Comparison of two actuation systems for laparoscopic surgical manipulators using motion analysis

BackgroundDuring surgery, all joints of the upper limbs, including shoulder, elbow, wrist, and finger, coordinate to complete a task. Hence, analysis of these joint movements during surgical manipulations is useful for the design of optimal hand-instrument interface. This study compared two types of surgical handheld manipulators with 6 degrees of freedom with different handle designs: one using a controlling wheel (fingertip control, FTC) and the other with a controlling joint (master slave control, MSC) in terms of ergonomics and movement efficiency.MethodsSeventeen subjects consisting of surgeons and medical students participated in the experiment. Each performed two standardized surgical tasks in a surgical simulator. A set of reflective markers were attached on the subjects’ upper limbs and the marker positions during the tasks were collected by a motion capture system for subsequent analysis of the trunk, shoulder, elbow, wrist, and fingers joint movements. The subjects also completed a Visual Analogue Scale-based questionnaire on their preference for the control mechanism and ease of handling.ResultsThe data showed that the manipulator with the MSC was more difficult to handle and resulted in larger range of movements, higher velocities, and accelerations in some joints than the manipulator with FTC mechanism. Use of the MSC manipulator also was accompanied by a higher error rate. Additionally, the subjects preferred the finger actuated manipulator and gave it a higher Visual Analogue Score for maneuverability.ConclusionsThe manipulator equipped with the MSC was ergonomically inferior; it was more difficult to handle and provided less precision, resulting in higher error rates than the FTC manipulator. This study also confirmed that motion analysis is useful for assessment of the design of handheld manipulators for endoscopic surgery.

[1]  Xudong Zhang,et al.  Determining finger segmental centers of rotation in flexion-extension based on surface marker measurement. , 2003, Journal of biomechanics.

[2]  C Disselhorst-Klug,et al.  A marker-based measurement procedure for unconstrained wrist and elbow motions. , 1999, Journal of biomechanics.

[3]  T. G. Frank,et al.  Influence of handle design on the surgeon's upper limb movements, muscle recruitment, and fatigue during endoscopic suturing , 2001, Surgical Endoscopy.

[4]  C. J. Snijders,et al.  Improvement of the laparoscopic needle holder based on new ergonomic guidelines , 2003, Surgical Endoscopy And Other Interventional Techniques.

[5]  R. Berguer,et al.  Surgical technology and the ergonomics of laparoscopic instruments , 1998, Surgical Endoscopy.

[6]  M. Alizadeh,et al.  Design of a marker-based human motion tracking system , 2007, Biomed. Signal Process. Control..

[7]  G S Rash,et al.  A demonstration of validity of 3-D video motion analysis method for measuring finger flexion and extension. , 1999, Journal of biomechanics.

[8]  Warren D. Smith,et al.  Ergonomic problems associated with laparoscopic surgery , 1999, Surgical Endoscopy.

[9]  E. Farthmann,et al.  Ergonomics: Requirements for Adjusting the Height of Laparoscopic Operating Tables , 2001, JSLS : Journal of the Society of Laparoendoscopic Surgeons.

[10]  Catherine Disselhorst-Klug,et al.  An upper body model for the kinematical analysis of the joint chain of the human arm. , 2006, Journal of biomechanics.

[11]  C. Giebmeyer,et al.  Monitor position in laparoscopic surgery , 2005, Surgical Endoscopy And Other Interventional Techniques.

[12]  Maedeh Borhani,et al.  Motion analysis as a tool for the evaluation of oculoplastic surgical skill: evaluation of oculoplastic surgical skill. , 2008, Archives of ophthalmology.

[13]  Ara Darzi,et al.  The relationship between motion analysis and surgical technical assessments. , 2002, American journal of surgery.

[14]  A. Darzi,et al.  The use of electromagnetic motion tracking analysis to objectively measure open surgical skill in the laboratory-based model. , 2001, Journal of the American College of Surgeons.

[15]  U Matern,et al.  Instruments for minimally invasive surgery: principles of ergonomic handles. , 1999, Surgical endoscopy.

[16]  A. Cuschieri,et al.  Rocker handle for endoscopic needle drivers. Technical and ergonomic evaluation by infrared motion analysis system. , 1999, Surgical endoscopy.

[17]  Fong-Chin Su,et al.  Feasibility of using a video-based motion analysis system for measuring thumb kinematics. , 2002, Journal of biomechanics.