Determination of polychlorinated biphenyls and organochlorine pesticides in human serum by gas chromatography with micro-electron capture detector.

A method for determination of concentrations of polychlorinated biphenyl congeners (PCB-28, 52, 101, 118, 138, 153, 156, and 187) and organochlorine pesticides (hexachlorobenzene, alpha-hexachlorocyclohexane, beta-hexachlorocyclohexane, gamma-hexachlorocyclohexane, delta-hexachlorocyclohexane, p,p'-dichlorodiphenyl dichloroethylene, o,p'-dichlorodiphenyl trichloroethane, p,p'-dichlorodiphenyl dichloroethane, p,p'-dichlorodiphenyl trichloroethane, alpha-chlordane, gamma-chlordane, heptachlor, heptachlor epoxide, and aldrin) in human serum is developed. Recovery is assessed with artificial serum, in which PCBs and OCPs could not be detected. The method is then confirmed with pooled human serum. Experiments are performed by adding two concentrations of analytes (0.5 µg/L and 1.0 µg/L) to both matrices. The sample pretreatment process involves denaturing with a mixture of water-1-propanol (v:v, 85:15), extraction with a C-18 cartridge, and cleanup with an Alumina B cartridge. This process required about 2 mL of serum. The limit of detection ranged from 0.05-0.35 µg/L for all the analytes. Recovery of analytes at low and high spiking concentrations varied from 63-122% and 61-124% for artificial serum and pooled human serum, respectively. Relative standard deviation was lower than 16% and 18% for artificial serum and pooled human serum, respectively. Stability of the method, expressed as relative standard deviation, was lower than 14%. The method has been applied in epidemiological research.

[1]  Lyn Denison,et al.  Stockholm Convention on Persistent Organic Pollutants , 2013 .

[2]  M. El-Shahawi,et al.  An overview on the accumulation, distribution, transformations, toxicity and analytical methods for the monitoring of persistent organic pollutants. , 2010, Talanta.

[3]  Buu N. Tran,et al.  Analysis of polychlorinated biphenyls in human serum by gas chromatography-mass selective detection operating at high ion source temperature. , 2009, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[4]  Yoon-Seok Chang,et al.  Distribution of organochlorine pesticides (OCPs) and polychlorinated biphenyls (PCBs) in human serum from urban areas in Korea. , 2008, Chemosphere.

[5]  John J. Evans,et al.  Quantification of low levels of organochlorine pesticides using small volumes (, 2007, Environmental pollution.

[6]  B. Gómara,et al.  A simple and fast method for the simultaneous determination of polychlorinated biphenyls and polybrominated diphenyl ethers in small volumes of human serum. , 2007, Journal of chromatography. A.

[7]  P. Amiano,et al.  High throughput method for the determination of organochlorine pesticides and polychlorinated biphenyls in human serum. , 2007, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[8]  Wen Li,et al.  Prenatal exposures to persistent organic pollutants as measured in cord blood and meconium from three localities of Zhejiang, China. , 2007, The Science of the total environment.

[9]  X. Shu,et al.  Association of serum concentration of organochlorine pesticides with dietary intake and other lifestyle factors among urban Chinese women. , 2007, Environment international.

[10]  John J. Evans,et al.  A simple and fast extraction method for organochlorine pesticides and polychlorinated biphenyls in small volumes of avian serum. , 2006, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[11]  A. Kočan,et al.  Simple solid-phase extraction method for determination of polychlorinated biphenyls and selected organochlorine pesticides in human serum. , 2005, Journal of chromatography. A.

[12]  P. Langer,et al.  Human thyroid in the population exposed to high environmental pollution by organochlorinated pollutants for several decades. , 2005, Endocrine regulations.

[13]  Dana B Barr,et al.  Analytical methods for biological monitoring of exposure to pesticides: a review. , 2002, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[14]  Siu C Chan,et al.  Analysis of pesticides and PCB congeners in serum by GC/MS with SPE sample cleanup. , 2002, Toxicology letters.

[15]  Cristina Aprea,et al.  Biological monitoring of pesticide exposure: a review of analytical methods. , 2002, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[16]  G. Winneke,et al.  Determination of polychlorinated biphenyls and chlorinated pesticides in human body fluids and tissues. , 1996, Journal of chromatography. A.

[17]  C. C. Hodge,et al.  An improved analysis for chlorinated pesticides and polychlorinated biphenyls (PCBs) in human and bovine sera using solid-phase extraction. , 1996, Journal of analytical toxicology.

[18]  M. L. Ribeiro,et al.  Quantitative method for the determination of organochlorine pesticides in serum. , 1996, Journal of analytical toxicology.

[19]  U. Gill,et al.  Congener specific analysis of polychlorinated biphenyls (PCBs) in serum using GC/MSD. , 1995, Chemosphere.