Modified monolayer electrodes for electrochemical and piezoelectric analysis of substrate-receptor interactions: novel immunosensor electrodes

Abstract Monolayer-modified Au-electrodes were used to analyze electrochemically host-guest binding interactions of biomaterials. Two configurations to sense the binding of an antibody and a lectin to the complementary substrate monolayer are addressed. In one configuration, a fluorescein monolayer was assembled on an Au-electrode and binding of the complementary anti-fluorescein antibody Flc-Ab was followed by the examination of electrode insulation by the antibody towards a solubilized redox probe, Fe(CN) 6 3− /Fe(CN) 6 4− . The extent of electrode insulation is controlled by the Flc-Ab concentration in the sample and the electrode responds amperometrically to Flc-Ab concentrations as low as 0.7 μI. The second configuration applies a redox-modified protein to analyze competitively the protein itself. An Au-electrode was modified by an α- d -mannopyranose monolayer, and a bipyridinium-modified concanavalin A was used to analyze concanavalin A (Con. A). Competitive binding of the redox-modified Con. A and the analyzed Con. A to the monolayer-modified electrode occurred, and the amperometric response was inversely proportional to the Con. A concentration. Quartz crystals coated with Au-electrodes were applied for the piezoelectric QCM analyses of Flc-Ab and Con. A. The crystal electrodes are modified with a fluorescein antigen monolayer. The Flc-Ab was sensed by the changes in the crystal frequencies as a result of the antibody association to the electrode. Flc-Ab at a concentration as low as 5 ng ml −1 was detected. The series of monosaccharides α- d -mannopyranose, β- d -glucose or α- d -glucose was assembled onto the Au-electrodes of the quartz crystals and used as a sensing interface for concanavalin A. The α- d -mannopyranose monolayer revealed high affinity for the binding of Con. A, whereas the β- d -glucose monolayer showed lower affinity for the protein, and the α- d -glucose monolayer lacked association to Con. A. The monolayer-modified quartz crystal electrodes revealed specificity for the respective complementary proteins.

[1]  Michael Grätzel,et al.  Detection of viruses and bacteria with piezoelectric immunosensors , 1993 .

[2]  Eugenii Katz,et al.  A chemically modified electrode capable of a spontaneous immobilization of amino compounds due to its functionalization with succinimidyl groups , 1990 .

[3]  D. S. Hage,et al.  High-performance immunoaffinity chromatography and chemiluminescent detection in the automation of a parathyroid hormone sandwich immunoassay. , 1991, Analytical chemistry.

[4]  George G. Guilbault,et al.  Food biosensor analysis. , 1994 .

[5]  T. Ngo Electrochemical Sensors in Immunological Analysis , 1987, Springer US.

[6]  I. Willner,et al.  Glucose and Acetylcholine Sensing Multilayer Enzyme Electrodes of Controlled Enzyme Layer Thickness , 1995 .

[7]  J. Roederer,et al.  Microgravimetric immunoassay with piezoelectric crystals , 1983 .

[8]  Isao Karube,et al.  Piezoelectric immuno sensor for the detection of candida albicans microbes , 1986 .

[9]  Itamar Willner,et al.  Electron-Transfer Communication in Glutathione Reductase Assemblies: Electrocatalytic, Photocatalytic, and Catalytic Systems for the Reduction of Oxidized Glutathione , 1994 .

[10]  M. Ward,et al.  In Situ Interfacial Mass Detection with Piezoelectric Transducers , 1990, Science.

[11]  W. Heineman,et al.  Electrochemical enzyme immunoassay for phenytoin by flow-injection analysis incorporating a redox coupling agent. , 1991, Clinical chemistry.

[12]  K. A. Davis,et al.  Continuous liquid-phase piezoelectric biosensor for kinetic immunoassays. , 1989, Analytical chemistry.

[13]  E Tamiya,et al.  Piezoelectric crystal biosensor modified with protein A for determination of immunoglobulins. , 1987, Analytical chemistry.

[14]  H. Hill,et al.  Homogeneous amperometric ligand-binding assay amplified by a proteolytic enzyme cascade , 1989 .

[15]  M. Grätzel,et al.  A novel immunosensor for herpes viruses. , 1994, Analytical chemistry.

[16]  G G Guilbault,et al.  Recent developments in piezoelectric immunosensors. A review. , 1994, The Analyst.

[17]  Daniel Thomas,et al.  Oxygen electrode-based enzyme immunoassay for the amperometric determination of hepatitis B surface antigen , 1984 .

[18]  G. S. Wilson,et al.  Rapid sub-picomole electrochemical enzyme immunoassay for immunoglobulin G. , 1985, Analytical chemistry.

[19]  H. Hill,et al.  Homogeneous ferrocene-mediated amperometric immunoassay. , 1986, Analytical chemistry.

[20]  Boris Tartakovsky,et al.  A bilirubin biosensor based on a multilayer network enzyme electrode , 1995 .

[21]  I. Willner,et al.  Photoregulated binding of spiropyran-modified concanavalin A to monosaccharide-functionalized self-assembled monolayers on gold electrodes , 1993 .

[22]  Y. Okahata,et al.  A Kinetic Study of Concanavalin A Binding to Glycolipid Monolayers by Using a Quartz-Crystal Microbalance , 1994 .

[23]  I. Karube,et al.  Piezoelectric Crystal Biosensor System for Detection of Escherichia Coli , 1989 .

[24]  J. Gosling A decade of development in immunoassay methodology. , 1990, Clinical chemistry.

[25]  Itamar Willner,et al.  Development of novel biosensor enzyme electrodes: Glucose oxidase multilayer arrays immobilized onto self‐assembled monolayers on electrodes , 1993 .

[26]  N. Walton,et al.  The development of redox-modified electrodes as charge-accumulating devices for use in higher sensitivity detection systems , 1988 .

[27]  G G Guilbault,et al.  A piezoelectric immunobiosensor for atrazine in drinking water. , 1992, Biosensors & bioelectronics.

[28]  W. Heineman,et al.  Competitive heterogeneous enzyme immunoassay for digoxin with electrochemical detection. , 1986, Analytical chemistry.

[29]  I. Willner,et al.  APPLICATION OF PHOTOISOMERIZABLE ANTIGENIC MONOLAYER ELECTRODES AS REVERSIBLE AMPEROMETRIC IMMUNOSENSORS , 1994 .