MR∕PET quantification tools: registration, segmentation, classification, and MR-based attenuation correction.

PURPOSE Combined MR∕PET is a relatively new, hybrid imaging modality. A human MR∕PET prototype system consisting of a Siemens 3T Trio MR and brain PET insert was installed and tested at our institution. Its present design does not offer measured attenuation correction (AC) using traditional transmission imaging. This study is the development of quantification tools including MR-based AC for quantification in combined MR∕PET for brain imaging. METHODS The developed quantification tools include image registration, segmentation, classification, and MR-based AC. These components were integrated into a single scheme for processing MR∕PET data. The segmentation method is multiscale and based on the Radon transform of brain MR images. It was developed to segment the skull on T1-weighted MR images. A modified fuzzy C-means classification scheme was developed to classify brain tissue into gray matter, white matter, and cerebrospinal fluid. Classified tissue is assigned an attenuation coefficient so that AC factors can be generated. PET emission data are then reconstructed using a three-dimensional ordered sets expectation maximization method with the MR-based AC map. Ten subjects had separate MR and PET scans. The PET with [(11)C]PIB was acquired using a high-resolution research tomography (HRRT) PET. MR-based AC was compared with transmission (TX)-based AC on the HRRT. Seventeen volumes of interest were drawn manually on each subject image to compare the PET activities between the MR-based and TX-based AC methods. RESULTS For skull segmentation, the overlap ratio between our segmented results and the ground truth is 85.2 ± 2.6%. Attenuation correction results from the ten subjects show that the difference between the MR and TX-based methods was <6.5%. CONCLUSIONS MR-based AC compared favorably with conventional transmission-based AC. Quantitative tools including registration, segmentation, classification, and MR-based AC have been developed for use in combined MR∕PET.

[1]  Axel Martinez-Möller,et al.  Evaluation of the attenuation properties of MR equipment for its use in a whole-body PET/MR scanner , 2010, Physics in medicine and biology.

[2]  David L. Wilson,et al.  Image Registration for Interventional MRI Guided Procedures: Interpolation Methods, Similarity Measurements, and Applications to the Prostate , 2003, WBIR.

[3]  Raymond F. Muzic,et al.  Registration of micro-PET and high-resolution MR images of mice for monitoring photodynamic therapy , 2004, SPIE Medical Imaging.

[4]  Gudrun Wagenknecht,et al.  Knowledge-based segmentation of attenuation-relevant regions of the head in T1-weighted MR images for attenuation correction in MR/PET systems , 2009, 2009 IEEE Nuclear Science Symposium Conference Record (NSS/MIC).

[5]  Jun Zhang,et al.  Three-region MRI-based whole-body attenuation correction for automated PET reconstruction. , 2010, Nuclear medicine and biology.

[6]  Habib Zaidi,et al.  Advances in Attenuation Correction Techniques in PET. , 2007, PET clinics.

[7]  Baowei Fei,et al.  A skull segmentation method for brain MR images based on multiscale bilateral filtering scheme , 2010, Medical Imaging.

[8]  Szymon Rusinkiewicz,et al.  Multiscale shape and detail enhancement from multi-light image collections , 2007, ACM Trans. Graph..

[9]  H H Quick,et al.  The effect of MR surface coils on PET quantification in whole-body PET/MR: results from a pseudo-PET/MR phantom study. , 2011, Medical physics.

[10]  John F. Canny,et al.  A Computational Approach to Edge Detection , 1986, IEEE Transactions on Pattern Analysis and Machine Intelligence.

[11]  S. Vandenberghe,et al.  MRI-Based Attenuation Correction for PET/MRI Using Ultrashort Echo Time Sequences , 2010, Journal of Nuclear Medicine.

[12]  Baowei Fei,et al.  MRI-based attenuation correction and quantification tools for combined MRI/PET , 2010 .

[13]  Ilja Bezrukov,et al.  MRI-Based Attenuation Correction for Whole-Body PET/MRI: Quantitative Evaluation of Segmentation- and Atlas-Based Methods , 2011, The Journal of Nuclear Medicine.

[14]  James C. Gee,et al.  Biomedical Image Registration , 2003, Lecture Notes in Computer Science.

[15]  Meritxell Bach Cuadra,et al.  Comparison and validation of tissue modelization and statistical classification methods in T1-weighted MR brain images , 2005, IEEE Transactions on Medical Imaging.

[16]  Christoph Palm,et al.  MR-based attenuation correction for torso-PET/MR imaging: pitfalls in mapping MR to CT data , 2008, European Journal of Nuclear Medicine and Molecular Imaging.

[17]  Xiang Chen,et al.  Automatic intensity-based 3D-to-2D registration of CT volume and dual-energy digital radiography for the detection of cardiac calcification , 2007, SPIE Medical Imaging.

