압전진동자의 우주부품 활용에 관한 연구
暂无分享,去创建一个
All spacecraft components shall be checked for compatibility with vacuum using CVCM and TML in advance. CVCM and TML of the PZT-5 piezoelectric vibrator has to be less than 0.1% and 1.0% respectively. Also, it has less than 500ng/cm²/hr of TQCM for vacuum bake-out test using high temperature and high vacuum. Thus, the piezoelectric vibrator may be employed in the vacuum environments. Finally, it can be confirmed that the characteristics change of the piezoelectric vibrator is less than 1% under vacuum environments. Also, the temperature dependency of the characteristics in the PZT-5 piezoelectric vibrator with the lateral mode was investigated in the range of -100℃ to 90℃ using the thermal vacuum chamber to utilize the vibrator to the aerospace industries. As the results, at room temperature, the resonant and anti-resonant frequencies had the minimum value, whereas, the dielectric constant increased linearly from about 2500 to 7500 in the given temperature range. The mechanical loss decreased linearly from 0.08 to 0.03.