Design and Analysis of Experimental Device for Fatigue Test of the Lower Limb Vascular Stent *

Vascular stenting is a minimally invasive procedure to treat vascular occlusion and the physicochemical properties of the stent, like fatigue, determine its service life, which is important to patients’ health. However, the current stent fatigue testing equipment cannot simulate the actual deformation of the stent in human body. Therefore, the development of a better stent fatigue testing device is of great significance. In order to simulate the physical environments of the stent due to the movements of lower extremity, the gait analysis is performed and an experimental device for fatigue testing is designed using spherical linkage mechanism and planar linkage mechanism. In this paper, the femur in the lower extremity is fixed as a frame, and the gait data of normal walking state is transformed to obtain the movement data of pelvis and tibia relative to femur. In addition, the motion of the spherical linkage and the fitting method of its space trajectory are analyzed in detail.

[1]  Jwu-Sheng Hu,et al.  The effects of gait training using powered lower limb exoskeleton robot on individuals with complete spinal cord injury , 2018, Journal of NeuroEngineering and Rehabilitation.

[2]  Giancarlo Pennati,et al.  Fatigue behaviour of Nitinol peripheral stents: the role of plaque shape studied with computational structural analyses. , 2014, Medical engineering & physics.

[3]  Jinkui Chu,et al.  Numerical atlas method for path generation of spherical four-bar mechanism , 2010 .

[4]  Sanjay Shrivastava,et al.  Fracture of self-expanding nitinol stents stressed in vitro under simulated intravascular conditions. , 2008, Journal of vascular surgery.

[5]  Kyoungchul Kong,et al.  Active Impedance Control of a lower limb exoskeleton to assist sit-to-stand movement , 2016, 2016 IEEE International Conference on Robotics and Automation (ICRA).

[6]  Giancarlo Pennati,et al.  Computational Modelling of In Vitro Set-Ups for Peripheral Self-Expanding Nitinol Stents: The Importance of Stent–Wall Interaction in the Assessment of the Fatigue Resistance , 2013 .

[7]  Phillip J. McKerrow,et al.  Introduction to robotics , 1991 .

[8]  John J. Craig Zhu,et al.  Introduction to robotics mechanics and control , 1991 .

[9]  Shijia Zhao,et al.  Performance of self-expanding nitinol stent in a curved artery: impact of stent length and deployment orientation. , 2012, Journal of biomechanical engineering.

[10]  R. Guidoin,et al.  Stent fabric fatigue of grafts supported by Z-stents versus ringed stents: An in vitro buckling test , 2014, Journal of biomaterials applications.