MRI-Based Nonrigid Motion Correction in Simultaneous PET/MRI

Respiratory and cardiac motion is the most serious limitation to whole-body PET, resulting in spatial resolution close to 1 cm. Furthermore, motion-induced inconsistencies in the attenuation measurements often lead to significant artifacts in the reconstructed images. Gating can remove motion artifacts at the cost of increased noise. This paper presents an approach to respiratory motion correction using simultaneous PET/MRI to demonstrate initial results in phantoms, rabbits, and nonhuman primates and discusses the prospects for clinical application. Methods: Studies with a deformable phantom, a free-breathing primate, and rabbits implanted with radioactive beads were performed with simultaneous PET/MRI. Motion fields were estimated from concurrently acquired tagged MR images using 2 B-spline nonrigid image registration methods and incorporated into a PET list-mode ordered-subsets expectation maximization algorithm. Using the measured motion fields to transform both the emission data and the attenuation data, we could use all the coincidence data to reconstruct any phase of the respiratory cycle. We compared the resulting SNR and the channelized Hotelling observer (CHO) detection signal-to-noise ratio (SNR) in the motion-corrected reconstruction with the results obtained from standard gating and uncorrected studies. Results: Motion correction virtually eliminated motion blur without reducing SNR, yielding images with SNR comparable to those obtained by gating with 5–8 times longer acquisitions in all studies. The CHO study in dynamic phantoms demonstrated a significant improvement (166%–276%) in lesion detection SNR with MRI-based motion correction as compared with gating (P < 0.001). This improvement was 43%–92% for large motion compared with lesion detection without motion correction (P < 0.001). CHO SNR in the rabbit studies confirmed these results. Conclusion: Tagged MRI motion correction in simultaneous PET/MRI significantly improves lesion detection compared with respiratory gating and no motion correction while reducing radiation dose. In vivo primate and rabbit studies confirmed the improvement in PET image quality and provide the rationale for evaluation in simultaneous whole-body PET/MRI clinical studies.

[1]  Ronald H. Huesman,et al.  List mode reconstruction for PET with motion compensation: a simulation study , 2002, Proceedings IEEE International Symposium on Biomedical Imaging.

[2]  O. Schober,et al.  List Mode–Driven Cardiac and Respiratory Gating in PET , 2009, Journal of Nuclear Medicine.

[3]  Matt A. King,et al.  Channelized hotelling and human observer correlation for lesion detection in hepatic SPECT imaging. , 2000, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[4]  A J Reader,et al.  List-mode-based reconstruction for respiratory motion correction in PET using non-rigid body transformations , 2007, Physics in medicine and biology.

[5]  Jeffrey A. Fessler,et al.  A Simple Regularizer for B-spline Nonrigid Image Registration That Encourages Local Invertibility , 2009, IEEE Journal of Selected Topics in Signal Processing.

[6]  Tobias Schaeffter,et al.  Simultaneous PET–MR acquisition and MR-derived motion fields for correction of non-rigid motion in PET , 2010, Annals of nuclear medicine.

[7]  Robin M Heidemann,et al.  Generalized autocalibrating partially parallel acquisitions (GRAPPA) , 2002, Magnetic resonance in medicine.

[8]  Jerry L. Prince,et al.  Motion estimation from tagged MR image sequences , 1992, IEEE Trans. Medical Imaging.

[9]  P. Boesiger,et al.  SENSE: Sensitivity encoding for fast MRI , 1999, Magnetic resonance in medicine.

[10]  Kris Thielemans,et al.  Correction of head movement on PET studies: comparison of methods. , 2006, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[11]  Ravindra Manjeshwar,et al.  Theoretical Comparison of Motion Correction Techniques for PET Image Reconstruction , 2006, 2006 IEEE Nuclear Science Symposium Conference Record.

[12]  Nassir Navab,et al.  Joint Reconstruction of Image and Motion in Gated Positron Emission Tomography , 2010, IEEE Transactions on Medical Imaging.

