Optical frequency domain imaging of ex vivo pulmonary resection specimens: obtaining one to one image to histopathology correlation.

Lung cancer is the leading cause of cancer-related deaths. Squamous cell and small cell cancers typically arise in association with the conducting airways, whereas adenocarcinomas are typically more peripheral in location. Lung malignancy detection early in the disease process may be difficult due to several limitations: radiological resolution, bronchoscopic limitations in evaluating tissue underlying the airway mucosa and identifying early pathologic changes, and small sample size and/or incomplete sampling in histology biopsies. High resolution imaging modalities, such as optical frequency domain imaging (OFDI), provide non-destructive, large area 3-dimensional views of tissue microstructure to depths approaching 2 mm in real time (Figure 1). OFDI has been utilized in a variety of applications, including evaluation of coronary artery atherosclerosis and esophageal intestinal metaplasia and dysplasia. Bronchoscopic OCT/OFDI has been demonstrated as a safe in vivo imaging tool for evaluating the pulmonary airways (Animation). OCT has been assessed in pulmonary airways and parenchyma of animal models and in vivo human airway. OCT imaging of normal airway has demonstrated visualization of airway layering and alveolar attachments, and evaluation of dysplastic lesions has been found useful in distinguishing grades of dysplasia in the bronchial mucosa. OFDI imaging of bronchial mucosa has been demonstrated in a short bronchial segment (0.8 cm). Additionally, volumetric OFDI spanning multiple airway generations in swine and human pulmonary airways in vivo has been described. Endobronchial OCT/OFDI is typically performed using thin, flexible catheters, which are compatible with standard bronchoscopic access ports. Additionally, OCT and OFDI needle-based probes have recently been developed, which may be used to image regions of the lung beyond the airway wall or pleural surface. While OCT/OFDI has been utilized and demonstrated as feasible for in vivo pulmonary imaging, no studies with precisely matched one-to-one OFDI:histology have been performed. Therefore, specific imaging criteria for various pulmonary pathologies have yet to be developed. Histopathological counterparts obtained in vivo consist of only small biopsy fragments, which are difficult to correlate with large OFDI datasets. Additionally, they do not provide the comprehensive histology needed for registration with large volume OFDI. As a result, specific imaging features of pulmonary pathology cannot be developed in the in vivo setting. Precisely matched, one-to-one OFDI and histology correlation is vital to accurately evaluate features seen in OFDI against histology as a gold standard in order to derive specific image interpretation criteria for pulmonary neoplasms and other pulmonary pathologies. Once specific imaging criteria have been developed and validated ex vivo with matched one-to-one histology, the criteria may then be applied to in vivo imaging studies. Here, we present a method for precise, one to one correlation between high resolution optical imaging and histology in ex vivo lung resection specimens. Throughout this manuscript, we describe the techniques used to match OFDI images to histology. However, this method is not specific to OFDI and can be used to obtain histology-registered images for any optical imaging technique. We performed airway centered OFDI with a specialized custom built bronchoscopic 2.4 French (0.8 mm diameter) catheter. Tissue samples were marked with tissue dye, visible in both OFDI and histology. Careful orientation procedures were used to precisely correlate imaging and histological sampling locations. The techniques outlined in this manuscript were used to conduct the first demonstration of volumetric OFDI with precise correlation to tissue-based diagnosis for evaluating pulmonary pathology. This straightforward, effective technique may be extended to other tissue types to provide precise imaging to histology correlation needed to determine fine imaging features of both normal and diseased tissues.

[1]  Mari Mino-Kenudson,et al.  Volumetric optical frequency domain imaging of pulmonary pathology with precise correlation to histopathology. , 2013, Chest.

[2]  J. D. de Boer,et al.  Phase-stabilized optical frequency domain imaging at 1-µm for the measurement of blood flow in the human choroid. , 2011, Optics Express.

[3]  David D Sampson,et al.  In situ imaging of lung alveoli with an optical coherence tomography needle probe. , 2011, Journal of biomedical optics.

[4]  A. Saftoiu,et al.  Optical coherence tomography and Doppler optical coherence tomography in the gastrointestinal tract. , 2011, World journal of gastroenterology.

[5]  Kar-Ming Fung,et al.  Optical coherence tomography as an adjunct to flexible bronchoscopy in the diagnosis of lung cancer: a pilot study. , 2010, Chest.

