A general review of the Wilson plot method and its modifications to determine convection coefficients in heat exchange devices

Heat exchange devices are essential components in complex engineering systems related to energy generation and energy transformation in industrial scenarios. The calculation of convection coefficients constitutes a crucial issue in designing and sizing any type of heat exchange device. The Wilson plot method and its different modifications provide an outstanding tool for the analysis and design of convection heat transfer processes in research laboratories. The Wilson plot method deals with the determination of convection coefficients based on measured experimental data and the subsequent construction of appropriate correlation equations. This paper is to present an overview of the Wilson plot method along with numerous modifications introduced by researches throughout the years to improve its accuracy and to extend its use to a multitude of convective heat transfer problems. Undoubtedly, this information will be useful to thermal design engineers.

[1]  Samuel M. Sami,et al.  Boiling characteristics of alternatives to R-502 inside air/refrigerant enhanced surface tubing , 2000 .

[2]  Samuel M. Sami,et al.  Boiling characteristics of ternary mixtures inside enhanced surface tubing , 2000 .

[3]  Da Veiga,et al.  Characteristics of a semicircular heat exchanger used in a water heated condenser pump , 2009 .

[4]  André Bontemps,et al.  Filmwise condensation of a pure fluid and a binary mixture in a bundle of enhanced surface tubes , 2002 .

[5]  Jonathan Rose,et al.  Heat-transfer coefficients, Wilson plots and accuracy of thermal measurements , 2004 .

[6]  Allan P. Colburn,et al.  A method of correlating forced convection heat-transfer data and a comparison with fluid friction☆☆☆ , 1964 .

[7]  André Bontemps,et al.  Condensation Heat Transfer on Enhanced Surface Tubes: Experimental Results and Predictive Theory , 2002 .

[8]  C. C. Wang,et al.  Single-phase heat transfer and flow friction correlations for microfin tubes , 1996 .

[9]  Riad Benelmir,et al.  Identification du coefficient de transfert thermique sur la surface externe d'un échangeur de chaleur à tubes et ailettes planes en fonction de l'humidité de l'air, en l'absence de condensation , 1997 .

[10]  Ciro Aprea,et al.  Experimental evaluation of R22 and R407C evaporative heat transfer coefficients in a vapour compression plant , 2000 .

[11]  Josua P. Meyer,et al.  CONVECTION HEAT TRANSFER IN CONCENTRIC ANNULI , 2004 .

[12]  Ramesh K. Shah ASSESSMENT OF MODIFIED WILSON PLOT TECHNIQUES FOR OBTAINING HEAT EXCHANGER DESIGN DATA , 1990 .

[13]  Jostein Pettersen,et al.  Flow vaporization of CO2 in microchannel tubes , 2004 .

[14]  Timothy J. Rennie,et al.  NUMERICAL AND EXPERIMENTAL STUDIES OF A DOUBLE- PIPE HELICAL HEAT EXCHANGER , 2005 .

[15]  Agnieszka A. Lechowska,et al.  Unified Wilson Plot Method for Determining Heat Transfer Correlations for Heat Exchangers , 2003 .

[16]  Samuel M. Sami,et al.  Heat transfer of ternary mixtures inside enhanced surface tubing , 2000 .

[17]  S.-J. Yoo Post-CHF heat transfer with water and refrigerants , 1996 .

[18]  Ralph L. Webb,et al.  Prediction of two-phase heat transfer in a 4-pass evaporator bundle using single tube experimental data , 2004 .

[19]  Edwin Harold Young,et al.  Fouling of an 11-fins-per-inch coil in an internal tankless water heater , 1956 .

[20]  Cheng-Xian Lin,et al.  Condensation heat transfer and pressure drop characteristics of R-134a in an annular helical pipe , 2005 .

[21]  Edwin Harold Young,et al.  Effect of root wall thickness on bond resistance to heat transfer of bimetal tubes , 1954 .

[22]  Kiyoshi Saito,et al.  Heat transfer and pressure drop characteristics of enhanced titanium tubes , 2003 .

[23]  Adrian Briggs,et al.  Condensation of steam and R113 on a bank of horizontal tubes in the presence of a noncondensing gas , 1995 .

[24]  André Bontemps,et al.  Condensation heat transfer of a pure fluid and binary mixture outside a bundle of smooth horizontal tubes. Comparison of experimental results and a classical model , 2001 .

[25]  Jaco Dirker,et al.  Heat Transfer Coefficients in Concentric Annuli , 2002 .