[18]  Ciprian Catana,et al.  Toward Implementing an MRI-Based PET Attenuation-Correction Method for Neurologic Studies on the MR-PET Brain Prototype , 2010, The Journal of Nuclear Medicine.

[19]  Xiaofeng Yang,et al.  An MRI-based attenuation correction method for combined PET/MRI applications , 2009, Medical Imaging.

[20]  V. Schulz,et al.  MR-based attenuation correction for a whole-body sequential PET/MR system , 2009, 2009 IEEE Nuclear Science Symposium Conference Record (NSS/MIC).

[21]  David L. Wilson,et al.  Deformable and rigid registration of MRI and microPET images for photodynamic therapy of cancer in mice. , 2006, Medical physics.

[22]  Xiaofeng Yang,et al.  A multiscale and multiblock fuzzy C-means classification method for brain MR images. , 2011, Medical physics.

[23]  Roberto Manduchi,et al.  Bilateral filtering for gray and color images , 1998, Sixth International Conference on Computer Vision (IEEE Cat. No.98CH36271).

[24]  Gaspar Delso,et al.  The effect of limited MR field of view in MR/PET attenuation correction. , 2010, Medical physics.

[25]  Jiayang Sun,et al.  New technique for real-time interface pressure analysis: getting more out of large image data sets. , 2008, Journal of rehabilitation research and development.

[26]  Alan C. Evans,et al.  MRI Simulation Based Evaluation and Classifications Methods , 1999, IEEE Trans. Medical Imaging.

[27]  A. Evans,et al.  MRI simulation-based evaluation of image-processing and classification methods , 1999, IEEE Transactions on Medical Imaging.

[28]  David L. Wilson,et al.  Semiautomatic nonrigid registration for the prostate and pelvic MR volumes. , 2005, Academic radiology.

[29]  David L Wilson,et al.  Automatic 3D registration for interventional MRI-guided treatment of prostate cancer. , 2002, Computer aided surgery : official journal of the International Society for Computer Aided Surgery.

[30]  Baowei Fei,et al.  Registration and fusion of SPECT, high-resolution MRI, and interventional MRI for thermal ablation of prostate cancer , 2004, IEEE Transactions on Nuclear Science.

[31]  Guy B. Williams,et al.  Attenuation Correction Methods Suitable for Brain Imaging with a PET/MRI Scanner: A Comparison of Tissue Atlas and Template Attenuation Map Approaches , 2011, The Journal of Nuclear Medicine.

[32]  Gerald Q. Maguire,et al.  Comparison and evaluation of retrospective intermodality brain image registration techniques. , 1997, Journal of computer assisted tomography.

[33]  Eduard Schreibmann,et al.  MR-based attenuation correction for hybrid PET-MR brain imaging systems using deformable image registration. , 2010, Medical physics.

[34]  H. Zaidi,et al.  Magnetic resonance imaging-guided attenuation and scatter corrections in three-dimensional brain positron emission tomography. , 2003, Medical physics.

[35]  Ghassan Hamarneh,et al.  Processing, Segmentation, Registration, and Deformation Analysis of 3D MR Images of Mice. , 2003 .

[36]  Debashish Pal,et al.  Attenuation correction for MR table and coils for a sequential PET/MR system , 2009, 2009 IEEE Nuclear Science Symposium Conference Record (NSS/MIC).

[37]  Baowei Fei,et al.  A modified fuzzy C-means classification method using a multiscale diffusion filtering scheme , 2009, Medical Image Anal..

[38]  Bernd J Pichler,et al.  Combined PET/MRI: one step further in multimodality imaging. , 2010, Trends in molecular medicine.

[39]  Nassir Navab,et al.  Tissue Classification as a Potential Approach for Attenuation Correction in Whole-Body PET/MRI: Evaluation with PET/CT Data , 2009, Journal of Nuclear Medicine.

[40]  Jitendra Malik,et al.  Scale-Space and Edge Detection Using Anisotropic Diffusion , 1990, IEEE Trans. Pattern Anal. Mach. Intell..

[41]  H. Herzog,et al.  Alternative methods for attenuation correction for PET images in MR-PET scanners , 2007, 2007 IEEE Nuclear Science Symposium Conference Record.

[42]  R. Günther,et al.  Automatic, three-segment, MR-based attenuation correction for whole-body PET/MR data , 2010, European Journal of Nuclear Medicine and Molecular Imaging.

[43]  Bernhard Schölkopf,et al.  MRI-Based Attenuation Correction for PET/MRI: A Novel Approach Combining Pattern Recognition and Atlas Registration , 2008, Journal of Nuclear Medicine.

[44]  Jonathan S. Lewin,et al.  Image Registration and Fusion for Interventional MRI Guided Thermal Ablation of the Prostate Cancer , 2003, MICCAI.

[45]  David L. Wilson,et al.  Automatic MR volume registration and its evaluation for the pelvis and prostate. , 2002, Physics in medicine and biology.