Performance Analysis and Test of a Small-Scale Natural Circulation Vertical Evaporator
暂无分享,去创建一个
In this study, an effort has been made to analyze the subcooled boiling heat transfer in a natural circulation vertical evaporator. To verify the analysis, a small-scale model was made and tested. The friction correlation by Ueda, void fraction and quality correlation by Saha and Zuber along with the superposition heat transfer model by Rohsenow yielded a satisfactory agreement with the model test data. The analysis was extended to simulate a 1 ton/day concentration system. Comparison with the test results of 1 ton/day prototype revealed that the data were overpredicted by 13%. The capacity of the prototype was 1.2 ton/day with COP of 5.77.
[1] Satish G. Kandlikar,et al. Heat Transfer Characteristics in Partial Boiling, Fully Developed Boiling, and Significant Void Flow Regions of Subcooled Flow Boiling , 1997, Fluids Engineering.
[2] Hirohisa Matsumura,et al. On the Conditions of Incipient Subcooled-Boiling with Forced Convection , 1963 .
[3] W. Rohsenow,et al. The Determination of Forced-Convection Surface-Boiling Heat Transfer , 1964 .