Neural probe combining microelectrodes and a droplet-based microdialysis collection system for high temporal resolution sampling.

We propose a novel neural probe which combines microfluidic channels with recording and stimulation electrodes. The developed microfabrication approach enables the concentration of every active element such as electrodes and the sampling inlet in close proximity on the same surface. As a first approach, full functional validation is presented in this work (in vivo testing will be presented in the next study). Electrical characterization by impedance spectroscopy is performed in order to assess the electrode properties. An advanced experimental setup enabling the validation of the fluidic functions of the neural probe is also presented. It allowed the achievement of a high temporal resolution (170 ms) during sampling as a result of the integration of a T-junction droplet generator inside the probe. The droplets reached a volume of 0.84 nL and are separated by a non-aqueous phase (perfluoromethyldecalin, PFD). This probe represents an innovative tool for neuroscientists as it can be implanted in precise brain structures while combining electrical stimulation with sampling at a high temporal resolution.

[1]  Patrick A. Tresco,et al.  Impedance characterization of microarray recording electrodes in vitro , 2005, IEEE Transactions on Biomedical Engineering.

[2]  T. Stieglitz,et al.  Micromachined, Polyimide-Based Devices for Flexible Neural Interfaces , 2000 .

[3]  Silvestro Micera,et al.  Electronic dura mater for long-term multimodal neural interfaces , 2015, Science.

[4]  Scott T. Retterer,et al.  Model neural prostheses with integrated microfluidics: a potential intervention strategy for controlling reactive cell and tissue responses , 2004, IEEE Transactions on Biomedical Engineering.

[5]  Philippe Renaud,et al.  In Vivo Electrical Impedance Spectroscopy of Tissue Reaction to Microelectrode Arrays , 2009, IEEE Transactions on Biomedical Engineering.

[6]  T. Robinson,et al.  Transient changes in nucleus accumbens amino acid concentrations correlate with individual responsivity to the predator fox odor 2,5‐dihydro‐2,4,5‐trimethylthiazoline , 2006, Journal of neurochemistry.

[7]  F. Tortella,et al.  Intracranial pressure following penetrating ballistic-like brain injury in rats. , 2010, Journal of neurotrauma.

[8]  J. Y. Lettvin,et al.  Comments on Microelectrodes , 1959, Proceedings of the IRE.

[9]  G. Gabriel,et al.  SU-8 based microprobes with integrated planar electrodes for enhanced neural depth recording. , 2012, Biosensors & bioelectronics.

[10]  K. Wise,et al.  Performance of planar multisite microprobes in recording extracellular single-unit intracortical activity , 1988, IEEE Transactions on Biomedical Engineering.

[11]  S. Rossell,et al.  One-second time resolution brain microdialysis in fully awake rats. Protocol for the collection, separation and sorting of nanoliter dialysate volumes. , 2003, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[12]  David Beebe,et al.  1st Annual International IEEE-EMBS Special Topic Conference on Microtechnologies in Medicine & Biology, October 12-14, 2000, Palais des Congrès, Lyon, France : proceedings , 2000 .

[13]  R A Normann,et al.  The Utah intracortical Electrode Array: a recording structure for potential brain-computer interfaces. , 1997, Electroencephalography and clinical neurophysiology.

[14]  Helen Song,et al.  A microfluidic system for controlling reaction networks in time. , 2003, Angewandte Chemie.

[15]  Thomas W Vickroy,et al.  In vivo monitoring of amino acids by direct sampling of brain extracellular fluid at ultralow flow rates and capillary electrophoresis , 2002, Journal of Neuroscience Methods.

[16]  Amit Gupta,et al.  Effect of geometry on droplet formation in the squeezing regime in a microfluidic T-junction , 2010 .

[17]  Rustem F Ismagilov,et al.  The chemistrode: A droplet-based microfluidic device for stimulation and recording with high temporal, spatial, and chemical resolution , 2008, Proceedings of the National Academy of Sciences.

[18]  Rosa Villa,et al.  SU-8 based microprobes for simultaneous neural depth recording and drug delivery in the brain. , 2013, Lab on a chip.

[19]  P. Renaud,et al.  Flexible polyimide probes with microelectrodes and embedded microfluidic channels for simultaneous drug delivery and multi-channel monitoring of bioelectric activity. , 2004, Biosensors & bioelectronics.

[20]  V. Chefer,et al.  Detection and Quantification of Neurotransmitters in Dialysates , 2009, Current protocols in neuroscience.

[21]  T. Ljungberg,et al.  Classification of neuroleptic drugs according to their ability to inhibit apomorphine-induced locomotion and gnawing: Evidence for two different mechanisms of action , 1978, Psychopharmacology.

[22]  Justin C. Williams,et al.  Flexible polyimide-based intracortical electrode arrays with bioactive capability , 2001, IEEE Transactions on Biomedical Engineering.

[23]  G. Taylor Dispersion of soluble matter in solvent flowing slowly through a tube , 1953, Proceedings of the Royal Society of London. Series A. Mathematical and Physical Sciences.

[24]  F. Colbourne,et al.  Intracranial pressure measured in freely moving rats for days after intracerebral hemorrhage , 2014, Experimental Neurology.

[25]  J. Newman Resistance for Flow of Current to a Disk , 1966 .

[26]  K. Horch,et al.  A silicon-based, three-dimensional neural interface: manufacturing processes for an intracortical electrode array , 1991, IEEE Transactions on Biomedical Engineering.

[27]  J. Linderman,et al.  Push-pull perfusion sampling with segmented flow for high temporal and spatial resolution in vivo chemical monitoring. , 2011, Analytical chemistry.

[28]  A. Bertsch,et al.  Demonstration of cortical recording and reduced inflammatory response using flexible polymer neural probes , 2007, 2007 IEEE 20th International Conference on Micro Electro Mechanical Systems (MEMS).

[29]  H. Stone,et al.  Formation of dispersions using “flow focusing” in microchannels , 2003 .

[30]  U. Ungerstedt,et al.  Effects of apomorphine on the in vivo release of dopamine and its metabolites, studied by brain dialysis. , 1984, European journal of pharmacology.

[31]  P. Renaud,et al.  Polyimide and SU-8 microfluidic devices manufactured by heat-depolymerizable sacrificial material technique. , 2004, Lab on a chip.

[32]  R. Aris On the dispersion of a solute in a fluid flowing through a tube , 1956, Proceedings of the Royal Society of London. Series A. Mathematical and Physical Sciences.

[33]  R. Kennedy Emerging trends in in vivo neurochemical monitoring by microdialysis. , 2013, Current opinion in chemical biology.

[34]  K. Wise,et al.  A multichannel neural probe for selective chemical delivery at the cellular level , 1997, IEEE Transactions on Biomedical Engineering.

[35]  S. Kottegoda,et al.  Demonstration of low flow push–pull perfusion , 2002, Journal of Neuroscience Methods.

[36]  S. Herminghaus,et al.  Droplet based microfluidics , 2012, Reports on progress in physics. Physical Society.

[37]  Roland Zengerle,et al.  A versatile and flexible low-temperature full-wafer bonding process of monolithic 3D microfluidic structures in SU-8 , 2008 .