Mobile selected ion flow tube mass spectrometry (SIFT-MS) devices and their use for pollution exposure monitoring in breath and ambient air–pilot study

Studies of health effects of air pollution exposure are limited by inability to accurately determine dose and exposure of air pollution in field trials. We explored the feasibility of using a mobile selected ion flow tube mass spectrometry (SIFT-MS) device, housed in a van, to determine ambient air and breath levels of benzene, xylene and toluene following exercise in areas of high motor vehicle traffic. The breath toluene, xylene and benzene concentration of healthy subjects were measured before and after exercising close to a busy road. The concentration of the volatile organic compounds (VOCs), in ambient air were also analysed in real time. Exercise close to traffic pollution is associated with a two-fold increase in breath VOCs (benzene, xylene and toluene) with levels returning to baseline within 20 min. This effect is not seen when exercising away from traffic pollution sources. Situating the testing device 50 m from the road reduced any confounding due to VOCs in the inspired air prior to the breath testing manoeuvre itself. Real-time field testing for air pollution exposure is possible using a mobile SIFT-MS device. This device is suitable for exploring exposure and dose relationships in a number of large scale field test scenarios.

[1]  D. B. Milligan,et al.  Real-time monitoring of hazardous air pollutants. , 2009, Analytical chemistry.

[2]  M. McEwan,et al.  Rapid monitoring of volatile organic compounds: a comparison between gas chromatography/mass spectrometry and selected ion flow tube mass spectrometry. , 2014, Rapid communications in mass spectrometry : RCM.

[3]  D. B. Milligan,et al.  In situ analysis of solvents on breath and blood: a selected ion flow tube mass spectrometric study. , 2002, Rapid communications in mass spectrometry : RCM.

[4]  T. Risby,et al.  Current status of clinical breath analysis , 2005 .

[5]  Simon Kingham,et al.  Determination of personal exposure to traffic pollution while travelling by different modes , 2011 .

[6]  D. B. Milligan,et al.  Application of selected ion flow tube mass spectrometry to real-time atmospheric monitoring. , 2010, Rapid communications in mass spectrometry : RCM.

[7]  Malina K. Storer,et al.  Increased concentrations of breath haloamines are not detectable in airways inflammation using SIFT-MS , 2011, Journal of breath research.

[8]  M. Nieuwenhuijsen,et al.  New developments in exposure assessment: the impact on the practice of health risk assessment and epidemiological studies. , 2006, Environment international.

[9]  G. Teschl,et al.  Isoprene and acetone concentration profiles during exercise on an ergometer , 2009, Journal of breath research.

[10]  Naresh Kumar Uncertainty in the Relationship between Criteria Pollutants and Low Birth Weight in Chicago. , 2012, Atmospheric environment.

[11]  Simon Kingham,et al.  Intraurban variations of PM10 air pollution in Christchurch, New Zealand: implications for epidemiological studies. , 2006, The Science of the total environment.

[12]  T. H. Risby CURRENT STATUS OF CLINICAL BREATH ANALYSIS , 2005 .