Predictive prosthetic socket design: part 1—population-based evaluation of transtibial prosthetic sockets by FEA-driven surrogate modelling

It has been proposed that finite element analysis can complement clinical decision making for the appropriate design and manufacture of prosthetic sockets for amputees. However, clinical translation has not been achieved, in part due to lengthy solver times and the complexity involved in model development. In this study, a parametric model was created, informed by variation in (i) population-driven residuum shape morphology, (ii) soft tissue compliance and (iii) prosthetic socket design. A Kriging surrogate model was fitted to the response of the analyses across the design space enabling prediction for new residual limb morphologies and socket designs. It was predicted that morphological variability and prosthetic socket design had a substantial effect on socket-limb interfacial pressure and shear conditions as well as sub-dermal soft tissue strains. These relationships were investigated with a higher resolution of anatomical, surgical and design variability than previously reported, with a reduction in computational expense of six orders of magnitude. This enabled real-time predictions (1.6 ms) with error vs the analytical solutions of < 4 kPa in pressure at residuum tip, and < 3% in soft tissue strain. As such, this framework represents a substantial step towards implementation of finite element analysis in the prosthetics clinic.

[1]  Caterina Rizzi,et al.  A digital patient for computer-aided prosthesis design , 2013, Interface Focus.

[2]  Matthew P Reed,et al.  Development and Validation of a High Anatomical Fidelity FE Model for the Buttock and Thigh of a Seated Individual , 2016, Annals of Biomedical Engineering.

[3]  Prasanth B. Nair,et al.  Statistical modelling of the whole human femur incorporating geometric and material properties. , 2010, Medical engineering & physics.

[4]  Andy J. Keane,et al.  Engineering Design via Surrogate Modelling - A Practical Guide , 2008 .

[5]  E. Zimerson,et al.  Skin disorders in amputees. , 2000, Journal of the American Academy of Dermatology.

[6]  D G Smith,et al.  Transtibial amputations. , 1999, Clinical orthopaedics and related research.

[7]  Ming Zhang,et al.  Pressure distribution at the stump/socket interface in transtibial amputees during walking on stairs, slope and non-flat road. , 2006, Clinical Biomechanics.

[8]  Amit Gefen,et al.  Stress relaxation of porcine gluteus muscle subjected to sudden transverse deformation as related to pressure sore modeling. , 2006, Journal of biomechanical engineering.

[9]  A Gefen,et al.  Patient-specific analyses of deep tissue loads post transtibial amputation in residual limbs of multiple prosthetic users. , 2009, Journal of biomechanics.

[10]  Neil W. Bressloff,et al.  Multi-objective optimisation of stent dilation strategy in a patient-specific coronary artery via computational and surrogate modelling. , 2016, Journal of biomechanics.

[11]  Joan E Sanders,et al.  Shape and volume change in the transtibial residuum over the short term: preliminary investigation of six subjects. , 2004, Journal of rehabilitation research and development.

[12]  Peter R Worsley,et al.  Registering methodology for imaging and analysis of residual-limb shape after transtibial amputation. , 2016, Journal of rehabilitation research and development.

[13]  P J Holliday,et al.  Volume fluctuations in the residual limbs of lower limb amputees. , 1982, Archives of physical medicine and rehabilitation.

[14]  Tb. Staats The UCLA total surface bearing suction below-knee prosthesis , 1987 .

[15]  Per G. Reinhall,et al.  A finite element model to assess transtibial prosthetic sockets with elastomeric liners , 2017, Medical & Biological Engineering & Computing.

[16]  Arianna Menciassi,et al.  Sockets for Limb Prostheses: A Review of Existing Technologies and Open Challenges , 2018, IEEE Transactions on Biomedical Engineering.

[17]  Hugh Herr,et al.  Multi-Indenter Device for in Vivo Biomechanical Tissue Measurement , 2017, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[18]  J Foort,et al.  Computer aided design of prosthetic sockets for below-knee amputees , 1985, Prosthetics and orthotics international.

