CMOS equivalent time sampling of Gaussian monocycle pulse for confocal imaging

CMOS 102.4 GS/s equivalent time sampling (ETS) circuits with a track and hold, phase-locked loop and analog to digital converter was developed for radar-based breast cancer detection. The track and hold circuits of the ETS covered the bandwidth of 2.9-13.9 GHz by use of a 1.27 nH series inductor to compensate parasitic capacitances. The pulse width and the bandwidth of the input Gaussian monocycle pulse (GMP) were 107 ps and 4.45-15.8 GHz, respectively. The received GMP waveforms by 4 × 4 antenna array were converted to 4-bit digital codes. A three dimensional confocal imaging of a 20 × 20 mm2 target in a homogeneous breast phantom was demonstrated.

[1]  P. K. Saha,et al.  Gaussian Monocycle Pulse Transmitter Using 0.18 $\mu{\hbox {m}}$ CMOS Technology With On-Chip Integrated Antennas for Inter-Chip UWB Communication , 2008, IEEE Journal of Solid-State Circuits.

[2]  R. W. Lau,et al.  The dielectric properties of biological tissues: III. Parametric models for the dielectric spectrum of tissues. , 1996, Physics in medicine and biology.

[3]  Xia Xiao,et al.  Three-dimensional confocal imaging for breast cancer detection using CMOS Gaussian monocycle pulse transmitter and 4 × 4 ultra wideband antenna array with impedance matching layer , 2014 .

[4]  M. Lindstrom,et al.  A large-scale study of the ultrawideband microwave dielectric properties of normal breast tissue obtained from reduction surgeries , 2007, Physics in medicine and biology.

[5]  Ian J Craddock,et al.  Microwave Radar-Based Differential Breast Cancer Imaging: Imaging in Homogeneous Breast Phantoms and Low Contrast Scenarios , 2010, IEEE Transactions on Antennas and Propagation.

[6]  R. W. Lau,et al.  The dielectric properties of biological tissues: II. Measurements in the frequency range 10 Hz to 20 GHz. , 1996, Physics in medicine and biology.

[7]  T. Kikkawa,et al.  A Single-Chip Ultra-Wideband Receiver With Silicon Integrated Antennas for Inter-Chip Wireless Interconnection , 2009, IEEE Journal of Solid-State Circuits.

[8]  M. Lindstrom,et al.  A large-scale study of the ultrawideband microwave dielectric properties of normal, benign and malignant breast tissues obtained from cancer surgeries , 2007, Physics in medicine and biology.

[9]  Xia Xiao,et al.  A Compact 4 $\times$ 4 Planar UWB Antenna Array for 3-D Breast Cancer Detection , 2013, IEEE Antennas and Wireless Propagation Letters.

[10]  Takamaro Kikkawa,et al.  125 mW 102.4 GS/s Ultra-High-Speed Sampling Circuit for Complementary Metal–Oxide–Semiconductor Breast Cancer Detection System , 2013 .

[11]  Paul M. Meaney,et al.  A clinical prototype for active microwave imaging of the breast , 2000 .

[12]  A. Taflove,et al.  Two-dimensional FDTD analysis of a pulsed microwave confocal system for breast cancer detection: fixed-focus and antenna-array sensors , 1998, IEEE Transactions on Biomedical Engineering.

[13]  W. Marsden I and J , 2012 .

[14]  S.C. Hagness,et al.  A confocal microwave imaging algorithm for breast cancer detection , 2001, IEEE Microwave and Wireless Components Letters.

[15]  Paul M. Meaney,et al.  Enhancing breast tumor detection with near-field imaging , 2002 .