Custom-made titanium devices as membranes for bone augmentation in implant treatment: Modeling accuracy of titanium products constructed with selective laser melting.

OBJECTIVE The purpose of this study was to verify the modeling accuracy of various products, and to produce custom-made devices for bone augmentation in individual patients requiring implantation. MATERIALS AND METHODS Two-(2D) and three-dimensional (3D) specimens and custom-made devices that were designed as membranes for guided bone regeneration (GBR) were produced using a computer-aided design (CAD) and rapid prototyping (RP) method. The CAD design was produced using a 3D printing machine and selective laser melting (SLM) with pure titanium (Ti) powder. The modeling accuracy was evaluated with regard to: the dimensional accuracy of the 2D and 3D specimens; the accuracy of pore structure of the 2D specimens; the accuracy of porosity of the 3D specimens; and the error between CAD design and the scanned real product by overlapped images. RESULTS The accuracy of the 2D and 3D specimens indicated precise results in various parameters, which were tolerant in ISO 2768-1. The error of overlapped images between the CAD and scanned data indicated that accuracy was sufficient for GBR. In integrating area of all devices, the maximum and average error were 292 and 139 μm, respectively. CONCLUSIONS High modeling accuracy can be achieved in various products using the CAD/RP-SLM method. These results suggest the possibility of clinical applications.

[1]  Seok-Hwan Cho,et al.  Mirror-image anterior crown fabrication with computer-aided design and rapid prototyping technology: a clinical report. , 2013, The Journal of prosthetic dentistry.

[2]  K. Bose,et al.  Principles and applications of Computer-Aided Design and Computer-Aided Manufacturing (CAD/CAM) technology in orthopaedics. , 1990, Annals of the Academy of Medicine, Singapore.

[3]  Rekow Ed A review of the developments in dental CAD/CAM systems. , 1992 .

[4]  Go Kimura,et al.  An attempt to calculate in silico disintegration time of tablets containing mefenamic acid, a low water-soluble drug. , 2013, Journal of pharmaceutical sciences.

[5]  R. Swanson,et al.  Digitally quantifying cerebral hemorrhage using Photoshop® and Image J , 2010, Journal of Neuroscience Methods.

[6]  Jorge Vicente Lopes da Silva,et al.  Dimensional error in selective laser sintering and 3D-printing of models for craniomaxillary anatomy reconstruction. , 2008, Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery.

[7]  Shuichi Matsuda,et al.  Developing a novel custom cutting guide for curved peri-acetabular osteotomy , 2013, International Orthopaedics.

[8]  Marcin Kozakiewicz,et al.  Accuracy of three-dimensional, paper-based models generated using a low-cost, three-dimensional printer. , 2014, Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery.

[9]  Adel Abou-ElFetouh,et al.  Clinical and radiographic evaluation of a computer-generated guiding device in bilateral sagittal split osteotomies. , 2014, Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery.

[10]  Timothy Douglas,et al.  Rapid prototyping: porous titanium alloy scaffolds produced by selective laser melting for bone tissue engineering. , 2009, Tissue engineering. Part C, Methods.

[11]  Tadashi Kokubo,et al.  Pore throat size and connectivity determine bone and tissue ingrowth into porous implants: three-dimensional micro-CT based structural analyses of porous bioactive titanium implants. , 2006, Biomaterials.

[12]  P. Lipinski,et al.  Fatigue behavior of thin-walled grade 2 titanium samples processed by selective laser melting. Application to life prediction of porous titanium implants. , 2013, Journal of the mechanical behavior of biomedical materials.

[13]  Lewis Mullen,et al.  Selective Laser Melting: a regular unit cell approach for the manufacture of porous, titanium, bone in-growth constructs, suitable for orthopedic applications. , 2009, Journal of biomedical materials research. Part B, Applied biomaterials.

[14]  R W Pho,et al.  Computer applications in orthopaedics. , 1990, Annals of the Academy of Medicine, Singapore.

