Multichannel oscillatory-flow multiplex PCR microfluidics for high-throughput and fast detection of foodborne bacterial pathogens

In the field of continuous-flow PCR, the amplification throughput in a single reaction solution is low and the single-plex PCR is often used. In this work, we reported a flow-based multiplex PCR microfluidic system capable of performing high-throughput and fast DNA amplification for detection of foodborne bacterial pathogens. As a demonstration, the mixture of DNA targets associated with three different foodborne pathogens was included in a single PCR solution. Then, the solution flowed through microchannels incorporated onto three temperature zones in an oscillatory manner. The effect factors of this oscillatory-flow multiplex PCR thermocycling have been demonstrated, including effects of polymerase concentration, cycling times, number of cycles, and DNA template concentration. The experimental results have shown that the oscillatory-flow multiplex PCR, with a volume of only 5 μl, could be completed in about 13 min after 35 cycles (25 cycles) at 100 μl/min (70 μl/min), which is about one-sixth of the time required on the conventional machine (70 min). By using the presently designed DNA sample model, the minimum target concentration that could be detected at 30 μl/min was 9.8 × 10−2 ng/μl (278-bp, S. enterica), 11.2 × 10−2 ng/μl (168-bp, E. coli O157: H7), and 2.88 × 10−2 ng/μl (106-bp, L. monocytogenes), which corresponds to approximately 3.72 × 104 copies/μl, 3.58 × 104 copies/μl, and 1.79 × 104 copies/μl, respectively. This level of speed and sensitivity is comparable to that achievable in most other continuous-flow PCR systems. In addition, the four individual channels were used to achieve multi-target PCR analysis of three different DNA samples from different food sources in parallel, thereby achieving another level of multiplexing.

[1]  A Manz,et al.  Miniaturised nucleic acid analysis. , 2004, Lab on a chip.

[2]  Steffen Hardt,et al.  Automated chip-based device for simple and fast nucleic acid amplification , 2005, Expert review of molecular diagnostics.

[3]  Ji-Yen Cheng,et al.  Performing microchannel temperature cycling reactions using reciprocating reagent shuttling along a radial temperature gradient. , 2005, The Analyst.

[4]  J. Köhler,et al.  Miniaturized flow-through PCR with different template types in a silicon chip thermocycler. , 2001, Lab on a chip.

[5]  Pei-Jer Chen,et al.  A micro circulating PCR chip using a suction-type membrane for fluidic transport , 2009, Biomedical microdevices.

[6]  Chunsun Zhang,et al.  PCR microfluidic devices for DNA amplification. , 2006, Biotechnology advances.

[7]  H. Steiner,et al.  Long target droplet polymerase chain reaction with a microfluidic device for high-throughput detection of pathogenic bacteria at clinical sensitivity , 2011, Biomedical microdevices.

[8]  T. G. Mitchell,et al.  Multiplexed real-time polymerase chain reaction on a digital microfluidic platform. , 2010, Analytical chemistry.

[9]  Jong-Hyun Lee,et al.  Fabrications of a continuous-flow DNA amplifier using dry film resist , 2010 .

[10]  Collin Tranter,et al.  Glass-composite prototyping for flow PCR with in situ DNA analysis , 2010, Biomedical microdevices.

[11]  J. Köhler,et al.  Application of an asymmetric helical tube reactor for fast identification of gene transcripts of pathogenic viruses by micro flow-through PCR , 2009, Biomedical microdevices.

[12]  James S. Wilkinson,et al.  Design and theoretical evaluation of a novel microfluidic device to be used for PCR , 2003 .

[13]  Nam-Trung Nguyen,et al.  High-throughput polymerase chain reaction in parallel circular loops using magnetic actuation. , 2008, Analytical chemistry.

[14]  Da Xing,et al.  Miniaturized PCR chips for nucleic acid amplification and analysis: latest advances and future trends , 2007, Nucleic acids research.

[15]  Amplification of SPPS150 and Salmonella typhi DNA with a high throughput oscillating flow polymerase chain reaction device. , 2010, Biomicrofluidics.

[16]  Andreas Manz,et al.  Total nucleic acid analysis integrated on microfluidic devices. , 2007, Lab on a chip.

[17]  A Manz,et al.  Chemical amplification: continuous-flow PCR on a chip. , 1998, Science.

[18]  Andreas Hierlemann,et al.  Autonomous microfluidic multi-channel chip for real-time PCR with integrated liquid handling , 2007, Biomedical microdevices.

[19]  Tetsuo Ohashi,et al.  A simple device using magnetic transportation for droplet-based PCR , 2007, Biomedical microdevices.

[20]  Guoqing Hu,et al.  Electrokinetically controlled real-time polymerase chain reaction in microchannel using Joule heating effect , 2006 .

[21]  D. Ehrlich,et al.  A closed-cycle capillary polymerase chain reaction machine. , 2001, Analytical chemistry.

[22]  Andreas Manz,et al.  Ultrasensitive PCR and real-time detection from human genomic samples using a bidirectional flow microreactor. , 2007, Analytical chemistry.

[23]  Zhixin Li,et al.  Droplet-based micro oscillating-flow PCR chip , 2005 .

[24]  H. John Crabtree,et al.  Microfabricated device for DNA and RNA amplification by continuous-flow polymerase chain reaction and reverse transcription-polymerase chain reaction with cycle number selection. , 2003, Analytical chemistry.

[25]  N. Heerema,et al.  Multiplex PCR: critical parameters and step-by-step protocol. , 1997, BioTechniques.

[26]  Da Xing,et al.  Microfluidic gradient PCR (MG-PCR): a new method for microfluidic DNA amplification , 2010, Biomedical microdevices.

[27]  Vijay Srinivasan,et al.  Development of a digital microfluidic platform for point of care testing. , 2008, Lab on a chip.

[28]  Roberto Cingolani,et al.  Rapid nested-PCR for tyrosinase gene detection on chip. , 2011, Biosensors & bioelectronics.

[29]  Roberto Cingolani,et al.  Reduction of water evaporation in polymerase chain reaction microfluidic devices based on oscillating-flow. , 2010, Biomicrofluidics.

[30]  D. Ehrlich,et al.  Thirty-cycle temperature optimization of a closed-cycle capillary PCR machine. , 2002, BioTechniques.