Pliant Active and Reactive Power Control for Grid-Interactive Converters Under Unbalanced Voltage Dips

During voltage dips continuous power delivery from distributed generation systems to the grid is desirable for the purpose of grid support. In order to facilitate the control of inverter-based distributed power generation adapted to the expected change of grid requirements, generalized power control strategies based on symmetric-sequence components are proposed in this paper, aiming to manipulate the delivered instantaneous power under unbalanced voltage dips. It is shown that active and reactive power can be independently controlled with two individually adaptable parameters. By changing these parameters, the relative amplitudes of oscillating power can be smoothly regulated, as well as the peak values of three-phase grid currents. As a result, the power control of grid-interactive inverters becomes quite flexible and adaptable to various grid requirements or design constraints. Furthermore, two strategies for simultaneous active and reactive power control are proposed that preserve flexible controllability; an application example is given to illustrate the simplicity and adaptability of the proposed strategies for online optimization control. Finally, experimental results are provided that verify the proposed power control.

[1]  B. Banerjee,et al.  Assessment of Voltage Unbalance , 2001, IEEE Power Engineering Review.

[2]  T.A. Lipo,et al.  A control scheme in hybrid synchronous-stationary frame for PWM AC/DC converter under generalized unbalanced operating conditions , 2004, Conference Record of the 2004 IEEE Industry Applications Conference, 2004. 39th IAS Annual Meeting..

[3]  M. J. Samotyj,et al.  Voltage sags in industrial systems , 1991, Conference Record. Industrial and Commercial Power Systems Technical Conference 1991.

[4]  Frede Blaabjerg,et al.  Proportional-resonant controllers and filters for grid-connected voltage-source converters , 2006 .

[5]  Donald Grahame Holmes,et al.  Stationary frame current regulation of PWM inverters with zero steady state error , 1999, 30th Annual IEEE Power Electronics Specialists Conference. Record. (Cat. No.99CH36321).

[6]  Donald Grahame Holmes,et al.  Grid current regulation of a three-phase voltage source inverter with an LCL input filter , 2002, 2002 IEEE 33rd Annual IEEE Power Electronics Specialists Conference. Proceedings (Cat. No.02CH37289).

[7]  Fang Zheng Peng,et al.  Reactive power and harmonic compensation based on the generalized instantaneous reactive power theory for three-phase power systems , 1996 .

[8]  H. Pinheiro,et al.  Design and Implementation of a Robust Current Controller for VSI Connected to the Grid Through an LCL Filter , 2009, IEEE Transactions on Power Electronics.

[9]  M. Liserre,et al.  Evaluation of Current Controllers for Distributed Power Generation Systems , 2009, IEEE Transactions on Power Electronics.

[10]  Fei Wang,et al.  Active power control strategies for inverter-based distributed power generation adapted to grid-fault ride-through requirements , 2009, 2009 13th European Conference on Power Electronics and Applications.

[11]  Li Ran,et al.  Unbalanced Grid Fault Ride-Through Control for a Wind Turbine Inverter , 2007, 2007 IEEE Industry Applications Annual Meeting.

[12]  S.K. Panda,et al.  Analysis of the Instantaneous Power Flow for Three-Phase PWM Boost Rectifier Under Unbalanced Supply Voltage Conditions , 2008, IEEE Transactions on Power Electronics.

[13]  Sanjib Kumar Panda,et al.  An Output-Power-Control Strategy for a Three-Phase PWM Rectifier Under Unbalanced Supply Conditions , 2008, IEEE Transactions on Industrial Electronics.

[14]  Frede Blaabjerg,et al.  Proportionalresonant controllers and filters for gridconnected voltagesource converters , 2006 .

[15]  Frede Blaabjerg,et al.  Flexible Active Power Control of Distributed Power Generation Systems During Grid Faults , 2007, IEEE Transactions on Industrial Electronics.

[16]  M. Liserre,et al.  Reactive Power Control for Improving Wind Turbine System Behavior Under Grid Faults , 2009, IEEE Transactions on Power Electronics.

[17]  G. Joos,et al.  A Fast and Accurate Synchronization Technique for Extraction of Symmetrical Components , 2009, IEEE Transactions on Power Electronics.

[18]  Hirofumi Akagi,et al.  Instantaneous power theory and applications to power conditioning , 2007 .

[19]  Math Bollen,et al.  Characteristic of voltage dips (sags) in power systems , 2000 .

[20]  Wilsun Xu,et al.  Analysis of faulted power systems by phase coordinates , 1998 .

[21]  Fei Wang,et al.  High Performance Stationary Frame Filters for Symmetrical Sequences or Harmonics Separation Under a Variety of Grid Conditions , 2009, 2009 Twenty-Fourth Annual IEEE Applied Power Electronics Conference and Exposition.