[15]  J R Calamia Advances in computer-aided design and computer-aided manufacture technology. , 1996, The Journal of the Philippine Dental Association.

[16]  Yuri Pevzner,et al.  Fragment-Based Docking: Development of the CHARMMing Web User Interface as a Platform for Computer-Aided Drug Design , 2014, J. Chem. Inf. Model..

[17]  J. Weng,et al.  Preparation and characterization of a novel porous titanium scaffold with 3D hierarchical porous structures , 2011, Journal of materials science. Materials in medicine.

[18]  Minna Kellomäki,et al.  A review of rapid prototyping techniques for tissue engineering purposes , 2008, Annals of medicine.

[19]  Alberto Sanchez-Lite,et al.  Novel Ergonomic Postural Assessment Method (NERPA) Using Product-Process Computer Aided Engineering for Ergonomic Workplace Design , 2013, PloS one.

[20]  P. Trisi,et al.  Vertical ridge augmentation using a membrane technique associated with osseointegrated implants. , 1994, The International journal of periodontics & restorative dentistry.

[21]  P. Soucacos,et al.  Three-dimensional computerized selection of hip prostheses in patients with congenital dislocated hips. , 2001, Orthopedics.

[22]  Balvinder S Khambay,et al.  How accurate are rapid prototyped (RP) final orthognathic surgical wafers? A pilot study. , 2014, The British journal of oral & maxillofacial surgery.

[23]  M. Giger,et al.  Anniversary paper: History and status of CAD and quantitative image analysis: the role of Medical Physics and AAPM. , 2008, Medical physics.

[24]  J. Cano,et al.  Osteogenic alveolar distraction: a review of the literature. , 2006, Oral surgery, oral medicine, oral pathology, oral radiology, and endodontics.

[25]  X. Weng,et al.  Potential Use of Porous Titanium–Niobium Alloy in Orthopedic Implants: Preparation and Experimental Study of Its Biocompatibility In Vitro , 2013, PloS one.

[26]  Tadashi Kokubo,et al.  Mechanical properties and osteoconductivity of porous bioactive titanium. , 2005, Biomaterials.

[27]  Joan E Sanders,et al.  Central fabrication: carved positive assessment , 2011, Prosthetics and orthotics international.

[28]  V. Poroikov,et al.  Computer-aided design and discovery of protein–protein interaction inhibitors as agents for anti-HIV therapy , 2014, SAR and QSAR in environmental research.

[29]  Maryellen L Giger,et al.  Potential effect of different radiologist reporting methods on studies showing benefit of CAD. , 2008, Academic radiology.

[30]  Scott J Hollister,et al.  A paradigm for the development and evaluation of novel implant topologies for bone fixation: implant design and fabrication. , 2012, Journal of biomechanics.

[31]  André Luiz Jardini,et al.  Microstructure and mechanical behavior of porous Ti-6Al-4V parts obtained by selective laser melting. , 2013, Journal of the mechanical behavior of biomedical materials.

[32]  Duke Es The status of CAD/CAM in restorative dentistry. , 2001 .

[33]  Lilian Costa Anami,et al.  Removable partial dentures: use of rapid prototyping. , 2014, Journal of prosthodontics : official journal of the American College of Prosthodontists.

[34]  Takashi Nakamura,et al.  Bioactive Ti metal analogous to human cancellous bone: Fabrication by selective laser melting and chemical treatments. , 2011, Acta biomaterialia.

[35]  D. Silva,et al.  Dimensional error of selective laser sintering, three-dimensional printing and PolyJet models in the reproduction of mandibular anatomy. , 2009, Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery.

[36]  Fabio Napolitano,et al.  Measurement of meat color using a computer vision system. , 2013, Meat science.

[37]  Dennis J Fasbinder,et al.  Computerized technology for restorative dentistry. , 2013, American journal of dentistry.

[38]  Gamal M Dahab,et al.  Digital quantification of fibrosis in liver biopsy sections: Description of a new method by Photoshop software , 2004, Journal of gastroenterology and hepatology.