Slice-wise reconstruction for low-dose cone-beam CT using a deep residual convolutional neural network

Because of the growing concern over the radiation dose delivered to patients, X-ray cone-beam CT (CBCT) imaging of low dose is of great interest. It is difficult for traditional reconstruction methods such as Feldkamp to reduce noise and keep resolution at low doses. A typical method to solve this problem is using optimization-based methods with careful modeling of physics and additional constraints. However, it is computationally expensive and very time-consuming to reach an optimal solution. Recently, some pioneering work applying deep neural networks had some success in characterizing and removing artifacts from a low-dose data set. In this study, we incorporate imaging physics for a cone-beam CT into a residual convolutional neural network and propose a new end-to-end deep learning-based method for slice-wise reconstruction. By transferring 3D projection to a 2D problem with a noise reduction property, we can not only obtain reconstructions of high image quality, but also lower the computational complexity. The proposed network is composed of three serially connected sub-networks: a cone-to-fan transformation sub-network, a 2D analytical inversion sub-network, and an image refinement sub-network. This provides a comprehensive solution for end-to-end reconstruction for CBCT. The advantages of our method are that the network can simplify a 3D reconstruction problem to a 2D slice-wise reconstruction problem and can complete reconstruction in an end-to-end manner with the system matrix integrated into the network design. Furthermore, reconstruction can be less computationally expensive and easily parallelizable compared with iterative reconstruction methods.

[1]  Steve B. Jiang,et al.  GPU-based Fast Low Dose Cone Beam CT Reconstruction via Total Variation , 2010, 1001.0599.

[2]  E. Sidky,et al.  Image reconstruction in circular cone-beam computed tomography by constrained, total-variation minimization , 2008, Physics in medicine and biology.

[3]  Xuanqin Mou,et al.  Low-Dose CT Image Denoising Using a Generative Adversarial Network With Wasserstein Distance and Perceptual Loss , 2017, IEEE Transactions on Medical Imaging.

[4]  D. Parker Optimal short scan convolution reconstruction for fan beam CT , 1982 .

[5]  Alvin C. Silva,et al.  Innovations in CT dose reduction strategy: application of the adaptive statistical iterative reconstruction algorithm. , 2010, AJR. American journal of roentgenology.

[6]  Jie Tang,et al.  Prior image constrained compressed sensing: implementation and performance evaluation. , 2011, Medical physics.

[7]  Jin Liu,et al.  Discriminative Feature Representation to Improve Projection Data Inconsistency for Low Dose CT Imaging , 2017, IEEE Transactions on Medical Imaging.

[8]  Hengyong Yu,et al.  Convolutional Neural Network Based Metal Artifact Reduction in X-Ray Computed Tomography , 2017, IEEE Transactions on Medical Imaging.

[9]  Li Liang,et al.  A practical image reconstruction and processing method for symmetrically off-center detector CBCT system , 2013 .

[10]  Jong Chul Ye,et al.  Framing U-Net via Deep Convolutional Framelets: Application to Sparse-View CT , 2017, IEEE Transactions on Medical Imaging.

[11]  Huazhong Shu,et al.  Artifact Suppressed Dictionary Learning for Low-Dose CT Image Processing , 2014, IEEE Transactions on Medical Imaging.

[12]  Jing Wang,et al.  Statistical image reconstruction for low-dose CT using nonlocal means-based regularization , 2014, Comput. Medical Imaging Graph..

[13]  Jeffrey A. Fessler,et al.  Statistical image reconstruction for polyenergetic X-ray computed tomography , 2002, IEEE Transactions on Medical Imaging.

[14]  Jong Chul Ye,et al.  A deep convolutional neural network using directional wavelets for low‐dose X‐ray CT reconstruction , 2016, Medical physics.

[15]  Jin Liu,et al.  3D Feature Constrained Reconstruction for Low-Dose CT Imaging , 2018, IEEE Transactions on Circuits and Systems for Video Technology.

[16]  K. Ozasa Epidemiological research on radiation-induced cancer in atomic bomb survivors , 2016, Journal of radiation research.

[17]  Yuxiang Xing,et al.  A free-geometry cone beam CT and its FDK-type reconstruction , 2007 .

[18]  Subhransu Maji,et al.  Bilinear CNN Models for Fine-Grained Visual Recognition , 2015, 2015 IEEE International Conference on Computer Vision (ICCV).

[19]  Thomas Brox,et al.  U-Net: Convolutional Networks for Biomedical Image Segmentation , 2015, MICCAI.

[20]  Geoffrey E. Hinton,et al.  Deep Learning , 2015, Nature.

[21]  Hu Chen,et al.  LEARN: Learned Experts’ Assessment-Based Reconstruction Network for Sparse-Data CT , 2017, IEEE Transactions on Medical Imaging.

[22]  Hu Chen,et al.  Low-dose CT via convolutional neural network. , 2017, Biomedical optics express.

[23]  Lucia J. M. Kroft,et al.  Scan time and patient dose for thoracic imaging in neonates and small children using axial volumetric 320-detector row CT compared to helical 64-, 32-, and 16- detector row CT acquisitions , 2009, Pediatric Radiology.

[24]  Ke Li,et al.  Statistical model based iterative reconstruction (MBIR) in clinical CT systems: experimental assessment of noise performance. , 2014, Medical physics.

[25]  David Hughes,et al.  Deep Learning for Image-Based Cassava Disease Detection , 2017, Front. Plant Sci..

[26]  Feng Lin,et al.  Low-Dose CT With a Residual Encoder-Decoder Convolutional Neural Network , 2017, IEEE Transactions on Medical Imaging.

[27]  Sheila Weinmann,et al.  The use of computed tomography in pediatrics and the associated radiation exposure and estimated cancer risk. , 2013, JAMA pediatrics.

[28]  Mannudeep K. Kalra,et al.  Low-Dose CT with a Residual Encoder-Decoder Convolutional Neural Network (RED-CNN) , 2017, ArXiv.

[29]  Jie Tang,et al.  Prior image constrained compressed sensing (PICCS): a method to accurately reconstruct dynamic CT images from highly undersampled projection data sets. , 2008, Medical physics.

[30]  Alvin C. Silva,et al.  Iterative Reconstruction Technique for Reducing Body Radiation Dose at Ct: Feasibility Study Hara Et Al. Ct Iterative Reconstruction Technique Gastrointestinal Imaging Original Research , 2022 .