Continuous flow two-dimensional acoustic orientation of nonspherical cells.

Flow cytometry is a frequently used method when it comes to cell sorting and analysis. Nonspherical cells, such as red blood cells or sperm cells, however, pose a challenge as they reduce the precision of light scatter measurements which interfere with the analysis of these and other cell populations in the same sample. Here, we present a microfluidic chip for acoustophoresis utilizing ultrasonic standing waves to focus and orient red blood cells in two dimensions in the channel center. The cells can be oriented to show either their flat or up-ended side toward the optical axis and the observer. In an acoustic standing wave field the cells will be rotated until the direction of the smallest dimension is parallel with the direction where the acoustic energy is strongest. While keeping the cells focused in the channel center utilizing acoustic resonances in two dimensions, the orientation can be controlled by increasing the acoustic energy in either the horizontal or vertical resonance mode. It was shown that 87.8 ± 3.8% of the red blood cells could be horizontally oriented while 98.7 ± 0.3% could be vertically oriented. The ability to control the orientation of nonspherical cells with high accuracy is a beneficial feature and potential contribution to the rapidly growing field of flow and image cytometry.

[1]  Carl Grenvall,et al.  Acoustic actuated fluorescence activated sorting of microparticles. , 2014, Lab on a chip.

[2]  Thomas Laurell,et al.  Microchannel Acoustophoresis does not Impact Survival or Function of Microglia, Leukocytes or Tumor Cells , 2013, PloS one.

[3]  Wenfeng Liang,et al.  Self-Rotation of Cells in an Irrotational AC E-Field in an Opto-Electrokinetics Chip , 2013, PloS one.

[4]  Carl Grenvall,et al.  Label‐free somatic cell cytometry in raw milk using acoustophoresis , 2012, Cytometry. Part A : the journal of the International Society for Analytical Cytology.

[5]  T. Laurell,et al.  Two-hundredfold volume concentration of dilute cell and particle suspensions using chip integrated multistage acoustophoresis. , 2012, Lab on a chip.

[6]  H. Lilja,et al.  Microfluidic, label-free enrichment of prostate cancer cells in blood based on acoustophoresis. , 2012, Analytical chemistry.

[7]  Wei Wang,et al.  Autonomous motion of metallic microrods propelled by ultrasound. , 2012, ACS nano.

[8]  Martin Wiklund,et al.  Acoustofluidics 12: Biocompatibility and Cell Viability in Microfluidic Acoustic Resonators I Introduction Lab on a Chip , 2022 .

[9]  Menake E Piyasena,et al.  Multinode acoustic focusing for parallel flow cytometry. , 2012, Analytical chemistry.

[10]  Jason P Beech,et al.  Sorting cells by size, shape and deformability. , 2012, Lab on a chip.

[11]  Risto Myllylä,et al.  Effect of the size and shape of a red blood cell on elastic light scattering properties at the single-cell level , 2011, Biomedical optics express.

[12]  K. M. Evans,et al.  Advances in flow cytometry for sperm sexing. , 2009, Theriogenology.

[13]  Thomas Laurell,et al.  Acoustophoresis in wet-etched glass chips. , 2008, Analytical chemistry.

[14]  R. Tompkins,et al.  Continuous inertial focusing, ordering, and separation of particles in microchannels , 2007, Proceedings of the National Academy of Sciences.

[15]  Khyati Mohanty,et al.  Orientation of erythrocytes in optical trap revealed by confocal fluorescence microscopy. , 2007, Journal of biomedical optics.

[16]  Thomas Laurell,et al.  Chip integrated strategies for acoustic separation and manipulation of cells and particles. , 2007, Chemical Society reviews.

[17]  Steven W Graves,et al.  Ultrasonic particle‐concentration for sheathless focusing of particles for analysis in a flow cytometer , 2006, Cytometry. Part A : the journal of the International Society for Analytical Cytology.

[18]  T. Takeuchi,et al.  Orientation of bull sperms in static magnetic fields. , 2001, Bioelectromagnetics.

[19]  M L Mendelsohn,et al.  Hydrodynamic orientation of sperm heads for flow cytometry. , 1978, Biophysical journal.