Evaluation of a foot-to-foot impedance meter measuring extracellular fluid volume in addition to fat-free mass and fat tissue mass.
暂无分享,去创建一个
[1] K J Ellis,et al. Human hydrometry: comparison of multifrequency bioelectrical impedance with 2H2O and bromine dilution. , 1998, Journal of applied physiology.
[2] Robert F Kushner,et al. Bipedal bioelectrical impedance analysis reproducibly estimates total body water in hemodialysis patients. , 2002, American journal of kidney diseases : the official journal of the National Kidney Foundation.
[3] Y. Boirie,et al. Evaluation of two foot-to-foot bioelectrical impedance analysers to assess body composition in overweight and obese adolescents , 2003, British Journal of Nutrition.
[4] Marianne Fenech,et al. Extracellular and intracellular volume variations during postural change measured by segmental and wrist-ankle bioimpedance spectroscopy , 2004, IEEE Transactions on Biomedical Engineering.
[5] Marianne Fenech,et al. Continuous Monitoring of Plasma, Interstitial, and Intracellular Fluid Volumes in Dialyzed Patients by Bioimpedance and Hematocrit Measurements , 2002, ASAIO journal.
[6] S B Heymsfield,et al. Bioimpedance analysis: evaluation of leg-to-leg system based on pressure contact footpad electrodes. , 1997, Medicine and science in sports and exercise.
[7] A. Ward,et al. Use of the leg-to-leg bioelectrical impedance method in assessing body-composition change in obese women. , 1999, The American journal of clinical nutrition.
[8] L C Ward,et al. Bioimpedance spectrometry in the determination of body water compartments: accuracy and clinical significance. , 1998, Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine.
[9] C. Pichard,et al. Single prediction equation for bioelectrical impedance analysis in adults aged 20--94 years. , 2001, Nutrition.
[10] S A Jebb,et al. Evaluation of the novel Tanita body-fat analyser to measure body composition by comparison with a four-compartment model. , 2000, The British journal of nutrition.
[11] P. Watson,et al. Total body water volumes for adult males and females estimated from simple anthropometric measurements. , 1980, The American journal of clinical nutrition.
[12] Y. M. Dupertuis,et al. Place de l'impédancemétrie dans le dépistage de la dénutrition à l'hôpital , 2003 .
[13] J. Matthie,et al. Predicting body cell mass with bioimpedance by using theoretical methods: a technological review. , 1997, Journal of applied physiology.
[14] G. King,et al. Evaluation of a foot-to-foot bioelectrical impedance analyser in highly active, moderately active and less active young men. , 2002, The British journal of nutrition.
[15] N. Levin,et al. Dynamics of segmental extracellular volumes during changes in body position by bioimpedance analysis. , 1998, Journal of applied physiology.
[16] J. Matthie,et al. Use of bioimpedance spectroscopy to determine extracellular fluid, intracellular fluid, total body water, and fat-free mass. , 1993, Basic life sciences.