[26]  Fang Xiaoming,et al.  Experimental study on heat transfer enhancement of a helically baffled heat exchanger combined with three-dimensional finned tubes , 2004 .

[27]  Tsing-Fa Lin,et al.  Saturated flow boiling heat transfer and pressure drop of refrigerant R-410A in a vertical plate heat exchanger , 2002 .

[28]  E. N. Sieder,et al.  Heat Transfer and Pressure Drop of Liquids in Tubes , 1936 .

[29]  J. Meyer,et al.  VALIDATION OF A CFD MODEL OF A THREE-DIMENSIONAL TUBE-IN-TUBE HEAT EXCHANGER , 2003 .

[30]  V. I. Gomelauri,et al.  Theoretical study of laminar film condensation of flowing vapour , 1966 .

[31]  D. D. Col,et al.  Heat Transfer Mechanisms for Condensation and Vaporization Inside a Microfin Tube , 2002 .

[32]  Andrea Gasparella,et al.  Experimental heat transfer coefficients during refrigerant vaporisation and condensation inside herringbone-type plate heat exchangers with enhanced surfaces , 2004 .

[33]  Chi-Chuan Wang,et al.  An experimental study of in-tube evaporation of R-22 inside a 6.5-mm smooth tube , 1998 .

[34]  Man-Hoe Kim,et al.  Evaporating heat transfer of R22 and R410A in horizontal smooth and microfin tubes , 2005 .

[35]  Josua P. Meyer,et al.  Influence of Spiral Angle on Heat Transfer during Condensation inside Spiralled Micro-Fin Tubes , 2005 .

[36]  Lixin Cheng,et al.  Experimental Study of Heat Transfer and Pressure Drop Characteristics of Air/Water and Air-Steam/Water Heat Exchange in a Polymer Compact Heat Exchanger , 2005 .

[37]  Samuel M. Sami,et al.  Prediction of condensation characteristics of alternatives to R-502 inside air–refrigerant enhanced surface tubing , 2000 .

[38]  Mo Se Kim,et al.  Performance and heat transfer characteristics of hydrocarbon refrigerants in a heat pump system , 2000 .

[39]  Edwin Harold Young,et al.  An investigation of the fouling of 19-fin-per-inch admiralty tubes in three heat transfer units located at the Aurora Gasoline Company refinery , 1956 .

[40]  Predrag Stojan Hrnjak,et al.  Experimental investigation of thermal contact resistance in plain-fin-and-tube evaporators with collarless fins , 2003 .

[41]  Nae-Hyun Kim,et al.  Condensation heat transfer of R-22 and R-410A in flat aluminum multi-channel tubes with or without micro-fins , 2003 .

[42]  Tsing-Fa Lin,et al.  Condensation heat transfer and pressure drop of refrigerant R-410A flow in a vertical plate heat exchanger , 2005 .

[43]  Dale E. Briggs,et al.  The condensing of low pressure steam on horizontal titanium tubes , 1963 .

[44]  Richard N. Christensen,et al.  An improved scheme for determining heat transfer correlations from heat exchanger regression models with three unknowns , 1992 .

[45]  R. L. Zhang,et al.  HEAT TRANSFER AND FRICTION IN SMALL DIAMETER CHANNELS , 1998 .

[46]  V. Gnielinski New equations for heat and mass transfer in turbulent pipe and channel flow , 1976 .

[47]  Ralph L. Webb,et al.  Heat transfer and friction characteristics of internal helical-rib roughness , 2000 .

[48]  Y. Y. Hsieh,et al.  Subcooled flow boiling heat transfer of R-134a and the associated bubble characteristics in a vertical plate heat exchanger , 2002 .

[49]  Sayeed Nusrulla Sami Flow boiling and condensation of tetrary refrigerant mixtures inside water/refrigerant enhanced surface tubing , 1997 .

[50]  S. Sami,et al.  Prediction of convective boiling characteristics of alternatives to R-502 inside air/refrigerant enhanced surface tubing , 2000 .

[51]  J. Thome,et al.  Heat Transfer Coefficients During Condensation of the Zeotropic Refrigerant Mixture HCFC-22/HCFC-142b , 2002 .

[52]  Robert E. Critoph,et al.  Contact resistance in air-cooled plate fin-tube air-conditioning condensers , 1996 .

[53]  Gerry B. Andeen,et al.  The Use of an Organic Self-Assembled Monolayer Coating to Promote Dropwise Condensation of Steam on Horizontal Tubes , 2000 .

