Fibre operating lengths of human lower limb muscles during walking

Muscles actuate movement by generating forces. The forces generated by muscles are highly dependent on their fibre lengths, yet it is difficult to measure the lengths over which muscle fibres operate during movement. We combined experimental measurements of joint angles and muscle activation patterns during walking with a musculoskeletal model that captures the relationships between muscle fibre lengths, joint angles and muscle activations for muscles of the lower limb. We used this musculoskeletal model to produce a simulation of muscle–tendon dynamics during walking and calculated fibre operating lengths (i.e. the length of muscle fibres relative to their optimal fibre length) for 17 lower limb muscles. Our results indicate that when musculotendon compliance is low, the muscle fibre operating length is determined predominantly by the joint angles and muscle moment arms. If musculotendon compliance is high, muscle fibre operating length is more dependent on activation level and force–length–velocity effects. We found that muscles operate on multiple limbs of the force–length curve (i.e. ascending, plateau and descending limbs) during the gait cycle, but are active within a smaller portion of their total operating range.

[1]  H. T. ter Keurs,et al.  Effect of thin filament length on the force-sarcomere length relation of skeletal muscle. , 1991, The American journal of physiology.

[2]  Laura H. Smallwood,et al.  Are Current Measurements of Lower Extremity Muscle Architecture Accurate? , 2009, Clinical orthopaedics and related research.

[3]  T. van Eijden,et al.  Forces acting on the patella during maximal voluntary contraction of the quadriceps femoris muscle at different knee flexion/extension angles. , 1987, Acta anatomica.

[4]  W Herzog,et al.  Length dependence of active force production in skeletal muscle. , 1999, Journal of applied physiology.

[5]  A. J. van den Bogert,et al.  Human muscle modelling from a user's perspective. , 1998, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[6]  V. T. Inman The joints of the ankle , 1976 .

[7]  F. Noyes,et al.  Biomechanics of the knee-extension exercise. Effect of cutting the anterior cruciate ligament. , 1984, The Journal of bone and joint surgery. American volume.

[8]  D L Morgan,et al.  Intersarcomere dynamics during fixed‐end tetanic contractions of frog muscle fibres. , 1979, The Journal of physiology.

[9]  May Q. Liu,et al.  Muscle contributions to support and progression over a range of walking speeds. , 2008, Journal of biomechanics.

[10]  A. Cutts,et al.  The range of sarcomere lengths in the muscles of the human lower limb. , 1988, Journal of anatomy.

[11]  J. Challis,et al.  The expression of the skeletal muscle force-length relationship in vivo: a simulation study. , 2010, Journal of theoretical biology.

[12]  John H Challis,et al.  The force-length curves of the human rectus femoris and gastrocnemius muscles in vivo. , 2010, Journal of applied biomechanics.

[13]  M. Nussbaum,et al.  Maximum voluntary joint torque as a function of joint angle and angular velocity: model development and application to the lower limb. , 2007, Journal of biomechanics.

[14]  M P Kadaba,et al.  Measurement of lower extremity kinematics during level walking , 1990, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[15]  John N. Howell,et al.  In vivo Measurement of Fascicle Length and Pennation Angle of the Human Biceps femoris Muscle , 2001, Cells Tissues Organs.

[16]  J J O'Connor,et al.  Bone position estimation from skin marker co-ordinates using global optimisation with joint constraints. , 1999, Journal of biomechanics.

[17]  R L Lieber,et al.  Musculoskeletal balance of the human wrist elucidated using intraoperative laser diffraction. , 1998, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[18]  R. Griffiths Shortening of muscle fibres during stretch of the active cat medial gastrocnemius muscle: the role of tendon compliance. , 1991, The Journal of physiology.

[19]  W Herzog,et al.  Residual force enhancement in skeletal muscle , 2006, The Journal of physiology.

[20]  T. Fukunaga,et al.  Determination of fascicle length and pennation in a contracting human muscle in vivo. , 1997, Journal of applied physiology.

[21]  Claire C. Gordon,et al.  2012 Anthropometric Survey of U.S. Army Personnel: Methods and Summary Statistics , 2014 .

[22]  Scott L. Delp,et al.  A Model of the Lower Limb for Analysis of Human Movement , 2010, Annals of Biomedical Engineering.

[23]  Ayman Habib,et al.  OpenSim: Open-Source Software to Create and Analyze Dynamic Simulations of Movement , 2007, IEEE Transactions on Biomedical Engineering.

[24]  A. McComas,et al.  Influence of joint position on ankle plantarflexion in humans. , 1982, Journal of applied physiology: respiratory, environmental and exercise physiology.

[25]  A. Huxley,et al.  The variation in isometric tension with sarcomere length in vertebrate muscle fibres , 1966, The Journal of physiology.

[26]  G. C. Joyce,et al.  Isotonic lengthening and shortening movements of cat soleus muscle , 1969, The Journal of physiology.

