Aerosol delivery during mechanical ventilation: from basic techniques to new devices.

Pressurized metered-dose inhalers (pMDIs) and nebulizers are routinely employed for aerosol delivery in mechanically ventilated patients. A significant proportion of the aerosol deposits in the ventilator circuit and artificial airway, thereby reducing the inhaled drug mass. Factors influencing aerosol delivery during mechanical ventilation differ from those in spontaneously breathing patients. The English language literature on aerosol delivery during mechanical ventilation was reviewed. Marked variations in the efficiency of drug delivery with pMDIs and nebulizers occur due to differences in the technique of administration. Careful attention to five factors, viz., the aerosol generator, aerosol particle size, conditions in the ventilator circuit, artificial airway, and ventilator parameters, is necessary to optimize aerosol delivery during mechanical ventilation. Factors influencing drug delivery during NPPV are not well understood, and the efficiency of aerosol delivery in this setting is lower than that during invasive mechanical ventilaiton. With an optimal technique of administration the efficiency of aerosol delivery during mechanical ventilation is similar to that achieved during spontaneous breathing. Further research is needed to optimize aerosol delivery during NPPV.

[1]  J. L. Rau,et al.  A comparison of inline MDI actuators for delivery of a beta agonist and a corticosteroid with a mechanically ventilated lung model , 1998 .

[2]  J. Wedzicha,et al.  Non-invasive positive pressure ventilation for treatment of respiratory failure due to exacerbations of chronic obstructive pulmonary disease. , 2004, The Cochrane database of systematic reviews.

[3]  D. Hess,et al.  In vitro evaluation of aerosol bronchodilator delivery during noninvasive positive pressure ventilation: Effect of ventilator settings and nebulizer position , 2002, Critical care medicine.

[4]  I Gonda,et al.  Droplets produced by medical nebulizers. Some factors affecting their size and solute concentration. , 1990, Chest.

[5]  R Dhand,et al.  Special problems in aerosol delivery: artificial airways. , 2000, Respiratory care.

[6]  A. Bidani,et al.  Bronchodilator therapy with metered-dose inhaler and spacer versus nebulizer in mechanically ventilated patients: comparison of magnitude and duration of response. , 2000, Respiratory care.

[7]  M. Newhouse,et al.  Optimal delivery of aerosols from metered dose inhalers. , 1981, Chest.

[8]  Bruce K Rubin,et al.  Optimizing aerosol delivery by pressurized metered-dose inhalers. , 2005, Respiratory care.

[9]  H. Steckel,et al.  Factors affecting aerosol performance during nebulization with jet and ultrasonic nebulizers. , 2003, European journal of pharmaceutical sciences : official journal of the European Federation for Pharmaceutical Sciences.

[10]  M. Newhouse,et al.  Pulmonary aerosol deposition in chronic bronchitis: intermittent positive pressure breathing versus quiet breathing. , 1977, The American review of respiratory disease.

[11]  H. Lennernäs,et al.  Miniaturized nebulization catheters: a new approach for delivery of defined aerosol doses to the rat lung. , 2002, Journal of aerosol medicine : the official journal of the International Society for Aerosols in Medicine.

[12]  S. Newman,et al.  How well do in vitro particle size measurements predict drug delivery in vivo? , 1998, Journal of aerosol medicine : the official journal of the International Society for Aerosols in Medicine.

[13]  C. Guérin,et al.  Inhaled fenoterol-ipratropium bromide in mechanically ventilated patients with chronic obstructive pulmonary disease. , 1999, American journal of respiratory and critical care medicine.

[14]  F. Millard,et al.  The therapeutic use of ultrasonic nebulizers in acute asthma. , 1994, Respiratory medicine.

[15]  T. O'riordan,et al.  Aerosol deposition in mechanically ventilated patients. Optimizing nebulizer delivery. , 1994, American journal of respiratory and critical care medicine.

[16]  D. Ikle,et al.  A comparison of commercial jet nebulizers. , 1994, Chest.

[17]  M. O'Doherty,et al.  Delivery of ultrasonic nebulized aerosols to a lung model during mechanical ventilation. , 1993, The American review of respiratory disease.

[18]  N. Sheahan,et al.  Deposition of pressurised aerosols in the human respiratory tract. , 1981, Thorax.

[19]  D. Hess The mask for noninvasive ventilation: principles of design and effects on aerosol delivery. , 2007, Journal of aerosol medicine : the official journal of the International Society for Aerosols in Medicine.

[20]  J. Chevrolet,et al.  Helium-oxygen versus air-oxygen noninvasive pressure support in decompensated chronic obstructive disease: A prospective, multicenter study* , 2003, Critical care medicine.

[21]  G F Alvine,et al.  Disposable jet nebulizers. How reliable are they? , 1992, Chest.

[22]  J. Hughes,et al.  Effects of nebulizer mode and position in a mechanical ventilator circuit on dose efficiency , 1987 .