[54]  Donald L. Katz,et al.  Performance of Finned Tubes in Shell-and-Tube Heat Exchangers , 1952, Journal of Fluids Engineering.

[55]  Samuel M. Sami,et al.  Two phase flow heat transfer of binary mixtures inside enhanced surface tubing , 1998 .

[56]  Samuel M. Sami,et al.  Two‐phase flow boiling characteristics of alternatives to R‐22 inside air/refrigerant enhanced surface tubing , 2000 .

[57]  Samuel M. Sami,et al.  Influence of magnetic field on two-phase flow convective boiling of some refrigerant mixtures , 2005 .

[58]  Samuel M. Sami,et al.  Experimental investigation of two phase flow condensation of alternatives to HCFC-22 inside enhanced surface tubing , 2000 .

[59]  Dale E. Briggs,et al.  The condensing of low pressure steam on vertical rows of horizontal copper and titanium tubes , 1966 .

[60]  B. M. Burnside,et al.  Dropwise Condensation of Steam on a Small Tube Bundle at Turbine Condenser Conditions , 2000 .

[61]  Hussam F. Khartabil A Modified Wilson Plot Technique for Determining Heat Transfer Correlations , 1987 .

[62]  J. Meyer,et al.  Condensation heat transfer coefficients of the zeotropic refrigerant mixture R-22/R-142b in smooth horizonal tubes , 2002 .

[63]  Satesh Narayana Namasivayam,et al.  Condensation of Ethylene Glycol on Integral-Fin Tubes: Effect of Fin Geometry and Vapor Velocity , 2005 .

[64]  G. P. Jin,et al.  Boiling of ammonia/lubricant mixture on a horizontal tube in a flooded evaporator with inlet vapor quality , 2006 .

[65]  Ru Yang,et al.  An experimental study of heat transfer in curved pipe with periodically varying curvature for application in solar collectors and heat exchangers , 2000, Collection of Technical Papers. 35th Intersociety Energy Conversion Engineering Conference and Exhibit (IECEC) (Cat. No.00CH37022).

[66]  Thierry Meyer,et al.  Reaction Calorimetry in Supercritical Carbon Dioxide , 2004 .

[67]  Kwan-Soo Lee,et al.  Investigation of heat transfer characteristics on various kinds of fin-and-tube heat exchangers with interrupted surfaces , 1999 .

[68]  Bikash Mohanty,et al.  Augmentation of outside tube heat transfer coefficient during condensation of steam over horizontal copper tubes , 1998 .

[69]  R. Y. Browne,et al.  Heat transfer coefficients. , 1936 .

[70]  Samuel M. Sami,et al.  Two‐phase flow convective condensation of refrigerant mixtures under gas/liquid injection , 2005 .

[71]  C. Kuo,et al.  In-tube evaporation of HCFC-22 in a 9 . 52 mm micro-fin / smooth tube , 2002 .

[72]  Josua P. Meyer,et al.  Convective Heat Transfer Coefficients in Concentric Annuli , 2005 .

[73]  L. Chamra,et al.  Single-phase heat transfer in micro-fin tubes , 1997 .

[74]  Josua P. Meyer,et al.  Heat Transfer Performance During Condensation Inside Spiralled Micro-Fin Tubes , 2004 .

[75]  Josua P. Meyer,et al.  Heat Transfer during Annular Tube Contact in a Helically Coiled Tube-in-Tube Heat Exchanger , 2005 .

[76]  Samuel M. Sami,et al.  Influence of gas/liquid injection on two‐phase flow convective boiling of refrigerant mixtures , 2004 .

[77]  Edwin Harold Young,et al.  The investigation of heat transfer and pressure drop of 11 fins per inch tubes and coils , 1955 .

[78]  Samuel M. Sami,et al.  Heat transfer and pressure drop characteristics of HFC quaternary refrigerant mixtures inside horizontal enhanced surface tubing , 1996 .

[79]  Bidyut Baran Saha,et al.  Development of a slug flow absorber working with ammonia-water mixture: part I—flow characterization and experimental investigation , 2003 .

[80]  Tsing-Fa Lin,et al.  Condensation heat transfer and pressure drop of refrigerant R-134a in a plate heat exchanger , 1999 .

[81]  Samuel M. Sami,et al.  Prediction of two-phase condensation characteristics of some alternatives to R-22 inside air/refrigerant enhanced surface tubing , 2000 .

