A novel gait platform to measure isolated plantar metatarsal forces during walking.

A new gait platform described in this report allows an isolated measurement of the vertical and shear forces under an individual metatarsal head during barefoot walking. The apparatus incorporated a customized tactile force sensor and a high-speed camera system, which enabled easy identification of a single anatomical landmark at the forefoot's plantar surface that is in contact with the sensor throughout stance. After calibration, the measured peak forces under the 2nd MTH showed variability of 3.7%, 9.2%, and 8.9% in vertical, anterior-posterior, and medial-lateral directions, respectively. The device therefore provides information about the magnitude and timing of such local metatarsal forces, and has been shown to be of significant research and clinical interest. Its ability to achieve this with a high degree of accuracy ensures its potential as a valuable research tool.

[1]  B. Davis,et al.  Temporal characteristics of plantar shear distribution: relevance to diabetic patients. , 2008, Journal of biomechanics.

[2]  G. Harris,et al.  A kinetic model of the foot and ankle , 1997 .

[3]  J W Tappin,et al.  Study of the relative timing of shear forces on the sole of the forefoot during walking. , 1991, Journal of biomedical engineering.

[4]  L. Lavery,et al.  Reproducibility of gait analysis variables: one-step versus three-step method of data acquisition. , 2002, The Journal of foot and ankle surgery : official publication of the American College of Foot and Ankle Surgeons.

[5]  V. Macellari,et al.  Pattern of abnormal tangential forces in the diabetic neuropathic foot. , 2001, Clinical biomechanics.

[6]  Bill Vicenzino,et al.  Arch height change during sit-to-stand: an alternative for the navicular drop test , 2008, Journal of foot and ankle research.

[7]  Roy Kj,et al.  Force, pressure, and motion measurements in the foot: current concepts. , 1988, Clinics in podiatric medicine and surgery.

[8]  Brian L Davis,et al.  Simultaneous measurement of plantar pressure and shear forces in diabetic individuals. , 2002, Gait & posture.

[9]  Brian L Davis,et al.  Plantar shear stress distributions: comparing actual and predicted frictional forces at the foot-ground interface. , 2007, Journal of biomechanics.

[10]  J. H. Hicks,et al.  The foot as a support. , 1955, Acta anatomica.

[11]  Brian L. Davis,et al.  A Device for Simultaneous Measurement of Pressure and Shear Force Distribution on the Plantar Surface of the Foot , 1998 .

[12]  B. Davis,et al.  Forefoot plantar shear stress distribution in hallux valgus patients. , 2009, Gait & posture.

[13]  C. Cobelli,et al.  The role of shear stress in the aetiology of diabetic neuropathic foot ulcers , 2008, Journal of Foot and Ankle Research.

[14]  H. Jacob,et al.  Forces acting in the forefoot during normal gait--an estimate. , 2001, Clinical biomechanics.

[15]  Brian L Davis,et al.  Simultaneous shear and pressure sensor array for assessing pressure and shear at foot/ground interface. , 2006, Journal of biomechanics.

[16]  C. Snijders,et al.  Medial Deviation of the First Metatarsal Head as a Result of Flexion Forces in Hallux Valgus , 1992, Foot & ankle.

[17]  P. Cavanagh,et al.  Ulceration, unsteadiness, and uncertainty: the biomechanical consequences of diabetes mellitus. , 1993, Journal of biomechanics.