Proposal for study on IR light and glucose phantom interaction for human glucose quantification applications

It has been established the importance of a constant glucose monitoring in order to keep a regular control for diabetes patients. Several medical studies accept the necessity of exploring alternatives for the traditional digital glucometer, given the pain and discomfort related to this technique, which can lead to a compromised control of the disease. Several efforts based on the application of IR spectroscopy had been done with favorable, yet not conclusive results. Therefore it’s necessary to apply a comprehensive and interdisciplinary study based on the biochemical and optical properties of the glucose in the human body, in order to understand the interaction between this substance, its surroundings and IR light. These study propose a comprehensive approach of the glucose and IR light interaction, considering and combining important biochemical, physiological and optical properties, as well as some machine learning techniques for the data analysis. The results of this work would help to define the right parameters aiming to obtain an optical glucose quantification system and protocol.

[1]  E. Bass,et al.  Comparative Effectiveness and Safety of Methods of Insulin Delivery and Glucose Monitoring for Diabetes Mellitus , 2012, Annals of Internal Medicine.

[3]  J F Lemay,et al.  Blood volumes and pain following capillary punctures in children and adolescents with diabetes. , 1999, Diabetes care.

[4]  Claire F. Gmachl,et al.  In vitro measurements of physiological glucose concentrations in biological fluids using mid-infrared light , 2013, Biomedical optics express.

[5]  Ekaterina A. Sergeeva,et al.  Liquid optical phantoms mimicking spectral characteristics of laboratory mouse biotissues , 2016 .

[6]  Christina Schmid,et al.  System Accuracy Evaluation of 43 Blood Glucose Monitoring Systems for Self-Monitoring of Blood Glucose according to DIN EN ISO 15197 , 2012, Journal of diabetes science and technology.

[7]  J. Lademann,et al.  Two-wavelength carbon dioxide laser application for in-vitro blood glucose measurements. , 2008, Journal of biomedical optics.

[8]  Ling-Sheng Jang,et al.  Glucose detection using an electro-optical fluidic device based on pulse width modulation , 2013, 2013 Seventh International Conference on Sensing Technology (ICST).

[9]  Gabriele Reich,et al.  Near-infrared spectroscopy and imaging: basic principles and pharmaceutical applications. , 2005, Advanced drug delivery reviews.

[10]  S. K. Vashist Non-invasive glucose monitoring technology in diabetes management: a review. , 2012, Analytica chimica acta.

[11]  Marcelo Soto Thompson,et al.  Photodynamic Therapy utilizing Interstitial Light Delivery Combined with Spectroscopic Methods , 2004 .

[12]  Asha Gowda Karegowda,et al.  Cascading K-means Clustering and K-Nearest Neighbor Classifier for Categorization of Diabetic Patients , 2012 .

[13]  A. Davis Medicines By Design. , 2006 .

[14]  Kexin Xu,et al.  Discussion on the validity of NIR spectral data in non-invasive blood glucose sensing , 2013, Biomedical optics express.

[15]  T. R. Jaya Chandra Lekha,et al.  NIR spectroscopic algorithm development for glucose detection , 2015, 2015 International Conference on Innovations in Information, Embedded and Communication Systems (ICIIECS).

[16]  R J McNichols,et al.  Optical glucose sensing in biological fluids: an overview. , 2000, Journal of biomedical optics.

[17]  W. Tamborlane,et al.  A tale of two compartments: interstitial versus blood glucose monitoring. , 2009, Diabetes technology & therapeutics.

[18]  María F. Castilla-Peón,et al.  Knee skin pricking to monitor capillary blood glucose is less painful than finger pricking in children with type 1 diabetes , 2015, International Journal of Diabetes in Developing Countries.

[19]  Markus W. Sigrist,et al.  Glucose sensing in human epidermis using mid-infrared photoacoustic detection , 2012, Biomedical optics express.

[20]  Simon Chak Hing Lam,et al.  Non-invasive blood glucose measurement by near infrared spectroscopy: Machine drift, time drift and physiological effect , 2010 .

[21]  K. S. Rao,et al.  Facile preparation of agarose–chitosan hybrid materials and nanocomposite ionogels using an ionic liquid via dissolution, regeneration and sol–gel transition , 2014, 1409.4962.

[22]  Jessica Doyle,et al.  Noninvasive in vivo glucose sensing on human subjects using mid-infrared light. , 2014, Biomedical optics express.

[23]  M. Burge Lack of compliance with home blood glucose monitoring predicts hospitalization in diabetes. , 2001, Diabetes care.

[24]  C. Lam,et al.  Clinical evaluation of non-invasive blood glucose measurement by using near infrared spectroscopy via inter- and intra-subject analysis , 2009 .

[25]  K. Aagaard,et al.  Twizzlers as a Cost-Effective and Equivalent Alternative to the Glucola Beverage in Diabetes Screening , 2013, Diabetes Care.

[26]  F. Ovalle,et al.  Continuous Glucose Monitoring and Intensive Treatment of Type 1 Diabetes , 2009 .

[27]  Bernhard Lendl,et al.  Application of Mid-Infrared Transmission Spectrometry to the Direct Determination of Glucose in Whole Blood , 1998 .

[28]  D. Klonoff Continuous glucose monitoring: roadmap for 21st century diabetes therapy. , 2005, Diabetes care.