Exergetic and thermo-ecological assessment of heat pump supported by electricity from renewable sources

Abstract Heat pumps (HP) represent an attractive option as a heat source, since they utilise “free” ambient heat. However, as they need to be driven by electric energy, their ecological efficiency depends not only on their performance, but also on the energy mix used for electricity generation. Effectiveness of HP can be improved by applying renewable energy sources (RES) providing electricity to drive the system. In order to properly assess such a system, it should be evaluated within a global balance boundary reaching the level of primary resources. The authors propose the use of thermo-ecological cost (TEC) indices for exergo-ecological assessment. TEC is defined as cumulative consumption of non-renewable exergy connected with the fabrication of a particular product. TEC also includes additional consumption of non-renewable natural resources which results from the necessity of compensating environmental losses caused by rejection of harmful substances to the environment. Within the paper, a HP system has been analysed from the ecological point of view. The system consists of a heat pump driven by electricity, and photovoltaic panels or wind turbines as a basic source of electricity. The balance of electricity demand for HP is complemented by electricity from grid. To evaluate this system, real environmental data on solar radiation, wind and ambient temperature deciding on heat demand have been taken into account. The authors present the ecological benefits resulting from supporting heat pumps by electricity generated in RES. It has been demonstrated by comparing results obtained within local and global balance boundaries, that the second approach should be consequently applied when systems based on a mix of renewable and non-renewable energy are analysed, since the first approach may lead to misleading conclusions.

[1]  Xing Zhang,et al.  Performance analysis of a rooftop wind solar hybrid heat pump system for buildings , 2013 .

[2]  S. P. Lohani,et al.  Comparison of energy and exergy analysis of fossil plant, ground and air source heat pump building heating system , 2010 .

[3]  Antonio Valero Exergy accounting: Capabilities and drawbacks , 2006 .

[4]  Ryozo Ooka,et al.  Exergy analysis of a hybrid ground-source heat pump system , 2017 .

[5]  Wojciech Stanek,et al.  Depletion of the non-renewable natural exergy resources as a measure of the ecological cost , 2002 .

[6]  Wojciech Stanek Examples of Application of Exergy Analysis for the Evaluation of Ecological Effects in Thermal Processes , 2012 .

[7]  Hailong Li,et al.  Dynamic performance of the standalone wind power driven heat pump , 2016 .

[8]  Xiaohua Xia,et al.  Optimal control of a wind–PV-hybrid powered heat pump water heater , 2017 .

[9]  Antonio Valero,et al.  Thermoeconomic tools for the analysis of eco-industrial parks , 2013 .

[10]  Wiesław Gazda,et al.  Thermo-ecological cost of electricity from renewable energy sources , 2016 .

[11]  Cristian Chiavetta,et al.  Comparative life cycle assessment of renewable energy systems for heating and cooling , 2011 .

[12]  V. V. Kharchenko,et al.  The heat supply system for a self-contained dwelling house on the basis of a heat pump and wind power installation , 2013 .

[13]  Ibrahim Dincer,et al.  Techno-economic assessment of a renewable energy based integrated multigeneration system for green buildings , 2016 .

[14]  Wiesław Gazda,et al.  Thermo-ecological assessment of CCHP (combined cold-heat-and-power) plant supported with renewable energy , 2015 .

[15]  Olcay Kincay,et al.  Exergy, exergoenvironmental and exergoeconomic evaluation of a heat pump-integrated wall heating system , 2016 .

[16]  Christopher J. Koroneos,et al.  Exergy analysis of renewable energy sources , 2003 .

[17]  Jan Szargut Analysis of cumulative exergy consumption , 1987 .

[18]  Onder Ozgener,et al.  Use of solar assisted geothermal heat pump and small wind turbine systems for heating agricultural and residential buildings , 2010 .