Direct method of determining equivalent-step-index profiles for monomode fibres

A new technique for measuring equivalent-step-index profiles of monomode fibres is presented which involves measuring the mode spot-size directly as a function of wavelength, and compares favourably with measured profiles. Since characterisation of the fibre is derived from easily measured optical properties, knowledge of the actual profile and the modelling of the propagation characteristics from it is unnecessary.