Mechanisms of Wave Fractionation at Boundaries of High-Frequency Excitation in the Posterior Left Atrium of the Isolated Sheep Heart During Atrial Fibrillation

Background— High-frequency fractionated electrograms recorded during atrial fibrillation (AF) in the posterior left atrium (PLA) and elsewhere are being used as target sites for catheter ablation. We tested the hypothesis that highly periodic electric waves emerging from AF sources at or near the PLA give rise to the most fractionated activity in adjacent locations. Methods and Results— Sustained AF was induced in 8 isolated sheep hearts (0.5 &mgr;mol/L acetylcholine). Endocardial videoimaging (DI-4-ANEPPS) and electric mapping of the PLA enabled spatial characterization of dominant frequencies (DFs) and a regularity index (ratio of DF to total power). Regularity index showed that fractionation was lowest within the area with the maximal DF (DFmax domain; 0.19±0.02) and highest within a band of ≈3 mm (0.16±0.02; P=0.047) at boundaries with lower-frequency domains. The numbers of spatiotemporal periodic episodes (25.9±2.3) and rotors per experiment (1.9±0.7) were also highest within the DFmax domain. Most commonly, breakthrough waves at the PLA traveled toward the rest of the atria (76.8±8.1% outward versus 23.2±8.1% inward; P<0.01). In both experiments and simulations with an atrial ionic model, fractionation at DFmax boundaries was associated with increased beat-to-beat variability of conduction velocity and directionality with wavebreak formation. Conclusions— During stable AF, the PLA harbors regular, fast, and highly organized activity; the outer limit of the DFmax domain is the area where the most propagation pattern variability and fractionated activity occur. These new concepts introduce a new perspective in the clinical use of high-frequency fractionated electrograms to localize sources of AF precisely at the PLA and elsewhere.

[1]  O. Alfieri,et al.  Atrial Electroanatomic Remodeling After Circumferential Radiofrequency Pulmonary Vein Ablation: Efficacy of an Anatomic Approach in a Large Cohort of Patients With Atrial Fibrillation , 2001, Circulation.

[2]  G. Guiraudon,et al.  Catheter and surgical ablation strategies in atrial fibrillation: what have we learned? , 2005, Current opinion in cardiology.

[3]  J. Jalife,et al.  Cardiac Electrophysiology: From Cell to Bedside , 1990 .

[4]  Sander Verheule,et al.  Arrhythmogenic Substrate of the Pulmonary Veins Assessed by High-Resolution Optical Mapping , 2003, Circulation.

[5]  Hakan Oral,et al.  Pulmonary Vein Isolation for Paroxysmal and Persistent Atrial Fibrillation , 2002, Circulation.

[6]  M. Mansour,et al.  Spatially Distributed Dominant Excitation Frequencies Reveal Hidden Organization in Atrial Fibrillation in the Langendorff‐Perfused Sheep Heart , 2000, Journal of cardiovascular electrophysiology.

[7]  José Jalife,et al.  Cholinergic atrial fibrillation: I(K,ACh) gradients determine unequal left/right atrial frequencies and rotor dynamics. , 2003, Cardiovascular research.

[8]  Prashanthan Sanders,et al.  Spectral Analysis Identifies Sites of High-Frequency Activity Maintaining Atrial Fibrillation in Humans , 2005, Circulation.

[9]  OmerBerenfeld,et al.  Spectral Analysis Identifies Sites of High-Frequency Activity Maintaining Atrial Fibrillation in Humans , 2005 .

[10]  Eberhard Bodenschatz,et al.  Spatiotemporal Transition to Conduction Block in Canine Ventricle , 2002, Circulation research.

[11]  F. Morady,et al.  Segmental Ostial Ablation to Isolate the Pulmonary Veins During Atrial Fibrillation: Feasibility and Mechanistic Insights , 2002, Circulation.

[12]  Shien-Fong Lin,et al.  Intracellular Calcium Dynamics and Anisotropic Reentry in Isolated Canine Pulmonary Veins and Left Atrium , 2005, Circulation.

[13]  J Jalife,et al.  Stable microreentrant sources as a mechanism of atrial fibrillation in the isolated sheep heart. , 2000, Circulation.

[14]  José Jalife,et al.  Frequency-Dependent Breakdown of Wave Propagation Into Fibrillatory Conduction Across the Pectinate Muscle Network in the Isolated Sheep Right Atrium , 2002, Circulation research.

[15]  L. J. Leon,et al.  Cholinergic Atrial Fibrillation in a Computer Model of a Two-Dimensional Sheet of Canine Atrial Cells With Realistic Ionic Properties , 2002, Circulation research.

[16]  J Jalife,et al.  Distribution of excitation frequencies on the epicardial and endocardial surfaces of fibrillating ventricular wall of the sheep heart. , 2000, Circulation research.

[17]  S. Nattel,et al.  Intra-Atrial Pressure Increases Rate and Organization of Waves Emanating From the Superior Pulmonary Veins During Atrial Fibrillation , 2003, Circulation.

[18]  J Jalife,et al.  Rectification of the Background Potassium Current: A Determinant of Rotor Dynamics in Ventricular Fibrillation , 2001, Circulation research.

[19]  J Clémenty,et al.  Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins. , 1998, The New England journal of medicine.

[20]  G. Guiraudon,et al.  Role of the Posterior Left Atrium and Pulmonary Veins in Human Lone Atrial Fibrillation: Electrophysiological and Pathological Data From Patients Undergoing Atrial Fibrillation Surgery , 2003, Circulation.

[21]  H. Nathan,et al.  Myocardial atrio-venous junctions and extensions (sleeves) over the pulmonary and caval veins , 1970, Thorax.

[22]  A. Skanes,et al.  Spatiotemporal periodicity during atrial fibrillation in the isolated sheep heart. , 1998, Circulation.

[23]  Mark Potse,et al.  Electrical Conduction in Canine Pulmonary Veins: Electrophysiological and Anatomic Correlation , 2002, Circulation.

[24]  K. Nademanee,et al.  A new approach for catheter ablation of atrial fibrillation: mapping of the electrophysiologic substrate. , 2004, Journal of the American College of Cardiology.

[25]  J Clémenty,et al.  A focal source of atrial fibrillation treated by discrete radiofrequency ablation. , 1997, Circulation.

[26]  M. Mansour,et al.  Left-to-Right Gradient of Atrial Frequencies During Acute Atrial Fibrillation in the Isolated Sheep Heart , 2001, Circulation.