[23]  R. Dhand,et al.  Effective inhaled drug administration to mechanically ventilated patients , 2007, Expert opinion on drug delivery.

[24]  G. Shenfield,et al.  The fate of nebulized salbutamol (albuterol) administered by intermittent positive pressure respiration to asthmatic patients. , 1973, The American review of respiratory disease.

[25]  C. Leach,et al.  Improved airway targeting with the CFC-free HFA-beclomethasone metered-dose inhaler compared with CFC-beclomethasone. , 1998, The European respiratory journal.

[26]  M. Bishop,et al.  Metered dose inhaler aerosol characteristics are affected by the endotracheal tube actuator/adapter used. , 1990, Anesthesiology.

[27]  Robert M. Kacmarek,et al.  In vitro evaluation of aerosol bronchodilator delivery during mechanical ventilation: pressure-control vs. volume control ventilation , 2003, Intensive Care Medicine.

[28]  P Camner,et al.  Deposition in asthmatics of particles inhaled in air or in helium-oxygen. , 1993, The American review of respiratory disease.

[29]  D. Hess,et al.  Albuterol delivery during noninvasive ventilation. , 2005, Respiratory care.

[30]  R. J. Clark Bronchodilator therapy. , 1976, Arizona medicine.

[31]  C. Camargo,et al.  The Effect of Heliox on Nebulizer Function Using a β-Agonist Bronchodilator , 1999 .

[32]  J. Nicolás,et al.  Early noninvasive ventilation averts extubation failure in patients at risk: a randomized trial. , 2006, American journal of respiratory and critical care medicine.

[33]  J. L. Rau,et al.  Evaluation of a reservoir device for metered-dose bronchodilator delivery to intubated adults. An in vitro study. , 1992, Chest.

[34]  R. Perry,et al.  Nebulizer function during mechanical ventilation. , 1992, The American review of respiratory disease.

[35]  C. Camargo,et al.  The effect of heliox on nebulizer function using a beta-agonist bronchodilator. , 1999, Chest.

[36]  M. Tobin,et al.  Bronchodilator delivery by metered-dose inhaler in ventilator-supported patients. , 1995, American journal of respiratory and critical care medicine.

[37]  M. Tobin,et al.  Improvement in aerosol delivery with helium-oxygen mixtures during mechanical ventilation. , 2001, American journal of respiratory and critical care medicine.

[38]  A. Harf,et al.  Optimization of aerosol deposition by pressure support in children with cystic fibrosis: an experimental and clinical study. , 2000, American journal of respiratory and critical care medicine.

[39]  M. Svartengren,et al.  Human lung deposition of particles suspended in air or in helium/oxygen mixture. , 1989, Experimental lung research.

[40]  M. Newhouse,et al.  Efficiency of bronchodilator aerosol delivery to the lungs from the metered dose inhaler in mechanically ventilated patients. A study comparing four different actuator devices. , 1994, Chest.

[41]  M. Bishop,et al.  Delivery efficiency of metered dose aerosols given via endotracheal tubes. , 1989, Anesthesiology.

[42]  P. Sterk,et al.  Physical properties of aerosols produced by several jet- and ultrasonic nebulizers. , 1984, Bulletin europeen de physiopathologie respiratoire.

[43]  E. Ahlgren Aerosol drug therapy. , 1970, International anesthesiology clinics.

[44]  J. L. Rau Design principles of liquid nebulization devices currently in use. , 2002, Respiratory care.

[45]  P. Marik,et al.  A comparison of bronchodilator therapy delivered by nebulization and metered-dose inhaler in mechanically ventilated patients. , 1999, Chest.

[46]  M. O'Doherty,et al.  Comparison of jet and ultrasonic nebulizer pulmonary aerosol deposition during mechanical ventilation. , 1997, The European respiratory journal.

[47]  G. Smaldone,et al.  Aerosol delivery and modern mechanical ventilation: in vitro/in vivo evaluation. , 2003, American journal of respiratory and critical care medicine.

[48]  G. Smaldone,et al.  Choice of mechanical ventilator: influence on nebulizer performance , 1993 .

[49]  M. Dolovich Influence of inspiratory flow rate, particle size, and airway caliber on aerosolized drug delivery to the lung. , 2000, Respiratory care.

[50]  A. Bersten,et al.  Aerosol kinetics and bronchodilator efficacy during continuous positive airway pressure delivered by face mask. , 1997, Thorax.

[51]  W. Ar Heat and moisture exchangers. Structure and function. , 1998 .

[52]  I. Gonda,et al.  Targeting by deposition , 1992 .

[53]  R. Ahrens,et al.  The delivery of therapeutic aerosols through endotracheal tubes , 1986, Pediatric pulmonology.

[54]  M. Wysocki,et al.  Noninvasive versus conventional mechanical ventilation. An epidemiologic survey. , 2001, American journal of respiratory and critical care medicine.

