Floating navigator echo (FNAV) for in‐plane 2D translational motion estimation

A modification of the classical navigator echo (NAV) technique is presented whereby both 2D translational motion components are computed from a single navigator line. Instead of acquiring the NAV at the center of the k‐space, a kx line is acquired off‐center in the phase‐encoding (ky) direction as a floating NAV (FNAV). It is shown that the translational motion in both the readout and phase‐encoding directions can be computed from this line. The algorithm used is described in detail and verified experimentally. The new technique can be readily implemented to replace classic NAV in MRI sequences, with little to no additional cost or complexity. The new method can help suppress 2D translational motion and provide more accurate motion estimates for other motion‐suppression techniques, such as the diminishing variance algorithm. Magn Reson Med 51:403–407, 2004. © 2004 Wiley‐Liss, Inc.

[1]  David Atkinson,et al.  Automatic correction of motion artifacts in magnetic resonance images using an entropy focus criterion , 1997, IEEE Transactions on Medical Imaging.

[2]  B. Logan,et al.  Reconstructing Interior Head Tissue from X-Ray Transmissions , 1974 .

[3]  H. Gudbjartsson,et al.  The rician distribution of noisy mri data , 1995, Magnetic resonance in medicine.

[4]  J. Felmlee,et al.  Adaptive technique for high-definition MR imaging of moving structures. , 1989, Radiology.

[5]  Ronald N. Bracewell,et al.  The Fourier Transform and Its Applications , 1966 .

[6]  Li Tang,et al.  An improved method for MRI artifact correction due to translational motion in the imaging plane , 1995, IEEE Trans. Medical Imaging.

[7]  Mark Hedley,et al.  A modified Gerchberg-Saxton algorithm for one-dimensional motion artifact correction in MRI , 1991, IEEE Trans. Signal Process..

[8]  Clifford R. Jack,et al.  Spherical navigator echoes for full 3D rigid body motion measurement in MRI , 2001, SPIE Medical Imaging.

[9]  J. Felmlee,et al.  Orbital navigator echoes for motion measurements in magnetic resonance imaging , 1995, Magnetic resonance in medicine.

[10]  Todd S. Sachs,et al.  The diminishing variance algorithm for real‐time reduction of motion artifacts in MRI , 1995, Magnetic resonance in medicine.

[11]  Yasser M. Kadah,et al.  Automatic suppression of spatially variant translational motion artifacts in magnetic resonance imaging , 1998, Proceedings 1998 International Conference on Image Processing. ICIP98 (Cat. No.98CB36269).

[12]  S J Riederer,et al.  Rapid autocorrection using prescan navigator echoes , 2000, Magnetic resonance in medicine.