In vivo anterior tibial post contact after posterior stabilizing total knee arthroplasty

Anterior polyethylene post failure in posterior stabilizing total knee arthroplasty (TKA) has been reported in recent patient follow‐up studies. However, no data have been reported on the biomechanic interaction between the anterior tibial post and femoral component in posterior stabilizing TKA patients under physiological conditions. The objective of this study was to measure the in vivo anterior tibial post contact area at full knee extension using a dual‐orthogonal fluoroscopic imaging technique. Eleven osteoarthritic patients were investigated after posterior stabilizing TKA to measure the contact between the femoral component box and anterior aspect of the tibial post. Anterior tibial post contact, ranging between 0.5 and 80.9 mm2, was detected in 63% of the healthy patients (seven out of the eleven patients) at weight‐bearing full extension of the knee. The patients with anterior tibial post contact had significantly higher hyperextension angles (−8.4 ± 4.3°) than those without contact (1.4 ± 7.2°). A statistically significant difference was also detected in the femoral component flexion with respect to the femoral shaft between the patients with anterior post contact (2.7 ± 2.7°) and without anterior post contact (−1.3 ± 2.2°). These data indicated that anterior post contact did occur in hyperextension within posterior stabilizing TKA patients. While excessive anterior tibial post contact may cause polyethylene wear and potentially lead to post failure, the tibial post may also act as a substitute for the ACL at low flexion, thus providing stability to the joint after posterior stabilizing TKA. © 2007 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 25:1447–1453, 2007

[1]  Mauricio Silva,et al.  Surface Damage on Open Box Posterior-Stabilized Polyethylene Tibial Inserts , 2003, Clinical orthopaedics and related research.

[2]  A Leardini,et al.  Influence of tibial component posterior slope on in vivo knee kinematics in fixed‐bearing total knee arthroplasty , 2006, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[3]  Guoan Li,et al.  Feasibility of using orthogonal fluoroscopic images to measure in vivo joint kinematics. , 2004, Journal of biomechanical engineering.

[4]  Guoan Li,et al.  Investigation of in vivo 6DOF total knee arthoplasty kinematics using a dual orthogonal fluoroscopic system , 2006, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[5]  S A Banks,et al.  In vivo kinematics of cruciate-retaining and -substituting knee arthroplasties. , 1997, The Journal of arthroplasty.

[6]  R B Bourne,et al.  Tibial Post Wear in Posterior Stabilized Total Knee Arthroplasty: An Unrecognized Source of Polyethylene Debris , 2001, The Journal of bone and joint surgery. American volume.

[7]  Tain‐Hsiung Chen,et al.  Fracture of the polyethylene tibial post in a NexGen posterior-stabilized knee prosthesis. , 2004, The Journal of arthroplasty.

[8]  G. Scuderi**,et al.  Polyethylene post failure in posterior stabilized total knee arthroplasty. , 2004, The Journal of arthroplasty.

[9]  D. Hendel,et al.  Fracture of the central polyethylene tibial spine in posterior stabilized total knee arthroplasty. , 2003, The Journal of arthroplasty.

[10]  Mohamed R Mahfouz,et al.  Multicenter Determination of In Vivo Kinematics After Total Knee Arthroplasty , 2003, Clinical orthopaedics and related research.

[11]  T. Johnson,et al.  Anterior tibial post impingement in a posterior stabilized total knee arthroplasty , 2005, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[12]  A H Burstein,et al.  The posterior stabilized condylar prosthesis: a modification of the total condylar design. Two to four-year clinical experience. , 1982, The Journal of bone and joint surgery. American volume.

[13]  Todd Johnson,et al.  Three-dimensional tibiofemoral articular contact kinematics of a cruciate-retaining total knee arthroplasty. , 2006, The Journal of bone and joint surgery. American volume.

[14]  J. D'arcy,et al.  Fracture of the polyethylene tibial post in posterior stabilized (Insall Burstein II) total knee arthroplasty. , 2000, The Journal of arthroplasty.

[15]  P. Campbell,et al.  Tibial Post Impingement in Posterior-Stabilized Total Knee Arthroplasty , 2002, Clinical orthopaedics and related research.

[16]  Guoan Li,et al.  An optimized image matching method for determining in-vivo TKA kinematics with a dual-orthogonal fluoroscopic imaging system. , 2006, Journal of biomechanical engineering.

[17]  H. Rubash,et al.  Determination of in-vivo articular cartilage contact areas of human talocrural joint under weightbearing conditions. , 2006, Osteoarthritis and cartilage.

[18]  Melinda K Harman,et al.  Mechanism of anterior impingement damage in total knee arthroplasty. , 2002, The Journal of bone and joint surgery. American volume.

[19]  O. Mahoney,et al.  Loosening and Osteolysis with the Press-Fit Condylar Posterior-Cruciate-Substituting Total Knee Replacement , 2001, The Journal of bone and joint surgery. American volume.