Local Pulse Wave Detection Using Continuous Wave Radar Systems

Although a lot of research has been done into radar-based heartbeat detection over the past few years, it is still unknown which physiological effects truly underlie these measurement signals. This paper investigates the cardiovascular system, as well as the effects due to the antenna characteristics, and establishes a connection to the variety of heartbeat signals that can be found in comparable publications. For the first time, the cause of the diverging signal shapes is researched, revealing the locally specific pulse wave curves named sphygmograms. Three different types are investigated: the carotid, the venous, and the ventricle sphygmogram. Verification of the measured signal shapes is ensured by a laser sensor. Afterward, the influence of the filtering on the sphygmograms is researched, as well as the influence of the antenna characteristics on the radar signal. Finally, all novel insights are combined to substantiate the variety of published heartbeat signal curves.

[1]  Reports of Medical Cases, Selected with a View of Illustrating the Symptoms and Cure of Diseases, by a Reference to Morbid Anatomy , 1831, The Medico-Chirurgical Review.

[2]  Alexander Koelpin,et al.  Six-Port Based Interferometry for Precise Radar and Sensing Applications , 2016, Sensors.

[3]  V. L. Clark,et al.  Clinical Methods: The History, Physical, and Laboratory Examinations , 1990 .

[4]  Orrin Devinsky,et al.  Pulmonary and cardiac pathology in sudden unexpected death in epilepsy (SUDEP) , 2017, Epilepsy & Behavior.

[5]  Robert Weigel,et al.  Advanced template matching algorithm for instantaneous heartbeat detection using continuous wave radar systems , 2017, 2017 First IEEE MTT-S International Microwave Bio Conference (IMBIOC).

[6]  Th. Pasch,et al.  Lehrbuch der Physiologie in Einzeldarstellungen , 1971 .

[7]  Robert Weigel,et al.  Instantaneous heartbeat detection using a cross-correlation based template matching for continuous wave radar systems , 2016, 2016 IEEE Topical Conference on Wireless Sensors and Sensor Networks (WiSNet).

[8]  Robert Weigel,et al.  Intelligent signal processing routine for instantaneous heart rate detection using a Six-Port microwave interferometer , 2015, 2015 International Symposium on Intelligent Signal Processing and Communication Systems (ISPACS).

[9]  Jenshan Lin,et al.  Vital sign radars: Past, present, and future , 2014, WAMICON 2014.

[10]  T. Steiner,et al.  Intensive Care Management of Acute Stroke: General Management , 2009, International journal of stroke : official journal of the International Stroke Society.

[11]  Changzhan Gu,et al.  Doppler radar vital sign detection with random body movement cancellation based on adaptive phase compensation , 2013, 2013 IEEE MTT-S International Microwave Symposium Digest (MTT).

[12]  K. Holldack,et al.  Atlas und Kurzgefasstes Lehrbuch der Phonokardiographie und verwandter Untersuchungsmethoden , 1956 .

[13]  J. Perloff,et al.  The physiologic mechanisms of cardiac and vascular physical signs. , 1983, Journal of the American College of Cardiology.

[14]  I. Ya. Immoreev,et al.  Ultrawideband radars: Features and capabilities , 2009 .

[15]  Alexander Koelpin,et al.  Microwave interferometer radar-based vital sign detection for driver monitoring syst , 2015, 2015 IEEE MTT-S International Conference on Microwaves for Intelligent Mobility (ICMIM).

[16]  Chao-Hsiung Tseng,et al.  Compact 24-GHz Doppler radar module for non-contact human vital-sign detection , 2016, 2016 International Symposium on Antennas and Propagation (ISAP).

[17]  J. Levick,et al.  An Introduction to Cardiovascular Physiology , 2009 .

[18]  Changzhi Li,et al.  A Review on Recent Advances in Doppler Radar Sensors for Noncontact Healthcare Monitoring , 2013, IEEE Transactions on Microwave Theory and Techniques.