[19]  Chris Paulson,et al.  pyKriging: A Python Kriging Toolkit , 2015 .

[20]  Xiaohong Jia,et al.  Finite element modeling of the contact interface between trans-tibial residual limb and prosthetic socket. , 2004, Medical engineering & physics.

[21]  H. Watts,et al.  Outcomes of Lengthening Short Lower-Extremity Amputation Stumps With Planar Fixators , 2005, Journal of pediatric orthopedics.

[22]  D. Bader,et al.  Development of a residuum/socket interface simulator for lower limb prosthetics , 2017, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[23]  I. Siev-Ner,et al.  Surgical and Morphological Factors that Affect Internal Mechanical Loads in Soft Tissues of the Transtibial Residuum , 2009, Annals of Biomedical Engineering.

[24]  Dan L. Bader,et al.  Characterisation of dynamic couplings at lower limb residuum/socket interface using 3D motion capture. , 2015, Medical engineering & physics.

[25]  B. Persson,et al.  Measurement of maximal end-weight-bearing in lower limb amputees , 1982, Prosthetics and orthotics international.

[26]  Frank Baaijens,et al.  Pressure Induced Deep Tissue Injury Explained , 2014, Annals of Biomedical Engineering.

[27]  Yohan Payan,et al.  Personalized modeling for real-time pressure ulcer prevention in sitting posture. , 2018, Journal of tissue viability.

[28]  Mark Taylor,et al.  Four decades of finite element analysis of orthopaedic devices: where are we now and what are the opportunities? , 2015, Journal of biomechanics.

[29]  P. Nair,et al.  A large scale finite element study of a cementless osseointegrated tibial tray. , 2013, Journal of biomechanics.

[30]  Ellen J Mackenzie,et al.  Use and satisfaction with prosthetic limb devices and related services. , 2004, Archives of physical medicine and rehabilitation.

[31]  D L Bader,et al.  Development and validation of a 3D-printed interfacial stress sensor for prosthetic applications. , 2015, Medical engineering & physics.

[32]  Angus McFadyen,et al.  Dynamic interface pressure distributions of two transtibial prosthetic socket concepts. , 2009, Journal of rehabilitation research and development.

[33]  Georgina Charlesworth,et al.  Core outcome measures for interventions to prevent or slow the progress of dementia for people living with mild to moderate dementia: Systematic review and consensus recommendations , 2017, PloS one.

[34]  A. Gefen,et al.  Microclimate: A critical review in the context of pressure ulcer prevention , 2018, Clinical biomechanics.

[35]  James Cho Hong Goh,et al.  Comparative study between patellar-tendon-bearing and pressure cast prosthetic sockets. , 2004, Journal of rehabilitation research and development.

[36]  Miguel Ángel Martínez,et al.  A three-dimensional finite element analysis of the combined behavior of ligaments and menisci in the healthy human knee joint. , 2006, Journal of biomechanics.

[37]  A. Burstein,et al.  The elastic and ultimate properties of compact bone tissue. , 1975, Journal of biomechanics.

[38]  Joan E Sanders,et al.  CAD/CAM transtibial prosthetic sockets from central fabrication facilities: how accurate are they? , 2007, Journal of rehabilitation research and development.

[39]  Gianluigi Rozza,et al.  Efficient geometrical parametrisation techniques of interfaces for reduced-order modelling: application to fluid–structure interaction coupling problems , 2014 .

[40]  David J. Hawkes,et al.  Instantiation and registration of statistical shape models of the femur and pelvis using 3D ultrasound imaging , 2008, Medical Image Anal..

[41]  Dr D. P. Reynolds,et al.  Interface load analysis for computer-aided design of below-knee prosthetic sockets , 1992, Medical and Biological Engineering and Computing.

