Orthogonal Field Calibration Analysis for Myocardial Electrode Arrays Used in Defibrillation Studies

Mapping the myocardial electric field during a defibrillation pulse requires the recording of potential differences between electrodes. The field is then calculated from these quantities and the corresponding calibration matrix. One straightforward calibration technique involves alignment of a known electric field along each of the orthogonal axes of an electrode array and recording the resulting potential differences. However, no results have been reported to support the efficacy of this technique. This study performs a detailed error analysis including a one-to-one comparison to a precision calibration technique, and quantitatively establishes the efficacy of the orthogonal field technique.

[1]  J. Rosborough,et al.  Intracardiac voltage gradients during transthoracic defibrillation: implications for postshock myocardial injury. , 2005, Academic emergency medicine : official journal of the Society for Academic Emergency Medicine.

[2]  I. Efimov,et al.  Mechanisms of superiority of ascending ramp waveforms: new insights into mechanisms of shock-induced vulnerability and defibrillation. , 2005, American journal of physiology. Heart and circulatory physiology.

[3]  D. Deno,et al.  A Percutaneous Catheter‐Based System for the Measurement of Potential Gradients Applicable to the Study of Transthoracic Defibrillation , 2007, Pacing and clinical electrophysiology : PACE.

[4]  Ellen J. Kim-Van Housen,et al.  Calibrated single-plunge bipolar electrode array for mapping myocardial vector fields in three dimensions during high-voltage transthoracic defibrillation , 2001, IEEE Transactions on Biomedical Engineering.

[5]  Andrew E Pollard,et al.  Measuring surface potential components necessary for transmembrane current computation using microfabricated arrays. , 2005, American journal of physiology. Heart and circulatory physiology.

[6]  Raymond E Ideker,et al.  Do clinically relevant transthoracic defibrillation energies cause myocardial damage and dysfunction? , 2003, Resuscitation.

[7]  R A Smith,et al.  Is There an Optimal Electrode Pad Size to Maximize Intracardiac Current in Transthoracic Defibrillation? , 1997, Pacing and clinical electrophysiology : PACE.

[8]  R Plonsey,et al.  Mechanism of cardiac defibrillation in open-chest dogs with unipolar DC-coupled simultaneous activation and shock potential recordings. , 1990, Circulation.

[9]  P D Wolf,et al.  The potential gradient field created by epicardial defibrillation electrodes in dogs. , 1986, Circulation.