Generating standardized image data for testing and calibrating quantification of volumes, surfaces, lengths, and object counts in fibrous and porous materials using X‐ray microtomography

Quantification of the structure and composition of biomaterials using micro‐CT requires image segmentation due to the low contrast and overlapping radioopacity of biological materials. The amount of bias introduced by segmentation procedures is generally unknown. We aim to develop software that generates three‐dimensional models of fibrous and porous structures with known volumes, surfaces, lengths, and object counts in fibrous materials and to provide a software tool that calibrates quantitative micro‐CT assessments. Virtual image stacks were generated using the newly developed software TeIGen, enabling the simulation of micro‐CT scans of unconnected tubes, connected tubes, and porosities. A realistic noise generator was incorporated. Forty image stacks were evaluated using micro‐CT, and the error between the true known and estimated data was quantified. Starting with geometric primitives, the error of the numerical estimation of surfaces and volumes was eliminated, thereby enabling the quantification of volumes and surfaces of colliding objects. Analysis of the sensitivity of the thresholding upon parameters of generated testing image sets revealed the effects of decreasing resolution and increasing noise on the accuracy of the micro‐CT quantification. The size of the error increased with decreasing resolution when the voxel size exceeded 1/10 of the typical object size, which simulated the effect of the smallest details that could still be reliably quantified. Open‐source software for calibrating quantitative micro‐CT assessments by producing and saving virtually generated image data sets with known morphometric data was made freely available to researchers involved in morphometry of three‐dimensional fibrillar and porous structures in micro‐CT scans.

[1]  R. Huiskes,et al.  The influence of microcomputed tomography threshold variations on the assessment of structural and mechanical trabecular bone properties. , 2002, Bone.

[2]  Sim Heng Ong,et al.  Fast segmentation of bone in CT images using 3D adaptive thresholding , 2010, Comput. Biol. Medicine.

[3]  Petra Kochová,et al.  How to asses, visualize and compare the anisotropy of linear structures reconstructed from optical sections--a study based on histopathological quantification of human brain microvessels. , 2011, Journal of theoretical biology.

[4]  D. Kaplan,et al.  Porosity of 3D biomaterial scaffolds and osteogenesis. , 2005, Biomaterials.

[5]  M. Viceconti,et al.  A comparison between micro‐CT and histology for the evaluation of cortical bone: effect of polymethylmethacrylate embedding on structural parameters , 2012, Journal of microscopy.

[6]  P. Kochová,et al.  Collagen/hydroxyapatite scaffold enriched with polycaprolactone nanofibers, thrombocyte-rich solution and mesenchymal stem cells promotes regeneration in large bone defect in vivo. , 2015, Journal of biomedical materials research. Part A.

[7]  J. Schrooten,et al.  The effect of spatial micro-CT image resolution and surface complexity on the morphological 3D analysis of open porous structures , 2014 .

[8]  Stuart R. Stock,et al.  MicroComputed Tomography: Methodology and Applications , 2008 .

[9]  C. Appoloni,et al.  Polymerization shrinkage and porosity profile of dual cure dental resin cements with different adhesion to dentin mechanisms , 2018, Microscopy research and technique.

[10]  E LorensenWilliam,et al.  Marching cubes: A high resolution 3D surface construction algorithm , 1987 .

[11]  William E. Lorensen,et al.  Marching cubes: A high resolution 3D surface construction algorithm , 1987, SIGGRAPH.

[12]  Z. Tonar,et al.  Abdominal closure reinforcement by using polypropylene mesh functionalized with poly-ε-caprolactone nanofibers and growth factors for prevention of incisional hernia formation , 2014, International journal of nanomedicine.

[13]  Reinhard Hickel,et al.  Value and limits of μ‐CT for nondemineralized bone tissue processing , 2012, Microscopy research and technique.

[14]  Omid Majdani,et al.  Three-dimensional histological specimen preparation for accurate imaging and spatial reconstruction of the middle and inner ear , 2013, International Journal of Computer Assisted Radiology and Surgery.

[15]  WilhelmsJane,et al.  Collision Detection and Response for Computer Animation , 1988 .

[16]  Joseph Ross Mitchell,et al.  An algorithm for noise correction of dual-energy computed tomography material density images , 2014, International Journal of Computer Assisted Radiology and Surgery.

[17]  William J. Schroeder,et al.  Visualizing with VTK: A Tutorial , 2000, IEEE Computer Graphics and Applications.

[18]  Peter R. Mouton,et al.  Principles and Practices of Unbiased Stereology: An Introduction for Bioscientists , 2002 .

[19]  Joaquim Teixeira de Assis,et al.  Tridimensional quantitative porosity characterization of three set calcium silicate‐based repair cements for endodontic use , 2013, Microscopy research and technique.

[20]  Dietmar W Hutmacher,et al.  Assessment of bone ingrowth into porous biomaterials using MICRO-CT. , 2007, Biomaterials.

