Automated live cell screening system based on a 24-well-microplate with integrated micro fluidics

In research, pharmacologic drug-screening and medical diagnostics, the trend towards the utilization of functional assays using living cells is persisting. Research groups working with living cells are confronted with the problem, that common endpoint measurement methods are not able to map dynamic changes. With consideration of time as a further dimension, the dynamic and networked molecular processes of cells in culture can be monitored. These processes can be investigated by measuring several extracellular parameters. This paper describes a high-content system that provides real-time monitoring data of cell parameters (metabolic and morphological alterations), e.g., upon treatment with drug compounds. Accessible are acidification rates, the oxygen consumption and changes in adhesion forces within 24 cell cultures in parallel. Addressing the rising interest in biomedical and pharmacological high-content screening assays, a concept has been developed, which integrates multi-parametric sensor readout, automated imaging and probe handling into a single embedded platform. A life-maintenance system keeps important environmental parameters (gas, humidity, sterility, temperature) constant.

[1]  FRAP, FLIP, FRET, BRET, FLIM, PRIM… : De nouvelles techniques pour voir la vie en couleur ! , 2004 .

[2]  G. Trugnan,et al.  [FRAP, FLIP, FRET, BRET, FLIM, PRIM...new techniques for a colourful life]. , 2004, Medecine sciences : M/S.

[3]  B Wolf,et al.  Functional cellular assays with multiparametric silicon sensor chips. , 2003, Lab on a chip.

[4]  Bernhard Wolf,et al.  Cellular assays with multiparametric bioelectronic sensor chips , 2005 .

[5]  M. Entzeroth,et al.  Emerging trends in high-throughput screening. , 2003, Current opinion in pharmacology.

[6]  K Moore,et al.  Cell-Based Versus Isolated Target Screening: How Lucky Do You Feel? , 2001, Journal of biomolecular screening.

[7]  Bernhard Wolf,et al.  Chip statt Maus: Mikrosensorarrays zur Chemikalienprüfung , 2006 .

[8]  G. J. Brakenhoff,et al.  Confocal scanning light microscopy with high aperture immersion lenses , 1979 .

[9]  N. Thompson,et al.  Total internal inflection fluorescent microscopy. , 1983, Journal of microscopy.

[10]  Ingo Klimant,et al.  Characterization of microtiterplates with integrated optical sensors for oxygen and pH, and their applications to enzyme activity screening, respirometry, and toxicological assays , 2006 .

[11]  Michael Kraus,et al.  Structured Biological Modelling: A New Approach to Biophysical Cell Biology , 1995 .

[12]  Gaudenz Danuser,et al.  FRET or no FRET: a quantitative comparison. , 2003, Biophysical journal.

[13]  Thomas Geisler,et al.  Automated multiparametric platform for high-content and high-Throughput Analytical screening on living cells , 2006, IEEE Transactions on Automation Science and Engineering.

[14]  B Wolf,et al.  Monitoring of cellular behaviour by impedance measurements on interdigitated electrode structures. , 1997, Biosensors & bioelectronics.

[15]  Thomas Weyh,et al.  Living Cells on Chip: Bioanalytical Applications , 2004 .

[16]  Daniel Axelrod,et al.  Total internal reflection fluorescent microscopy , 1983 .

[17]  R. Hertzberg,et al.  High-throughput screening: new technology for the 21st century. , 2000, Current opinion in chemical biology.

[18]  K. Fujita [Two-photon laser scanning fluorescence microscopy]. , 2007, Tanpakushitsu kakusan koso. Protein, nucleic acid, enzyme.