Application of computer-aided design and 3D-printed navigation template in Locking Compression Pediatric Hip Plate$$^{\mathrm{TM}}$$TM placement for pediatric hip disease

BackgroundTo investigate the feasibility and accuracy of a drill template based on computer-aided design (CAD) and 3D printing technology for the placement of screws in Locking Compression Pediatric Hip Plate (LCP-PHP).MethodsLCP-PHP was used in 11 children [5 with femoral neck fracture and 6 with development dysplasia of hip (DDH)]. Using the CT data, the proximal femur model was created by a 3D printer. Fracture reduction and the placement of the screw in the femoral neck and the LCP-PHP were simulated by the computer. The navigation template was designed by the software to match the proximal femur. After the feasibility of the 3D model operation was demonstrated before the operation, the guide pins and the screws were inserted with the help of the navigate template in the operation.ResultsDuring surgery, the navigation template for each case was matched to the bony markers of the proximal femur. With the help of the template, in femoral neck fracture cases, three screws could be accurately inserted into the femoral neck to implant the LCP-PHP and stabilize the fracture. The template for DDH includes all operation parameters and steps for proximal femoral varus rotation and shortening osteotomy, which made the surgery much easier to perform. Radiographs taken after surgery showed that the postoperative results closely corresponded to the preoperative computer simulation. The average time taken for LCP-PHP placement was 26.5 min; radiography was used during surgery only for an average of 6.0 times. Postoperative radiographs showed good results.ConclusionWith the use of CAD and 3D printing technology, accurate placement of individualized navigation template of LCP-PHP can be achieved. This technology can reduce intraoperative damage to the femoral neck epiphysis, decrease operation time, reduce intraoperative hemorrhage, and decrease radiation exposure to patients and personnel during the surgery.

[1]  Randy E. Ellis,et al.  The influence of osteophyte depiction in CT for patient-specific guided hip resurfacing procedures , 2015, International Journal of Computer Assisted Radiology and Surgery.

[2]  H. Kerr Graham,et al.  Cannulated, locking blade plates for proximal femoral osteotomy in children and adolescents , 2015, Journal of children's orthopaedics.

[3]  J Poul,et al.  [Accuracy of proximal femur correction achieved with LCP paediatric hip plates]. , 2013, Acta chirurgiae orthopaedicae et traumatologiae Cechoslovaca.

[4]  S. Kokubun,et al.  Avascular necrosis associated with fractures of the femoral neck in children: histological evaluation of core biopsies of the femoral head. , 2003, Injury.

[5]  Hui Zhao,et al.  A novel navigation template for fixation of acetabular posterior column fractures with antegrade lag screws: design and application , 2016, International Orthopaedics.

[6]  Hu Long,et al.  The Accuracy of Computer Image-Guided Template for Mandibular Angle Ostectomy , 2015, Aesthetic Plastic Surgery.

[7]  V. Kapoor,et al.  Avascular necrosis associated with fractures of the femoral neck in children: histological evaluation of core biopsies of the femoral head. , 2005, Injury.

[8]  R. Liu,et al.  Preliminary application of computer‐assisted patient‐specific acetabular navigational template for total hip arthroplasty in adult single development dysplasia of the hip , 2011, The international journal of medical robotics + computer assisted surgery : MRCAS.

[9]  Alexander Joeris,et al.  The Locking Compression Paediatric Hip Plate™: technical guide and critical analysis , 2012, International Orthopaedics.

[10]  N. Sugano,et al.  Tailor-made Surgical Guide Reduces Incidence of Outliers of Cup Placement , 2010, Clinical orthopaedics and related research.

[11]  赵国强,et al.  小儿髋部锁定加压接骨板治疗儿童股骨粗隆部骨折 , 2013 .

[12]  F Gelaude,et al.  A custom-made guide for femoral component positioning in hip resurfacing arthroplasty: development and validation study , 2011, Computer aided surgery : official journal of the International Society for Computer Aided Surgery.

[13]  Fan Zhang,et al.  [A cadaveric study on establishing an individualized navigation template for the placement of occipital condyle screws using a three-dimensional printing technique]. , 2014, Zhonghua wai ke za zhi [Chinese journal of surgery].

[14]  L. Ramseier,et al.  LCP 140° Pediatric Hip Plate for fixation of proximal femoral valgisation osteotomy , 2014, Journal of children's orthopaedics.

[15]  Taku Sugawara,et al.  Safe and Accurate Midcervical Pedicle Screw Insertion Procedure With the Patient-Specific Screw Guide Template System , 2015, Spine.

[16]  Michael P Glotzbecker,et al.  Osteonecrosis After Femoral Neck Fractures in Children and Adolescents: Analysis of Risk Factors , 2016, Journal of pediatric orthopedics.

[17]  R. Ellis,et al.  Computer-assisted hip resurfacing using individualized drill templates. , 2010, The Journal of arthroplasty.