[6]  B. Vakoc,et al.  >400 kHz repetition rate wavelength-swept laser and application to high-speed optical frequency domain imaging. , 2010, Optics letters.

[7]  M. Mino‐Kenudson,et al.  Real-time Comprehensive Microscopy Of The Pulmonary Airways: A Pilot Clinical Study , 2010, Asian Test Symposium.

[8]  Benjamin J Vakoc,et al.  Image-guided biopsy in the esophagus through comprehensive optical frequency domain imaging and laser marking: a study in living swine. , 2010, Gastrointestinal endoscopy.

[9]  Gangjun Liu,et al.  In vivo three-dimensional imaging of normal tissue and tumors in the rabbit pleural cavity using endoscopic swept source optical coherence tomography with thoracoscopic guidance. , 2009, Journal of biomedical optics.

[10]  M. Wojtkowski,et al.  Ultra high-speed swept source OCT imaging of the anterior segment of human eye at 200 kHz with adjustable imaging range. , 2009, Optics express.

[11]  Stephen Lam,et al.  Quantitative assessment of the airway wall using computed tomography and optical coherence tomography. , 2009, Proceedings of the American Thoracic Society.

[12]  David D Sampson,et al.  Using optical coherence tomography to improve diagnostic and therapeutic bronchoscopy. , 2009, Chest.

[13]  Benjamin J Vakoc,et al.  Three-dimensional coronary artery microscopy by intracoronary optical frequency domain imaging. , 2008, JACC. Cardiovascular imaging.

[14]  Benjamin J Vakoc,et al.  Comprehensive microscopy of the esophagus in human patients with optical frequency domain imaging. , 2008, Gastrointestinal endoscopy.

[15]  Stephen Lam,et al.  Airway wall thickness assessed using computed tomography and optical coherence tomography. , 2008, American journal of respiratory and critical care medicine.

[16]  Matthew Brenner,et al.  Real-time swept source optical coherence tomography imaging of the human airway using a microelectromechanical system endoscope and digital signal processor. , 2008, Journal of biomedical optics.

[17]  Calum MacAulay,et al.  In vivo Optical Coherence Tomography Imaging of Preinvasive Bronchial Lesions , 2008, Clinical Cancer Research.

[18]  B. Vakoc,et al.  Angle-resolved optical coherence tomography with sequential angular selectivity for speckle reduction. , 2007, Optics express.

[19]  John A. Evans,et al.  Comprehensive volumetric optical microscopy in vivo , 2006, Nature Medicine.

[20]  Suzanne C. Whiteman,et al.  Optical Coherence Tomography: Real-time Imaging of Bronchial Airways Microstructure and Detection of Inflammatory/Neoplastic Morphologic Changes , 2006, Clinical Cancer Research.

[21]  H. Kato,et al.  Optical coherence tomography in the diagnosis of bronchial lesions. , 2005, Lung cancer.

[22]  Victor X D Yang,et al.  Endoscopic Doppler optical coherence tomography in the human GI tract: initial experience. , 2005, Gastrointestinal endoscopy.

[23]  H. Colt,et al.  Two-dimensional and 3-dimensional optical coherence tomographic imaging of the airway, lung, and pleura. , 2005, The Journal of thoracic and cardiovascular surgery.

[24]  S. Yun,et al.  Removing the depth-degeneracy in optical frequency domain imaging with frequency shifting. , 2004, Optics express.

[25]  Yonghong He,et al.  Use of optical coherence tomography in delineating airways microstructure: comparison of OCT images to histopathological sections , 2004, Physics in medicine and biology.

[26]  S. Yun,et al.  High-speed optical frequency-domain imaging. , 2003, Optics express.

[27]  C. Baird,et al.  The pilot study. , 2000, Orthopedic nursing.

[28]  M. V. van Gemert,et al.  Noninvasive imaging of in vivo blood flow velocity using optical Doppler tomography. , 1997, Optics letters.

[29]  J. Fujimoto,et al.  In vivo endoscopic optical biopsy with optical coherence tomography. , 1997, Science.

[30]  J. Fujimoto,et al.  Optical biopsy and imaging using optical coherence tomography , 1995, Nature Medicine.

[31]  N. Dubrawsky Cancer statistics , 1989, CA: a cancer journal for clinicians.