Evaluation of a foot-to-foot impedance meter measuring extracellular fluid volume in addition to fat-free mass and fat tissue mass.

OBJECTIVES The first objective was to compare the accuracy of a foot-to-foot impedance meter with a multifrequency bioimpedance for measurements of fat-free mass (FFM) and fat mass (FM) using dual energy X-ray absorptiometry (DXA) as reference. The second objective was to validate measurements of extracellular water resistance and volume by the foot-to-foot impedance meter, using multifrequency bioimpedance as reference. METHODS This investigation was carried out in 60 volunteers 18 to 71 y of age. Impedance meters were a Tefal Bodymaster Vision (foot-to-foot) that featured a square wave signal and a Xitron Hydra 4200 (5 to 1000 kHz) by using the bioimpedance spectroscopic method. RESULTS Bland-Altman tests showed that FFM differences between Tefal and DXA data were 1.98 +/- 3.09 kg in men and -0.08+/-2.98 kg in women. Total body water was measured by the Xitron, and FFM as measured with the Xitron was calculated as total body water divided by 0.732. Mean differences between Xitron-measured and DXA-measured FFM were 2.37+/-3.03 kg for men and 2.84+/-2.40 kg for women, indicating a systematic underestimation by the Xitron of intracellular volume. Extracellular water resistances measured by Tefal were in good agreement with those measured by Xitron with electrodes pasted under the subject's feet (mean difference 8.5+/-31 Omega). Extracellular water volumes were calculated from Tefal-measured extracellular water resistances by using a modified bioimpedance spectroscopic method and differed from those measured with Xitron by-0.03+/-0.66 L. CONCLUSION Limits of agreement with DXA-measured FFM produced by the foot-to-foot impedance meter tested are too large for clinical measurements in individuals, but they are sufficient to assess FFM in groups of subjects and for home use. Our prototype was also capable of estimating extracellular water volume with a similar accuracy as multifrequency bioimpedance in normal subjects.

[1]  K J Ellis,et al.  Human hydrometry: comparison of multifrequency bioelectrical impedance with 2H2O and bromine dilution. , 1998, Journal of applied physiology.

[2]  Robert F Kushner,et al.  Bipedal bioelectrical impedance analysis reproducibly estimates total body water in hemodialysis patients. , 2002, American journal of kidney diseases : the official journal of the National Kidney Foundation.

[3]  Y. Boirie,et al.  Evaluation of two foot-to-foot bioelectrical impedance analysers to assess body composition in overweight and obese adolescents , 2003, British Journal of Nutrition.

[4]  Marianne Fenech,et al.  Extracellular and intracellular volume variations during postural change measured by segmental and wrist-ankle bioimpedance spectroscopy , 2004, IEEE Transactions on Biomedical Engineering.

[5]  Marianne Fenech,et al.  Continuous Monitoring of Plasma, Interstitial, and Intracellular Fluid Volumes in Dialyzed Patients by Bioimpedance and Hematocrit Measurements , 2002, ASAIO journal.

[6]  S B Heymsfield,et al.  Bioimpedance analysis: evaluation of leg-to-leg system based on pressure contact footpad electrodes. , 1997, Medicine and science in sports and exercise.

[7]  A. Ward,et al.  Use of the leg-to-leg bioelectrical impedance method in assessing body-composition change in obese women. , 1999, The American journal of clinical nutrition.

[8]  L C Ward,et al.  Bioimpedance spectrometry in the determination of body water compartments: accuracy and clinical significance. , 1998, Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine.

[9]  C. Pichard,et al.  Single prediction equation for bioelectrical impedance analysis in adults aged 20--94 years. , 2001, Nutrition.

[10]  S A Jebb,et al.  Evaluation of the novel Tanita body-fat analyser to measure body composition by comparison with a four-compartment model. , 2000, The British journal of nutrition.

[11]  P. Watson,et al.  Total body water volumes for adult males and females estimated from simple anthropometric measurements. , 1980, The American journal of clinical nutrition.

[12]  Y. M. Dupertuis,et al.  Place de l'impédancemétrie dans le dépistage de la dénutrition à l'hôpital , 2003 .

[13]  J. Matthie,et al.  Predicting body cell mass with bioimpedance by using theoretical methods: a technological review. , 1997, Journal of applied physiology.

[14]  G. King,et al.  Evaluation of a foot-to-foot bioelectrical impedance analyser in highly active, moderately active and less active young men. , 2002, The British journal of nutrition.

[15]  N. Levin,et al.  Dynamics of segmental extracellular volumes during changes in body position by bioimpedance analysis. , 1998, Journal of applied physiology.

[16]  J. Matthie,et al.  Use of bioimpedance spectroscopy to determine extracellular fluid, intracellular fluid, total body water, and fat-free mass. , 1993, Basic life sciences.