[13]  Michael Brady,et al.  Regularized B-spline deformable registration for respiratory motion correction in PET images , 2008, 2008 IEEE Nuclear Science Symposium Conference Record.

[14]  Steven G. Ross,et al.  Application and Evaluation of a Measured Spatially Variant System Model for PET Image Reconstruction , 2010, IEEE Transactions on Medical Imaging.

[15]  Jerry L. Prince,et al.  Regenerating MR tagged images using harmonic phase (HARP) methods , 2004, IEEE Transactions on Biomedical Engineering.

[16]  G El Fakhri,et al.  Nonrigid PET motion compensation in the lower abdomen using simultaneous tagged-MRI and PET imaging. , 2011, Medical physics.

[17]  C. Ling,et al.  Effect of respiratory gating on quantifying PET images of lung cancer. , 2002, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[18]  Nassir Navab,et al.  Dual cardiac–respiratory gated PET: implementation and results from a feasibility study , 2007, European Journal of Nuclear Medicine and Molecular Imaging.

[19]  L. Axel,et al.  MR imaging of motion with spatial modulation of magnetization. , 1989, Radiology.

[20]  Gerald Antoch,et al.  Combined PET/MRI: a new dimension in whole-body oncology imaging? , 2009, European Journal of Nuclear Medicine and Molecular Imaging.

[21]  C. Claussen,et al.  Simultaneous Mr/pet Imaging of the Human Brain: Feasibility Study 1 , 2022 .

[22]  Ciprian Catana,et al.  Toward Implementing an MRI-Based PET Attenuation-Correction Method for Neurologic Studies on the MR-PET Brain Prototype , 2010, The Journal of Nuclear Medicine.

[23]  John W. Clark,et al.  A motion-incorporated reconstruction method for gated PET studies , 2006, Physics in medicine and biology.

[24]  Doumit Daou,et al.  Respiratory motion handling is mandatory to accomplish the high-resolution PET destiny , 2008, European Journal of Nuclear Medicine and Molecular Imaging.

[25]  Xiaoyi Jiang,et al.  Respiratory Motion Correction in 3-D PET Data With Advanced Optical Flow Algorithms , 2008, IEEE Transactions on Medical Imaging.

[26]  Osama Mawlawi,et al.  Multimodality imaging: an update on PET/CT technology , 2009, European Journal of Nuclear Medicine and Molecular Imaging.

[27]  Lei Xing,et al.  Model-based image reconstruction for four-dimensional PET. , 2006, Medical physics.

[28]  Stephan G. Nekolla,et al.  Local motion correction for lung tumours in PET/CT—first results , 2008, European Journal of Nuclear Medicine and Molecular Imaging.

[29]  Andrés Santos,et al.  Unsupervised estimation of myocardial displacement from tagged MR sequences using nonrigid registration , 2008, Magnetic resonance in medicine.

[30]  Michael Unser,et al.  Optimization of mutual information for multiresolution image registration , 2000, IEEE Trans. Image Process..

[31]  P.M. Bloomfield,et al.  Rigid-body transformation of list-mode projection data for respiratory motion correction in cardiac PET , 2005, 2003 IEEE Nuclear Science Symposium. Conference Record (IEEE Cat. No.03CH37515).

[32]  Lars Stegger,et al.  Rigid-body transformation of list-mode projection data for respiratory motion correction in cardiac PET , 2003 .

[33]  Ciprian Catana,et al.  MRI-Assisted PET Motion Correction for Neurologic Studies in an Integrated MR-PET Scanner , 2011, The Journal of Nuclear Medicine.

[34]  Paul Kinahan,et al.  Cine CT for Attenuation Correction in Cardiac PET/CT , 2007, Journal of Nuclear Medicine.

[35]  G Malandain,et al.  Model-based respiratory motion compensation for emission tomography image reconstruction , 2007, Physics in medicine and biology.