Impact of large x-ray beam collimation on image quality

Large X-ray beam collimation in computed tomography (CT) opens the way to new image acquisition techniques and improves patient management for several clinical indications. The systems that offer large X-ray beam collimation enable, in particular, a whole region of interest to be investigated with an excellent temporal resolution. However, one of the potential drawbacks of this option might be a noticeable difference in image quality along the z-axis when compared with the standard helical acquisition mode using more restricted X-ray beam collimations. The aim of this project is to investigate the impact of the use of large X-ray beam collimation and new iterative reconstruction on noise properties, spatial resolution and low contrast detectability (LCD). An anthropomorphic phantom and a custom made phantom were scanned on a GE Revolution CT. The images were reconstructed respectively with ASIR-V at 0% and 50%. Noise power spectra, to evaluate the noise properties, and Target Transfer Functions, to evaluate the spatial resolution, were computed. Then, a Channelized Hotelling Observer with Gabor and Dense Difference of Gaussian channels was used to evaluate the LCD using the Percentage correct as a figure of merit. Noticeable differences of 3D noise power spectra and MTF have been recorded; however no significant difference appeared when dealing with the LCD criteria. As expected the use of iterative reconstruction, for a given CTDIvol level, allowed a significant gain in LCD in comparison to ASIR-V 0%. In addition, the outcomes of the NPS and TTF metrics led to results that would contradict the outcomes of CHO model observers if used for a NPWE model observer (Non- Prewhitening With Eye filter). The unit investigated provides major advantages for cardiac diagnosis without impairing the image quality level of standard chest or abdominal acquisitions.

[1]  S. T. Buckland,et al.  An Introduction to the Bootstrap. , 1994 .

[2]  Jovan G Brankov,et al.  Evaluation of the channelized Hotelling observer with an internal-noise model in a train-test paradigm for cardiac SPECT defect detection , 2013, Physics in medicine and biology.

[3]  Kyle J Myers,et al.  Task-based measures of image quality and their relation to radiation dose and patient risk , 2015, Physics in medicine and biology.

[4]  François O Bochud,et al.  Effects of computing parameters and measurement locations on the estimation of 3D NPS in non-stationary MDCT images. , 2013, Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics.

[5]  Christoph Hoeschen,et al.  Signal detection and location-dependent noise in cone-beam computed tomography using the spatial definition of the Hotelling SNR. , 2012, Medical physics.

[6]  Miguel P Eckstein,et al.  Evaluation of internal noise methods for Hotelling observer models. , 2007, Medical physics.

[7]  Fabio Becce,et al.  Update on the non-prewhitening model observer in computed tomography for the assessment of the adaptive statistical and model-based iterative reconstruction algorithms , 2014, Physics in medicine and biology.

[8]  F O Bochud,et al.  Image quality in CT: From physical measurements to model observers. , 2015, Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics.

[9]  Francis R Verdun,et al.  Iterative reconstruction methods in two different MDCT scanners: physical metrics and 4-alternative forced-choice detectability experiments--a phantom approach. , 2013, Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics.

[10]  J Y Vaishnav,et al.  Objective assessment of image quality and dose reduction in CT iterative reconstruction. , 2014, Medical physics.

[11]  H H Barrett,et al.  Human- and model-observer performance in ramp-spectrum noise: effects of regularization and object variability. , 2001, Journal of the Optical Society of America. A, Optics, image science, and vision.