Direct force balance method for atomic force microscopy lateral force calibration

A new and simple calibration method for atomic force microscopy (AFM) is developed. This nonscanning method is based on direct force balances on surfaces with known slopes. The lateral force calibration is performed during force-distance measurements for normal force calibration. This method requires a substrate with known slopes, the z motion of the piezocalibrated, and the normal spring constant known. This technique determines not only the lateral detector sensitivity (N/V) but also the detector offset (V/m) and off-centering angle (α) for asymmetric cantilever-tip geometries. Because it is nonscanning, the AFM cantilever can be calibrated without dulling the tip.

[1]  B. Bhushan,et al.  Atomic-Scale Friction Measurements Using Friction Force Microscopy. Part 1. General Principles and New Measurement Techniques , 1994 .

[2]  K. J. Gabriel,et al.  In situ friction and wear measurements in integrated polysilicon mechanisms , 1990 .

[3]  K. Strawhecker,et al.  Reduction of adhesion and friction of silicon oxide surface in the presence of n-propanol vapor in the gas phase , 2005 .

[4]  Izhak Etsion,et al.  An improved wedge calibration method for lateral force in atomic force microscopy , 2003 .

[5]  Izhak Etsion,et al.  A Semi-Analytical Solution for the Sliding Inception of a Spherical Contact , 2003 .

[6]  B. Kraus,et al.  Quantitative characterization of friction coefficient using lateral force microscope in the wearless regime , 2004 .

[7]  Robert W. Carpick,et al.  Calibration of frictional forces in atomic force microscopy , 1996 .

[8]  John E. Sader,et al.  Normal and torsional spring constants of atomic force microscope cantilevers , 2004 .

[9]  J. Parlebas,et al.  Growth, electronic, magnetic and spectroscopic properties of transition metals on graphite , 1999 .

[10]  C. Mate,et al.  Influence of capillary condensation of water on nanotribology studied by force microscopy , 1994 .

[11]  Simon Biggs,et al.  Quantitative comparison of three calibration techniques for the lateral force microscope , 2001 .

[12]  Rutland,et al.  Tip friction - torsional spring constant determination. , 2000, Colloids and surfaces. B, Biointerfaces.

[13]  B. Bhushan,et al.  Tribological studies of silicon for magnetic recording applications (invited) , 1993 .

[14]  J. Sader,et al.  Calibration of rectangular atomic force microscope cantilevers , 1999 .

[15]  P. Hansma,et al.  A nondestructive method for determining the spring constant of cantilevers for scanning force microscopy , 1993 .

[16]  J. Sader Frequency response of cantilever beams immersed in viscous fluids with applications to the atomic force microscope , 1998 .