J. Rønnevig,et al.  The immunology of Contact dermatitis , 1989, Contact dermatitis.

[30]  M. Gasperini,et al.  Occupational contact dermatitis in 2 dental technicians , 1990, Contact dermatitis.

[31]  S. Fregert,et al.  Patch testing with low molecular oligomers of epoxy resins in humans , 1977, Contact dermatitis.