[21]  V. Jenčová,et al.  Comprehensive assessment of electrospun scaffolds hemocompatibility. , 2018, Materials science & engineering. C, Materials for biological applications.

[22]  Kevin W Eliceiri,et al.  NIH Image to ImageJ: 25 years of image analysis , 2012, Nature Methods.

[23]  Lawrence O. Hall,et al.  Unbiased estimation of cell number using the automatic optical fractionator , 2017, Journal of Chemical Neuroanatomy.

[24]  Joaquim Teixeira de Assis,et al.  Stress and strain distribution in demineralized enamel: A micro‐CT based finite element study , 2015, Microscopy research and technique.

[25]  E. Teo,et al.  THE EFFECT OF THRESHOLD VALUE ON THE ARCHITECTURAL PARAMETERS AND STIFFNESS OF HUMAN CANCELLOUS BONE IN MICRO CT ANALYSIS , 2012 .

[26]  Adrian Baddeley,et al.  Stereology for Statisticians , 2004 .

[27]  P. Rüegsegger,et al.  A new method for the model‐independent assessment of thickness in three‐dimensional images , 1997 .

[28]  Steven K Boyd,et al.  Automatic segmentation of cortical and trabecular compartments based on a dual threshold technique for in vivo micro-CT bone analysis. , 2007, Bone.

[29]  S. Gómez,et al.  Characterization and three-dimensional reconstruction of synthetic bone model foams. , 2013, Materials science & engineering. C, Materials for biological applications.

[30]  B. F. Logan,et al.  The Fourier reconstruction of a head section , 1974 .

[31]  Jiří Chmelík,et al.  Accurate micro-computed tomography imaging of pore spaces in collagen-based scaffold , 2016, Journal of Materials Science: Materials in Medicine.

[32]  Edouard Thiel,et al.  Medial axis for chamfer distances: computing look-up tables and neighbourhoods in 2D or 3D , 2002, Pattern Recognit. Lett..

[33]  Dietmar W Hutmacher,et al.  A comparison of micro CT with other techniques used in the characterization of scaffolds. , 2006, Biomaterials.

[34]  Marion Kee,et al.  Analysis , 2004, Machine Translation.

[35]  L. Vojtová,et al.  Calcium Phosphate Foams: Potential Scaffolds for Bone Tissue Modeling in Three Dimensions. , 2017, Methods in molecular biology.

[36]  M. D. Vlad,et al.  Design and properties of 3D scaffolds for bone tissue engineering. , 2016, Acta biomaterialia.

[37]  K Schladitz,et al.  Quantitative micro‐CT , 2011, Journal of microscopy.

[38]  M. Kalbáčová,et al.  The effects of different cross-linking conditions on collagen-based nanocomposite scaffolds—an in vitro evaluation using mesenchymal stem cells , 2015, Biomedical materials.

[39]  Jane Wilhelms,et al.  Collision Detection and Response for Computer Animation , 1988, SIGGRAPH.

[40]  Sharmila Majumdar,et al.  A Local Adaptive Threshold Strategy for High Resolution Peripheral Quantitative Computed Tomography of Trabecular Bone , 2007, Annals of Biomedical Engineering.

[41]  William E. Lorensen,et al.  The visualization toolkit (2nd ed.): an object-oriented approach to 3D graphics , 1998 .

[42]  J. C. Elliott,et al.  X‐ray microtomography , 1982, Journal of microscopy.

[43]  N. Otsu A threshold selection method from gray level histograms , 1979 .

[44]  Douglas G. Altman,et al.  Measurement in Medicine: The Analysis of Method Comparison Studies , 1983 .

[45]  Carme Torras,et al.  3D collision detection: a survey , 2001, Comput. Graph..

[46]  T. Mattfeldt Stochastic Geometry and Its Applications , 1996 .

[47]  Petra Kochová,et al.  Quantification of compact bone microporosities in the basal and alveolar portions of the human mandible using osteocyte lacunar density and area fraction of vascular canals. , 2011, Annals of anatomy = Anatomischer Anzeiger : official organ of the Anatomische Gesellschaft.

[48]  Petra Kochová,et al.  Stereological quantification of microvessels using semiautomated evaluation of X-ray microtomography of hepatic vascular corrosion casts , 2016, International Journal of Computer Assisted Radiology and Surgery.

[49]  C. Lim,et al.  Fabrication of large pores in electrospun nanofibrous scaffolds for cellular infiltration: a review. , 2012, Tissue engineering. Part B, Reviews.

[50]  I. H. Parkinson,et al.  Variation in segmentation of bone from micro-CT imaging: implications for quantitative morphometric analysis , 2008, Australasian Physics & Engineering Sciences in Medicine.

[51]  Steven Nutt,et al.  Direct observation and measurement of fiber architecture in short fiber-polymer composite foam through micro-CT imaging , 2004 .

[52]  Holger Zernetsch,et al.  Electrospun cellular microenvironments: Understanding controlled release and scaffold structure. , 2011, Advanced drug delivery reviews.