Noise aliasing and the 3D NEQ of flat-panel cone-beam CT: effect of 2D/3D apertures and sampling.

The ability to tune an imaging system to be optimal for a specific task is an essential component of image quality. This article discusses the ability to tune the noise-equivalent quanta (NEQ) of cone-beam computed tomography (CBCT) by managing noise aliasing through binning of data at different points in the reconstruction cascade. The noise power spectrum, modulation transfer function, and NEQ for CBCT are calculated using cascaded systems analysis. Binning is treated as a modular process, insertable between any two stages (in both the 2D projection domain and in the 3D reconstruction domain), consisting of the application of an aperture, followed by the resampling of data (which introduces noise aliasing). Several conditions were examined to demonstrate the validity of the model and to describe the effect on the image quality of some common reconstruction and visualization techniques. It was found that when downsampling data for increased reconstruction speed, binning in 2D results in a superior low-frequency NEQ, while binning in 3D results in a superior high-frequency NEQ. Furthermore, visualization procedures such as slice averaging were found not to degrade the NEQ provided the sampling interval is unchanged. Finally methods for reducing noise aliasing by oversampling are examined, and a method to eliminate noise aliasing without increasing reconstruction time is proposed. These results demonstrate the ease with which the NEQ of CBCT can be modified and thus optimized for specific tasks and show how such analysis can be used to improve image quality.

[1]  Kunio Doi,et al.  A simple method for determining the modulation transfer function in digital radiography , 1992, IEEE Trans. Medical Imaging.

[2]  Andrew D. A. Maidment,et al.  Linear response theory for detectors consisting of discrete arrays. , 2000, Medical physics.

[3]  J Yorkston,et al.  Empirical and theoretical investigation of the noise performance of indirect detection, active matrix flat-panel imagers (AMFPIs) for diagnostic radiology. , 1997, Medical physics.

[4]  J H Siewerdsen,et al.  Optimization of dual-energy imaging systems using generalized NEQ and imaging task. , 2006, Medical physics.

[5]  Jeffrey H. Siewerdsen,et al.  Three-dimensional NEQ transfer characteristics of volume CT using direct- and indirect-detection flat-panel imagers , 2003, SPIE Medical Imaging.

[6]  L. Feldkamp,et al.  Practical cone-beam algorithm , 1984 .

[7]  M F Kijewski,et al.  The noise power spectrum of CT images. , 1987, Physics in medicine and biology.

[8]  Jeffrey H Siewerdsen,et al.  Cascaded systems analysis of the 3D noise transfer characteristics of flat-panel cone-beam CT. , 2008, Medical physics.

[9]  A Fenster,et al.  A spatial-frequency dependent quantum accounting diagram and detective quantum efficiency model of signal and noise propagation in cascaded imaging systems. , 1994, Medical physics.

[10]  Kai Yang,et al.  Noise power properties of a cone-beam CT system for breast cancer detection. , 2008, Medical physics.

[11]  D. Jaffray,et al.  A framework for noise-power spectrum analysis of multidimensional images. , 2002, Medical physics.

[12]  M. Rabbani,et al.  Detective quantum efficiency of imaging systems with amplifying and scattering mechanisms. , 1987, Journal of the Optical Society of America. A, Optics and image science.

[13]  I A Cunningham,et al.  Parallel cascades: new ways to describe noise transfer in medical imaging systems. , 2001, Medical physics.

[14]  Stephen Rudin,et al.  Micro-angiography for neuro-vascular imaging. II. Cascade model analysis. , 2003, Medical physics.

[15]  J H Siewerdsen,et al.  Generalized DQE analysis of radiographic and dual-energy imaging using flat-panel detectors. , 2005, Medical physics.

[16]  Jeffrey H. Siewerdsen,et al.  Cone-beam CT with a flat-panel imager: noise considerations for fully 3D computed tomography , 2000, Medical Imaging.

[17]  Wei Zhao,et al.  Three-dimensional linear system analysis for breast tomosynthesis. , 2008, Medical physics.

[18]  John M Boone,et al.  Characterizing anatomical variability in breast CT images. , 2008, Medical physics.

[19]  S Suryanarayanan,et al.  Full breast digital mammography with an amorphous silicon-based flat panel detector: physical characteristics of a clinical prototype. , 2000, Medical physics.

[20]  J Yorkston,et al.  Signal, noise power spectrum, and detective quantum efficiency of indirect-detection flat-panel imagers for diagnostic radiology. , 1998, Medical physics.

[21]  J H Siewerdsen,et al.  Intraoperative cone-beam CT for guidance of head and neck surgery: Assessment of dose and image quality using a C-arm prototype. , 2006, Medical physics.

[22]  J A Rowlands,et al.  Effects of characteristic x rays on the noise power spectra and detective quantum efficiency of photoconductive x-ray detectors. , 2001, Medical physics.

[23]  K. Hanson,et al.  Detectability in computed tomographic images. , 1979, Medical physics.

[24]  Srinivasan Vedantham,et al.  Solid-state fluoroscopic imager for high-resolution angiography: parallel-cascaded linear systems analysis. , 2004, Medical physics.

[25]  J. Wong,et al.  Characterization of a fluoroscopic imaging system for kV and MV radiography. , 2000, Medical physics.

[26]  P. Munro,et al.  A quantum accounting and detective quantum efficiency analysis for video-based portal imaging. , 1997, Medical physics.

[27]  Rebecca Fahrig,et al.  Cascaded systems analysis of the 3D NEQ for cone-beam CT and tomosynthesis , 2008, SPIE Medical Imaging.

[28]  J A Rowlands,et al.  Digital radiology using active matrix readout of amorphous selenium: theoretical analysis of detective quantum efficiency. , 1997, Medical physics.

[29]  B. Fallone,et al.  Detective quantum efficiency of a direct-detection active matrix flat panel imager at megavoltage energies. , 2001, Medical physics.

[30]  Jeffrey H. Siewerdsen,et al.  Unified iso-SNR approach to task-directed imaging in flat-panel cone-beam CT , 2002, SPIE Medical Imaging.

[31]  J H Siewerdsen,et al.  Spektr: a computational tool for x-ray spectral analysis and imaging system optimization. , 2004, Medical physics.

[32]  Norbert J. Pelc,et al.  Analytical construction of 3D NPS for a cone beam CT system , 2009, Medical Imaging.

[33]  Jeffrey H. Siewerdsen,et al.  Analysis of image noise in 3D cone-beam CT: spatial and Fourier domain approaches under conditions of varying stationarity , 2008, SPIE Medical Imaging.

[34]  I A Cunningham,et al.  Optimal phosphor thickness for portal imaging. , 1997, Medical physics.

[35]  Jeffrey H. Siewerdsen,et al.  Incorporation of task in 3D imaging performance evaluation: the impact of asymmetric NPS on detectability , 2004, SPIE Medical Imaging.