Cardiac activity detection: A fast prototyping approach with health safety considerations

This paper presents a fast prototyping approach for the construction of a Doppler radar system operating at 24-GHz ISM-Band for noncontact detection of cardiac activities. The hardware system consists of an off-the-shelf radar sensor, a signal conditioning board and a Notebook computer. A two-step dc offsets removal technique is exploited to measure the cardiac activities in arctangent demodulation procedure. Various health safety regulations (for subjecting human body to radar signals) have also been studied and the requirements for system design and operating conditions are proposed (to ensure that the system operates within the health safety regulations). Experiments involving stationary human subjects have been carried out. The results obtained show that, the cardiac waveform can be detected clearly and the heart rates can be measured with accuracy higher than 98% when the radar system operates at 0.5 meter away from the human subject.

[1]  G. El Zein,et al.  Low power microwave systems for heartbeat rate detection at 2.4, 5.8, 10 and 16 GHz , 2008, 2008 First International Symposium on Applied Sciences on Biomedical and Communication Technologies.

[2]  James C. Lin,et al.  A new IEEE standard for safety levels with respect to human exposure to radio-frequency radiation , 2006 .

[3]  Byung-Kwon Park,et al.  Arctangent Demodulation With DC Offset Compensation in Quadrature Doppler Radar Receiver Systems , 2007, IEEE Transactions on Microwave Theory and Techniques.

[4]  Changzhi Li,et al.  Complex signal demodulation and random body movement cancellation techniques for non-contact vital sign detection , 2008, IMS 2008.

[5]  Jenshan Lin,et al.  Range correlation and I/Q performance benefits in single-chip silicon Doppler radars for noncontact cardiopulmonary monitoring , 2004, IEEE Transactions on Microwave Theory and Techniques.

[6]  A. Ahlbom Guidelines for limiting exposure to time-varying electric, magnetic, and electromagnetic fields (up to 300 GHz) , 1998 .

[7]  Ieee Standards Board IEEE standard for safety levels with respect to human exposure to radio frequency electromagnetic fields, 3kHz to 300 GHz , 1992 .

[8]  Changzhi Li,et al.  A Portable Noncontact Heartbeat and Respiration Monitoring System Using 5-GHz Radar , 2007, IEEE Sensors Journal.

[9]  James C. Lin,et al.  Microwave Apexcardiography , 1979 .

[10]  Changzhi Li,et al.  Recent advances in Doppler radar sensors for pervasive healthcare monitoring , 2010, 2010 Asia-Pacific Microwave Conference.