3D PET list-mode iterative reconstruction using time-of-flight information

A limited number of time-of-flight (TOF) PET systems were developed and studied in the 1980*s and early 1990's using fast scintillators such as BaF2 or CsF. These systems had the very good timing resolution needed for TOF PET but the lower stopping power and low light output yield of these scintillators could not provide systems with comparable performance to BOO. Recent development of other fast scintillators including LSO and LaBr3 has recently renewed interest in TOF PET. All of the TOF PET developed in the 80's and 90's used axial collimation with a very small axial FOV. Most TOF reconstruction methods that were studied were 2D. In this study, a 3D EM-ML list-mode iterative algorithm using TOF information has been implemented and tested using a new Monte Carlo simulation package, GATE, providing time information related to each photon travel from its annihilation to detection point and list-mode format output. Visually, it appears as if TOF information can improve detectability in reconstructed images.

[1]  Victor J. Sank,et al.  POTENTIAL ADVANTAGES OF A CESIUM FLUORIDE SCINTILLATOR FOR A TIME‐OF‐FLIGHT POSITRON CAMERA , 1980, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[2]  Nizar A. Mullani,et al.  System Design of Fast Pet Scanners Utilizing Time-of-Flight , 1981, IEEE Transactions on Nuclear Science.

[3]  L. Shepp,et al.  Maximum Likelihood Reconstruction for Emission Tomography , 1983, IEEE Transactions on Medical Imaging.

[4]  R. Siddon Fast calculation of the exact radiological path for a three-dimensional CT array. , 1985, Medical physics.

[5]  K. Erlandsson,et al.  Fast accurate iterative reconstruction for low-statistics positron volume imaging. , 1998, Physics in medicine and biology.

[6]  Lucas C. Parra,et al.  List-Mode Likelihood EM Algorithm and Noise Estimation Demonstrated on 2D-PET , 1998, IEEE Trans. Medical Imaging.

[7]  W. Moses,et al.  Prospects for time-of-flight PET using LSO scintillator , 1999 .

[8]  A. Nemirovski,et al.  The design and implementation of COSEN, an iterative algorithm for fully 3-D listmode data , 2001, IEEE Transactions on Medical Imaging.

[9]  Michael Zibulevsky,et al.  The Design and Implementation of COSEM, an Iterative Algorithm for Fully 3D Listmode Data , 2001, IEEE Trans. Medical Imaging.

[10]  G. Muehllehner,et al.  Investigation of lanthanum scintillators for 3-D PET , 2002 .

[11]  S. Surti,et al.  Investigation of lanthanum scintillators for 3D PET , 2002, 2002 IEEE Nuclear Science Symposium Conference Record.

[12]  W. Moses Time of flight in PET revisited , 2003 .