Illumination-compensated non-contact imaging photoplethysmography via dual-mode temporally coded illumination

Non-contact camera-based imaging photoplethysmography (iPPG) is useful for measuring heart rate in conditions where contact devices are problematic due to issues such as mobility, comfort, and sanitation. Existing iPPG methods analyse the light-tissue interaction of either active or passive (ambient) illumination. Many active iPPG methods assume the incident ambient light is negligible to the active illumination, resulting in high power requirements, while many passive iPPG methods assume near-constant ambient conditions. These assumptions can only be achieved in environments with controlled illumination and thus constrain the use of such devices. To increase the number of possible applications of iPPG devices, we propose a dual-mode active iPPG system that is robust to changes in ambient illumination variations. Our system uses a temporally-coded illumination sequence that is synchronized with the camera to measure both active and ambient illumination interaction for determining heart rate. By subtracting the ambient contribution, the remaining illumination data can be attributed to the controlled illuminant. Our device comprises a camera and an LED illuminant controlled by a microcontroller. The microcontroller drives the temporal code via synchronizing the frame captures and illumination time at the hardware level. By simulating changes in ambient light conditions, experimental results show our device is able to assess heart rate accurately in challenging lighting conditions. By varying the temporal code, we demonstrate the trade-off between camera frame rate and ambient light compensation for optimal blood pulse detection.

[1]  Sijung Hu,et al.  Remote simultaneous dual wavelength imaging photoplethysmography: a further step towards 3-D mapping of skin blood microcirculation , 2008, SPIE BiOS.

[2]  Yu Sun,et al.  Motion-compensated noncontact imaging photoplethysmography to monitor cardiorespiratory status during exercise. , 2011, Journal of biomedical optics.

[3]  Shuchang Xu,et al.  Robust efficient estimation of heart rate pulse from video. , 2014, Biomedical optics express.

[4]  Rosalind W. Picard,et al.  Non-contact, automated cardiac pulse measurements using video imaging and blind source separation , 2022 .

[5]  F. Mastik,et al.  Contactless Multiple Wavelength Photoplethysmographic Imaging: A First Step Toward “SpO2 Camera” Technology , 2005, Annals of Biomedical Engineering.

[6]  B. Li,et al.  Non-contact detection of oxygen saturation based on visible light imaging device using ambient light. , 2013, Optics express.

[7]  T. Ward,et al.  Noncontact simultaneous dual wavelength photoplethysmography: a further step toward noncontact pulse oximetry. , 2007, The Review of scientific instruments.

[8]  Giovanni Cennini,et al.  Heart rate monitoring via remote photoplethysmography with motion artifacts reduction. , 2010, Optics express.

[9]  K. Shelley Photoplethysmography: Beyond the Calculation of Arterial Oxygen Saturation and Heart Rate , 2007, Anesthesia and analgesia.

[10]  Westgate Road,et al.  Photoplethysmography and its application in clinical physiological measurement , 2007 .