[55]  M. O'Doherty,et al.  Aerosol deposition in mechanically ventilated patients. , 1994, American journal of respiratory and critical care medicine.

[56]  J. Wedzicha,et al.  Randomised controlled trial of nasal ventilation in acute ventilatory failure due to chronic obstructive airways disease , 1993, The Lancet.

[57]  P. Diot,et al.  Albuterol delivery in a model of mechanical ventilation. Comparison of metered-dose inhaler and nebulizer efficiency. , 1995, American journal of respiratory and critical care medicine.

[58]  M. Tobin,et al.  Bronchodilator delivery with metered-dose inhalers in mechanically-ventilated patients. , 1996, The European respiratory journal.

[59]  Dolovich Ma Influence of inspiratory flow rate, particle size, and airway caliber on aerosolized drug delivery to the lung. , 2000 .

[60]  P. Thompson,et al.  Hydrofluoroalkane-134a beclomethasone dipropionate, 400 microg, is as effective as chlorofluorocarbon beclomethasone dipropionate, 800 microg, for the treatment of moderate asthma. , 1999, Chest.

[61]  S. Nava,et al.  Salbutamol delivery during non-invasive mechanical ventilation in patients with chronic obstructive pulmonary disease: a randomized, controlled study , 2001, Intensive Care Medicine.

[62]  iorgio,et al.  NONINVASIVE VENTILATION FOR ACUTE EXACERBATIONS OF CHRONIC OBSTRUCTIVE PULMONARY DISEASE , 2000 .

[63]  M. Tobin,et al.  Reconciling in vitro and in vivo measurements of aerosol delivery from a metered-dose inhaler during mechanical ventilation and defining efficiency-enhancing factors. , 1999, American journal of respiratory and critical care medicine.

[64]  M. O'Doherty,et al.  Effect of a spacer on pulmonary aerosol deposition from a jet nebuliser during mechanical ventilation. , 1995, Thorax.

[65]  M. O'Doherty,et al.  Delivery of a nebulized aerosol to a lung model during mechanical ventilation. Effect of ventilator settings and nebulizer type, position, and volume of fill. , 1992, The American review of respiratory disease.

[66]  N. Hill,et al.  Randomized, prospective trial of noninvasive positive pressure ventilation in acute respiratory failure. , 1995, American journal of respiratory and critical care medicine.

[67]  D. Habib,et al.  Effect of Helium‐Oxygen on Delivery of Albuterol in a Pediatric, Volume‐Cycled, Ventilated Lung Model , 1999, Pharmacotherapy.

[68]  R. Dhand Inhalation therapy in invasive and noninvasive mechanical ventilation , 2007, Current opinion in critical care.

[69]  D. Hess,et al.  Medication nebulizer performance. Effects of diluent volume, nebulizer flow, and nebulizer brand. , 1996, Chest.

[70]  M. Tobin,et al.  Aerosol delivery from a metered-dose inhaler during mechanical ventilation. An in vitro model. , 1996, American journal of respiratory and critical care medicine.

[71]  R. Dhand,et al.  Maximizing aerosol delivery during mechanical ventilation: go with the flow and go slow , 2003, Intensive Care Medicine.

[72]  M. Tobin,et al.  Dose-response to bronchodilator delivered by metered-dose inhaler in ventilator-supported patients. , 1996, American journal of respiratory and critical care medicine.

[73]  R. Dhand Aerosol therapy during mechanical ventilation: getting ready for prime time. , 2003, American journal of respiratory and critical care medicine.

[74]  C. Pollack,et al.  Treatment of acute bronchospasm with beta-adrenergic agonist aerosols delivered by a nasal bilevel positive airway pressure circuit. , 1995, Annals of emergency medicine.

[75]  W. Finlay,et al.  Overcoming the adverse effect of humidity in aerosol delivery via pressurized metered-dose inhalers during mechanical ventilation. , 2000, American journal of respiratory and critical care medicine.

[76]  Jolyon P. Mitchell,et al.  The delivery of chlorofluorocarbon-propelled versus hydrofluoroalkane-propelled beclomethasone dipropionate aerosol to the mechanically ventilated patient: a laboratory study. , 2003, Respiratory care.

[77]  M. Tobin,et al.  Inhaled bronchodilator therapy in mechanically ventilated patients. , 1997, American journal of respiratory and critical care medicine.

[78]  E. Kondili,et al.  Duration of salbutamol-induced bronchodilation delivered by metered-dose inhaler in mechanically ventilated COPD patients. , 2001, Monaldi archives for chest disease = Archivio Monaldi per le malattie del torace.

[79]  P. Artursson,et al.  A miniaturized nebulization catheter for improved gene delivery to the mouse lung , 2005, The journal of gene medicine.

[80]  R. Dhand Nebulizers that use a vibrating mesh or plate with multiple apertures to generate aerosol. , 2002, Respiratory care.