Highly sensitive polymer-based cantilever-sensors for DNA detection.

We present a technology for the fabrication of cantilever arrays aimed to develop an integrated biosensor microsystem. The fabrication process is based on spin coating of the photosensitive polymer and near-ultraviolet exposure. Arrays of up to 33 microcantilevers are fabricated in the novel polymer material SU-8. The low Young's modulus of the polymer, 40 times lower than that of silicon, enables to improve the sensitivity of the sensor device for target detection. The mechanical properties of SU-8 cantilevers, such as spring constant, resonant frequency and quality factor are characterized as a function of the dimensions and the medium. The devices have been tested for measurement of the adsorption of single stranded DNA and subsequent interstitial adsorption of lateral spacer molecules. We demonstrate that sensitivity is enhanced by a factor of six compared to that of commercial silicon nitride cantilevers.

[1]  John E. Sader,et al.  Surface stress induced deflections of cantilever plates with applications to the atomic force microscope: Rectangular plates , 2001 .

[2]  H. Rothuizen,et al.  Translating biomolecular recognition into nanomechanics. , 2000, Science.

[3]  Peter Vettiger,et al.  High-aspect-ratio, ultrathick, negative-tone near-UV photoresist and its applications for MEMS , 1998 .

[4]  E. Hall,et al.  The nature of biotechnology. , 1988, Journal of biomedical engineering.

[5]  M. Miles,et al.  Chemical sensors and biosensors in liquid environment based on microcantilevers with amplified quality factor. , 2001, Ultramicroscopy.

[6]  N. D. Rooij,et al.  Soft, entirely photoplastic probes for scanning force microscopy , 1999 .

[7]  David Bull,et al.  Proceedings of SPIE - The International Society for Optical Engineering , 2007 .

[8]  M. Grattarola,et al.  Micromechanical cantilever-based biosensors , 2001 .

[9]  Cagri A. Savran,et al.  Microfabricated mechanical biosensor with inherently differential readout , 2003 .

[10]  H. Lang,et al.  Multiple label-free biodetection and quantitative DNA-binding assays on a nanomechanical cantilever array , 2002, Proceedings of the National Academy of Sciences of the United States of America.

[11]  J Thaysen,et al.  Optimised cantilever biosensor with piezoresistive read-out. , 2003, Ultramicroscopy.

[12]  Daniel Bertrand,et al.  Buried microchannels in photopolymer for delivering of solutions to neurons in a network , 1998 .

[13]  T. Thundat,et al.  Bioassay of prostate-specific antigen (PSA) using microcantilevers , 2001, Nature Biotechnology.

[14]  M. Despont,et al.  SU-8: a low-cost negative resist for MEMS , 1997 .

[15]  L. Lechuga,et al.  Development of nanomechanical biosensors for detection of the pesticide DDT. , 2003, Biosensors & bioelectronics.

[16]  Laura M. Lechuga,et al.  Nanomechanics for specific biological detection , 2003, SPIE Microtechnologies.

[17]  Xiangqin Cui,et al.  Sensors and Actuators B , 2003 .

[18]  Javier Tamayo,et al.  Piconewton regime dynamic force microscopy in liquid , 2000 .

[19]  R. Feng,et al.  Influence of processing conditions on the thermal and mechanical properties of SU8 negative photoresist coatings , 2002 .