[27]  T. Fukunaga,et al.  In vivo behaviour of human muscle tendon during walking , 2001, Proceedings of the Royal Society of London. Series B: Biological Sciences.

[28]  C. Maganaris,et al.  Force-length characteristics of in vivo human skeletal muscle. , 2001, Acta physiologica Scandinavica.

[29]  A. Bahler,et al.  The Dynamic Properties of Mammalian Skeletal Muscle , 1968, The Journal of general physiology.

[30]  S. Sepic,et al.  Strength of isometric and isokinetic contractions: knee muscles of men aged 20 to 86. , 1980, Physical therapy.

[31]  W. Herzog,et al.  Moment-length relations of rectus femoris muscles of speed skaters/cyclists and runners. , 1991, Medicine and science in sports and exercise.

[32]  E. Chao,et al.  Quantitative measurements of hip strength in different age groups. , 1989, Clinical orthopaedics and related research.

[33]  F. Zajac Muscle and tendon: properties, models, scaling, and application to biomechanics and motor control. , 1989, Critical reviews in biomedical engineering.

[34]  A S Arnold,et al.  Do the hamstrings and adductors contribute to excessive internal rotation of the hip in persons with cerebral palsy? , 2000, Gait & posture.

[35]  W. Herzog,et al.  A comparison of knee extensor strength curves obtained theoretically and experimentally. , 1991, Medicine and science in sports and exercise.

[36]  John T. McConville,et al.  Anthropometric Survey of U.S. Army Personnel: Methods and Summary Statistics 1988 , 1989 .

[37]  U Proske,et al.  Tendon stiffness: methods of measurement and significance for the control of movement. A review. , 1987, Journal of biomechanics.

[38]  A Cutts Sarcomere length changes in muscles of the human thigh during walking. , 1989, Journal of anatomy.

[39]  S. Delp,et al.  Rectus femoris and vastus intermedius fiber excursions predicted by three-dimensional muscle models. , 2006, Journal of biomechanics.

[40]  Scott L. Delp,et al.  Minimally invasive high-speed imaging of sarcomere contractile dynamics in mice and humans , 2008, Nature.

[41]  F. Noyes,et al.  Biomechanics of the knee extension exercise , 1983 .

[42]  R. Brand,et al.  The biomechanics and motor control of human gait: Normal, elderly, and pathological , 1992 .

[43]  P A Huijing,et al.  Effects of distribution of muscle fiber length on active length‐force characteristics of rat gastrocnemius medialis , 1994, The Anatomical record.

[44]  P S Walker,et al.  The effects of knee brace hinge design and placement on joint mechanics. , 1988, Journal of biomechanics.

[45]  Jl Boakes Muscle activity during walking. Human walking , 2006 .

[46]  A. Magid,et al.  Myofibrils bear most of the resting tension in frog skeletal muscle. , 1985, Science.

[47]  S. Delp,et al.  Transfer of the rectus femoris: effects of transfer site on moment arms about the knee and hip. , 1994, Journal of biomechanics.

[48]  W. Herzog,et al.  Force-length relation of in-vivo human rectus femoris muscles , 1988, Pflügers Archiv.

[49]  C. Spoor,et al.  Knee muscle moment arms from MRI and from tendon travel. , 1992, Journal of biomechanics.

[50]  Richard A. Brand,et al.  The biomechanics and motor control of human gait: Normal, elderly, and pathological , 1992 .

[51]  B. Brenner,et al.  A laser diffraction method for measuring muscle sarcomere length in vivo for application to tendon transfers. , 1985, The Journal of hand surgery.

[52]  Ilse Jonkers,et al.  The study of muscle action during single support and swing phase of gait: clinical relevance of forward simulation techniques. , 2003, Gait & posture.

[53]  F.E. Zajac,et al.  An interactive graphics-based model of the lower extremity to study orthopaedic surgical procedures , 1990, IEEE Transactions on Biomedical Engineering.

[54]  G. Lichtwark,et al.  Muscle fascicle and series elastic element length changes along the length of the human gastrocnemius during walking and running. , 2007, Journal of biomechanics.

[55]  R L Lieber,et al.  Sarcomere length operating range of vertebrate muscles during movement. , 2001, The Journal of experimental biology.

[56]  S. Delp,et al.  Accuracy of muscle moment arms estimated from MRI-based musculoskeletal models of the lower extremity. , 2000, Computer aided surgery : official journal of the International Society for Computer Aided Surgery.

[57]  A. McComas,et al.  Influence of joint position on ankle dorsiflexion in humans. , 1981, Journal of applied physiology: respiratory, environmental and exercise physiology.

[58]  G. Ettema Gastrocnemius muscle length in relation to knee and ankle joint angles: Verification of a geometric model and some applications , 1997, The Anatomical record.