Assessment of Correlation between Electrogoniometer Measurements and Sports-Specific Movement in Karate Elites

Purpose To examine the intra-rater reliability of knee movement data in sagital plane obtained from electrogoniometer (EGM) in a basic, sport-specific task of karate. Methods A total of 23 elite karate athletes (13 females and 10 males; mean age of 16.10±1.26 yrs) participated in this study. The task was defined as performing three consecutive Zenkutsu-dachi in two sessions. The used EGM was a twin axis of Biometrics company. EGM curves were plotted in MATLAB software separately. The indices of three points in the plots corresponding to extremes of flexion and extension of knee in the first dachi were determined. There was also another (forth) point which was not in extremes of movement. As it was repeated in all curves, it was perceived as a biomechanical event and was assessed. The phases of movement between the points were scaled between 0 to 100% of activity. Results Repeatability of the forth point index was assessed by intraclass correlation method. Intraclass correlation of the ratio in the first testing session was 0.666 and in second was 0.448. The interval between points were considered as phases of movement. After determining three phases of dachi, it was shown that these phases pertained a specific ratio of the total plot which were 48%, 36% and 16% of total respectively. Conclusion Dachi could be divided into three distinct phases; each of them should constitute a specific percent of the total in an elite athlete.

[1]  C. Myles,et al.  Movement of the knee in osteoarthritis. The use of electrogoniometry to assess function. , 2001, The Journal of bone and joint surgery. British volume.

[2]  J Isacson,et al.  Three-dimensional electrogoniometric gait recording. , 1986, Journal of biomechanics.

[3]  B. Van Gheluwe,et al.  Reliability and accuracy of biomechanical measurements of the lower extremities. , 2002, Journal of the American Podiatric Medical Association.

[4]  Pagamas Piriyaprasarth,et al.  The reliability of knee joint position testing using electrogoniometry , 2008, BMC musculoskeletal disorders.

[5]  Ramin Kordi,et al.  Combat sports medicine , 2009 .

[6]  Philip Rowe,et al.  Validation of Flexible Electrogoniometry as a Measure of Joint Kinematics , 2001 .

[7]  G Atkinson,et al.  Statistical Methods For Assessing Measurement Error (Reliability) in Variables Relevant to Sports Medicine , 1998, Sports medicine.

[8]  P. Faghri,et al.  A Prospective Study of Overuse Knee Injuries Among Female Athletes With Muscle Imbalances and Structural Abnormalities. , 2004, Journal of athletic training.

[9]  R. Marshall,et al.  Reliability of biomechanical variables of sprint running. , 2004, Medicine and science in sports and exercise.

[10]  F. Wood,et al.  Goniometry and linear assessments to monitor movement outcomes: are they reliable tools in burn survivors? , 2009, Burns : journal of the International Society for Burn Injuries.

[11]  H. van Mameren,et al.  Digital goniometric measurement of knee joint motion. Evaluation of usefulness for research settings and clinical practice. , 2007, The Knee.

[12]  R. Oostendorp,et al.  Inter-rater reliability for measurement of passive physiological movements in lower extremity joints is generally low: a systematic review. , 2010, Journal of physiotherapy.

[13]  Mark A Carey,et al.  Reliability, validity, and clinical usability of a digital goniometer. , 2010, Work.

[14]  N. Limpaphayom,et al.  Reliability of digital compass goniometer in knee joint range of motion measurement. , 2009, Journal of the Medical Association of Thailand = Chotmaihet thangphaet.

[15]  J. Weir Quantifying test-retest reliability using the intraclass correlation coefficient and the SEM. , 2005, Journal of strength and conditioning research.

[16]  Emiel van Trijffel,et al.  Inter-rater reliability for measurement of passive physiological range of motion of upper extremity joints is better if instruments are used: a systematic review. , 2010, Journal of physiotherapy.

[17]  Darin A Padua,et al.  Ankle-dorsiflexion range of motion and landing biomechanics. , 2011, Journal of athletic training.

[18]  R. Shapiro,et al.  Hamstring extensibility and transverse plane knee control relationship in athletic women , 1999, Knee Surgery, Sports Traumatology, Arthroscopy.

[19]  J. Hidler,et al.  Biomechanics of overground vs. treadmill walking in healthy individuals. , 2008, Journal of applied physiology.

[20]  Clare E. Milner,et al.  Test-retest reliability of knee biomechanics during stop jump landings. , 2011, Journal of biomechanics.

[21]  S. Bronner,et al.  Reliability and validity of a new ankle electrogoniometer , 2010, Journal of medical engineering & technology.