[19]  W. Nichols,et al.  McDonald's Blood Flow in Arteries: Theoretical, Experimental and Clinical Principles , 1998 .

[20]  Richard J Charnigo,et al.  Primary Prevention of Sudden Cardiac Death Early Post-Myocardial Infarction: Root Cause Analysis for Implantable Cardioverter–Defibrillator Failure and Currently Available Options , 2017, Circulation. Arrhythmia and electrophysiology.

[21]  Changzhi Li,et al.  A Review on Recent Progress of Portable Short-Range Noncontact Microwave Radar Systems , 2017, IEEE Transactions on Microwave Theory and Techniques.

[22]  Shiqian Chen,et al.  Accurate Measurement in Doppler Radar Vital Sign Detection Based on Parameterized Demodulation , 2017, IEEE Transactions on Microwave Theory and Techniques.

[23]  Kozo Hirata,et al.  Age-Related Changes in Carotid Artery Flow and Pressure Pulses: Possible Implications for Cerebral Microvascular Disease , 2006, Stroke.

[24]  Robert Weigel,et al.  Six-Port Radar Sensor for Remote Respiration Rate and Heartbeat Vital-Sign Monitoring , 2013, IEEE Transactions on Microwave Theory and Techniques.

[25]  K Mostov,et al.  Medical applications of shortwave FM radar: remote monitoring of cardiac and respiratory motion. , 2010, Medical physics.

[26]  Sneh Anand,et al.  Application of wavelets based multiresolution analysis to detect relevant points of interest from finger-tip photoplethesmography and pressure signal from the radial artery , 2008, 2008 Cairo International Biomedical Engineering Conference.

[27]  Pierre-Yves Lagrée,et al.  The dicrotic notch analyzed by a numerical model , 2016, Comput. Biol. Medicine.

[28]  Xiaomeng Gao,et al.  Data-Based Quadrature Imbalance Compensation for a CW Doppler Radar System , 2013, IEEE Transactions on Microwave Theory and Techniques.

[29]  G. du Boulay Pädiatrische radiologie. Lehrbuch in 2 bänden , 1974 .

[30]  Willis J. Tompkins,et al.  A Real-Time QRS Detection Algorithm , 1985, IEEE Transactions on Biomedical Engineering.

[31]  J.C. Lin Noninvasive microwave measurement of respiration , 1975, Proceedings of the IEEE.

[32]  H. Moseley,et al.  Capnometry and anaesthesia , 1992, Canadian journal of anaesthesia = Journal canadien d'anesthesie.

[33]  Jenshan Lin,et al.  A Ka-Band Low Power Doppler Radar System for Remote Detection of Cardiopulmonary Motion , 2005, 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference.

[34]  R M Gardner,et al.  Optimizing the electrocardiogram and pressure monitoring , 1986, Critical care medicine.

[35]  O. Boric-Lubecke,et al.  A digital signal processor for Doppler radar sensing of vital signs , 2001, 2001 Conference Proceedings of the 23rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[36]  Jenshan Lin,et al.  Fast Acquisition of Heart Rate in Noncontact Vital Sign Radar Measurement Using Time-Window-Variation Technique , 2016, IEEE Transactions on Instrumentation and Measurement.

[37]  F Camarasa Piquer,et al.  [Sudden infant death syndrome]. , 1999, Anales espanoles de pediatria.

[38]  Young-Jin Park,et al.  Robust heart rate detection method using UWB impulse radar , 2016, 2016 International Conference on Information and Communication Technology Convergence (ICTC).

[39]  J. H. Shin,et al.  Automatic ballistocardiogram (BCG) beat detection using a template matching approach , 2008, 2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[40]  Hirofumi Taki,et al.  Feature-Based Correlation and Topological Similarity for Interbeat Interval Estimation Using Ultrawideband Radar , 2016, IEEE Transactions on Biomedical Engineering.