A VISUAL GUIDE FOR LOWER LIMB PROTHETIC ALIGNMENT

A novel method to provide an objective visual guide during lower limb prosthetic alignment is proposed. A customized ambulatory device was built to collect kinematic and temporal gait data from 3 subjects walking in four different experiment setups. Multiple gait events within a gait cycle and stride time were derived as feature variables and were pre-processed using Principle Component Analysis (PCA). Distinctive clusters due to different walking setups were noticed in a PCA plot in two dimensions. Dispersion of each clusters and distances amongst each other explains the walking variability and differences under different setups.

[1]  S Blumentritt A new biomechanical method for determination of static prosthetic alignment , 1997, Prosthetics and orthotics international.

[2]  I.P.I. Pappas,et al.  A reliable, gyroscope based gait phase detection sensor embedded in a shoe insole , 2002, Proceedings of IEEE Sensors.

[3]  J. Allum,et al.  Gait event detection using linear accelerometers or angular velocity transducers in able-bodied and spinal-cord injured individuals. , 2006, Gait & posture.

[4]  T Chau,et al.  A review of analytical techniques for gait data. Part 2: neural network and wavelet methods. , 2001, Gait & posture.

[5]  A H Hansen,et al.  Prosthetic foot rollover shapes with implications for alignment of transtibial prostheses , 2000, Prosthetics and orthotics international.

[6]  Kamiar Aminian,et al.  Spatio-temporal parameters of gait measured by an ambulatory system using miniature gyroscopes. , 2002, Journal of biomechanics.

[7]  T. Schmalz,et al.  Energy expenditure and biomechanical characteristics of lower limb amputee gait: the influence of prosthetic alignment and different prosthetic components. , 2002, Gait & posture.

[8]  Jan Rueterbories,et al.  Methods for gait event detection and analysis in ambulatory systems. , 2010, Medical engineering & physics.

[9]  M H Granat,et al.  A practical gait analysis system using gyroscopes. , 1999, Medical engineering & physics.

[10]  A H Hansen,et al.  Alignment of transtibial prostheses based on rollover shape principles , 2003, Prosthetics and orthotics international.

[11]  J. Cheng,et al.  Significance of non-level walking on transtibial prosthesis fitting with particular reference to the effects of anterior-posterior alignment. , 2001, Journal of rehabilitation research and development.

[12]  S. Blumentrttt,et al.  Effects of sagittal plane prosthetic alignment on standing trans-tibial amputee knee loads , 1999, Prosthetics and orthotics international.

[13]  Morrison Jb,et al.  Prostheses alignment: effect on gait of persons with below-knee amputations. , 1984 .

[14]  B. Auvinet,et al.  Reference data for normal subjects obtained with an accelerometric device. , 2002, Gait & posture.

[15]  A. E. Chapman,et al.  Prostheses alignment: effect on gait of persons with below-knee amputations. , 1984, Archives of physical medicine and rehabilitation.

[16]  J. Geertzen,et al.  Skin problems in lower limb amputees: an overview by case reports , 2007, Journal of the European Academy of Dermatology and Venereology : JEADV.

[17]  J Mizrahi,et al.  Influence of prosthesis alignment on the standing balance of below-knee amputees. , 1994, Clinical biomechanics.

[18]  Hylton B Menz,et al.  Accelerometry: a technique for quantifying movement patterns during walking. , 2008, Gait & posture.

[19]  J. P. Paul,et al.  Alignment of lower-limb prostheses. , 1986, Journal of rehabilitation research and development.

[20]  C W Radcliffe Four-bar linkage prosthetic knee mechanisms: Kinematics, alignment and prescription criteria , 1994, Prosthetics and orthotics international.