Wireless tissue palpation: Head characterization to improve tumor detection in soft tissue

For surgeons performing open procedures, the sense of touch is a valuable tool to directly access buried structures and organs, to identify their margins, detect tumors, and prevent undesired cuts. Minimally invasive surgical procedures provide great benefits for patients; however, they hinder the surgeon's ability to directly manipulate the tissue. In our previous work, we developed a Wireless Palpation Probe (WPP) to restore tissue palpation in Minimally Invasive Surgery (MIS) by creating a real-time stiffness distribution map of the target tissue. The WPP takes advantage of a field-based magnetic localization algorithm to measure its position, orientation, and tissue indentation depth, in addition to a barometric sensor measuring indentation tissue pressure. However, deformations of both the tissue and the silicone material used to cover the pressure sensors introduce detrimental nonlinearities in sensor measurements. In this work, we calibrated and characterized different diameter WPP heads with a new design allowing exchangeability and disposability of the probe head. Benchtop trials showed that this method can effectively reduce error in sensor pressure measurements up to 5% with respect to the reference sensor. Furthermore, we studied the effect of the head diameter on the device's spatial resolution in detecting tumor simulators embedded into silicone phantoms. Overall, the results showed a tumor detection rate over 90%, independent of the head diameter, when an indentation depth of 5 mm is applied on the tissue simulator.

[1]  V. Velanovich Laparoscopic vs open surgery , 2009, Surgical Endoscopy.

[2]  M. T. Perri,et al.  Initial Evaluation of a Tactile/Kinesthetic Force Feedback System for Minimally Invasive Tumor Localization , 2010, IEEE/ASME Transactions on Mechatronics.

[3]  Pietro Valdastri,et al.  Real-Time Pose Detection for Magnetic Medical Devices , 2013, IEEE Transactions on Magnetics.

[4]  T. Ortmaier,et al.  The touch and feel in minimally invasive surgery , 2005, IEEE International Workshop on Haptic Audio Visual Environments and their Applications.

[5]  Britt M. Andersson,et al.  Prostate tissue stiffness as measured with a resonance sensor system: a study on silicone and human prostate tissue in vitro , 2006, Medical and Biological Engineering and Computing.

[6]  Masakatsu G. Fujie,et al.  Integration of a Miniaturised Triaxial Force Sensor in a Minimally Invasive Surgical Tool , 2006, IEEE Transactions on Biomedical Engineering.

[7]  Pietro Valdastri,et al.  Wireless Tissue Palpation: Characterization of the Probe Head to Improve Detection of Tumors in Soft Tissue , 2014 .

[8]  Blake Hannaford,et al.  Biomechanical properties of abdominal organs in vivo and postmortem under compression loads. , 2008, Journal of biomechanical engineering.

[9]  Marc O Schurr,et al.  Review on aspects of artificial tactile feedback in laparoscopic surgery. , 2009, Medical engineering & physics.

[10]  G. G. Stokes "J." , 1890, The New Yale Book of Quotations.

[11]  Matteo Ravaioli,et al.  Impact of subcentimeter margin on outcome after hepatic resection for colorectal metastases: a meta-regression approach. , 2012, Surgery.

[12]  Robert D. Howe,et al.  Remote palpation technology , 1995 .

[13]  M. Hashizume,et al.  Early experiences of endoscopic procedures in general surgery assisted by a computer-enhanced surgical system , 2002, Surgical Endoscopy And Other Interventional Techniques.

[14]  Allison M. Okamura,et al.  Human vs. robotic tactile sensing: Detecting lumps in soft tissue , 2010, 2010 IEEE Haptics Symposium.

[15]  R.V. Patel,et al.  Robotic suturing forces in the presence of haptic feedback and sensory substitution , 2005, Proceedings of 2005 IEEE Conference on Control Applications, 2005. CCA 2005..

[16]  R. Reuben,et al.  Measurement of tissue mechanical characteristics to distinguish between benign and malignant prostatic disease. , 2005, Urology.

[17]  Miss A.O. Penney (b) , 1974, The New Yale Book of Quotations.

[18]  Yating Hu,et al.  Bioinspired 3-D Tactile Sensor for Minimally Invasive Surgery , 2010, Journal of Microelectromechanical Systems.

[19]  A. Cuschieri Whither minimal access surgery: tribulations and expectations. , 1995, American journal of surgery.

[20]  Simon Phipps,et al.  Prostate tissue stiffness as measured with a resonance sensor system: a study on silicone and human prostate tissue in vitro , 2006, Medical and Biological Engineering and Computing.

[21]  Pietro Valdastri,et al.  Wireless Tissue Palpation for Intraoperative Detection of Lumps in the Soft Tissue , 2014, IEEE Transactions on Biomedical Engineering.

[22]  P. Dario,et al.  An advanced robot system for automated diagnostic tasks through palpation , 1988, IEEE Transactions on Biomedical Engineering.

[23]  Chang Liu,et al.  Development of polyimide flex-ible tactile sensor skin , 2003 .

[24]  Nigel H. Lovell,et al.  A review of tactile sensing technologies with applications in biomedical engineering , 2012 .

[25]  L.D. Seneviratne,et al.  State-of-the-Art in Force and Tactile Sensing for Minimally Invasive Surgery , 2008, IEEE Sensors Journal.

[26]  Robert D. Howe,et al.  Extracting Features from Tactile Maps , 1999, MICCAI.

[27]  M. Shimojo,et al.  Spatial filtering characteristic of elastic cover for tactile sensor , 1994, Proceedings of the 1994 IEEE International Conference on Robotics and Automation.