[42]  Vladimir Buljak,et al.  Proper Orthogonal Decomposition and Radial Basis Functions Algorithm for Diagnostic Procedure Based on Inverse Analysis , 2010 .

[43]  J C H Goh,et al.  Development of an integrated CAD-FEA process for below-knee prosthetic sockets. , 2005, Clinical biomechanics.

[44]  M. Sarıyıldız,et al.  Sockets Manufactured by CAD/CAM Method Have Positive Effects on the Quality of Life of Patients With Transtibial Amputation , 2017, American journal of physical medicine & rehabilitation.

[45]  Eugene Hsu,et al.  Postamputation pain: epidemiology, mechanisms, and treatment , 2013, Journal of pain research.

[46]  Joan E Sanders,et al.  Testing of elastomeric liners used in limb prosthetics: classification of 15 products by mechanical performance. , 2004, Journal of rehabilitation research and development.

[47]  Ming Zhang,et al.  Effect of alignment changes on sagittal and coronal socket reaction moment interactions in transtibial prostheses. , 2013, Journal of biomechanics.

[48]  Toshiki Kobayashi,et al.  Effect of alignment changes on socket reaction moments during gait in transfemoral and knee-disarticulation prostheses: case series. , 2013, Journal of biomechanics.

[49]  L. Nolte,et al.  Mechanical Tensile Properties of the Quadriceps Tendon and Patellar Ligament in Young Adults , 1999, The American journal of sports medicine.

[50]  J W Steer,et al.  Finite element analysis of the amputated lower limb: A systematic review and recommendations. , 2017, Medical engineering & physics.

[51]  D. Bader,et al.  A combined kinematic and kinetic analysis at the residuum/socket interface of a knee-disarticulation amputee. , 2017, Medical engineering & physics.

[52]  Hiromi Sanada,et al.  Microclimate and development of pressure ulcers and superficial skin changes , 2015, International wound journal.

[53]  M. J. Highsmith,et al.  INTERVENTIONS TO MANAGE RESIDUAL LIMB ULCERATION DUE TO PROSTHETIC USE IN INDIVIDUALS WITH LOWER EXTREMITY AMPUTATION: A SYSTEMATIC REVIEW OF THE LITERATURE. , 2016, Technology and innovation.

[54]  Timothy F. Cootes,et al.  3D Brain Segmentation Using Active Appearance Models and Local Regressors , 2008, MICCAI.

[55]  T. J. Mitchell,et al.  Exploratory designs for computational experiments , 1995 .

[56]  Koichi Shinkoda,et al.  Hygiene problems of residual limb and silicone liners in transtibial amputees wearing the total surface bearing socket. , 2001, Archives of physical medicine and rehabilitation.

[57]  Fritz Schick,et al.  An Efficient Modelling-Simulation-Analysis Workflow to Investigate Stump-Socket Interaction Using Patient-Specific, Three-Dimensional, Continuum-Mechanical, Finite Element Residual Limb Models , 2018, Front. Bioeng. Biotechnol..

[58]  Xiaohong Jia,et al.  A quasi-dynamic nonlinear finite element model to investigate prosthetic interface stresses during walking for trans-tibial amputees. , 2005, Clinical biomechanics.

[59]  Mark Taylor,et al.  Development of a statistical model of knee kinetics for applications in pre-clinical testing. , 2012, Journal of biomechanics.

[60]  C. Oomens,et al.  The effects of deformation, ischemia, and reperfusion on the development of muscle damage during prolonged loading. , 2011, Journal of applied physiology.

[61]  Martin Browne,et al.  The potential of statistical shape modelling for geometric morphometric analysis of human teeth in archaeological research , 2017, PloS one.

[62]  Jonathan Kofman,et al.  The CAPOD System — A Scandinavian CAD/CAM System for Prosthetic Sockets , 1989 .

[63]  M Zhang,et al.  Finite element modelling of a residual lower-limb in a prosthetic socket: a survey of the development in the first decade. , 1998, Medical engineering & physics.