[82]  José Fernández-Seara,et al.  Experimental apparatus for measuring heat transfer coefficients by the Wilson plot method , 2005 .

[83]  K. Wójs,et al.  Effects of the temperature interference on the results obtained using the Wilson plot technique , 1997 .

[84]  H. Gurney Heat Transmission , 1909, Nature.

[85]  MEASUREMENT OF FINNED-TUBE HEAT EXCHANGER PERFORMANCE , 2004 .

[86]  J. Fernández-Seara,et al.  Laboratory Practices with the Wilson Plot Method , 2007 .

[87]  André Bontemps,et al.  Experimental study and modelling of heat transfer during condensation of pure fluid and binary mixture on a bundle of horizontal finned tubes , 2003 .

[88]  F. Dittus,et al.  Heat transfer in automobile radiators of the tubular type , 1930 .

[89]  M. Molki,et al.  Electrohydrodynamic enhancement of R-134a condensation on enhanced tubes , 2000, Conference Record of the 2000 IEEE Industry Applications Conference. Thirty-Fifth IAS Annual Meeting and World Conference on Industrial Applications of Electrical Energy (Cat. No.00CH37129).

[90]  Samuel M. Sami,et al.  Influence of thermophysical properties on two-phase flow convective boiling of refrigerant mixtures , 2002 .

[91]  Josua P. Meyer,et al.  Heat Transfer and Pressure Drop Characteristics of Angled Spiraling Tape Inserts in a Heat Exchanger Annulus , 2001 .

[92]  Timothy R. Lonis,et al.  The effect of operating conditions on a reaction calorimeter , 1996 .

[93]  Floris Jakobus Smit Condensing coefficients of the refrigerant mixture R-22/R-142b in smooth tubes and during enhanced heat transfer configurations , 2009 .

[94]  Fadilah Hasim,et al.  Compound heat transfer enhancement by a combination of a helically ribbed tube with twisted tape inserts , 2003 .

[95]  P. Argyropoulos,et al.  Air–water two-phase flow and heat transfer in a plate heat exchanger , 2002 .

[96]  R. Webb,et al.  Condensation of R-12 in small hydraulic diameter extruded aluminum tubes with and without micro-fins , 1996 .

[97]  Satesh Narayana Namasivayam,et al.  Effect of vapour velocity on condensation of atmospheric pressure steam on integral-fin tubes , 2004 .

[98]  Ru Yang,et al.  An experimental heat transfer study for periodically varying-curvature curved-pipe , 2002 .

[99]  Thierry Meyer,et al.  Reaction Calorimetry as a New Tool for Supercritical Fluids , 2004 .

[100]  Josua P. Meyer,et al.  R-22 and Zeotropic R-22/R-142b Mixture Condensation in Microfin, High-Fin, and Twisted Tape Insert Tubes , 2002 .

[101]  Chi-Chuan Wang,et al.  Film condensation of HCFC-22 on horizontal enhanced tubes , 1996 .

[102]  Yeon-Pun Chang,et al.  Condensing heat transfer characteristics of aluminum flat tube , 1997 .

[103]  Samuel M. Sami,et al.  Heat transfer prediction of air‐to‐refrigerant two‐phase flow boiling of alternatives to HCFC‐22 inside air/refrigerant enhanced surface tubing , 2000 .

[104]  Ravi Kumar,et al.  Heat transfer during condensation of steam over a vertical grid of horizontal integral-fin copper tubes , 2001 .

[105]  Min Soo Kim,et al.  Single-phase heat transfer and pressure drop characteristics of an integral-spine-fin within an annulus , 1996 .

[106]  Fadilah Hasim,et al.  Compound Heat Transfer Enhancement by a Combination of Ribbed Tubes with Wire Coil Inserts , 2003 .

[107]  Jarosław Karwacki,et al.  Enhancement of condensation heat transfer by means of passive and active condensate drainage techniques , 2003 .

[108]  John R. Thome,et al.  Film Condensation of R-134a on Tube Arrays With Plain and Enhanced Surfaces: Part I—Experimental Heat Transfer Coefficients , 2006 .

[109]  Bengt Sundén,et al.  An experimental and theoretical investigation of the effect of flow maldistribution on the thermal performance of plate heat exchangers , 2005 .

[110]  Jarosław Karwacki,et al.  Enhancement of condensation heat transfer by means of EHD condensate drainage , 2002 .

[111]  Bikash Mohanty,et al.  A Comprehensive Study of Modified Wilson Plot Technique to Determine the Heat Transfer Coefficient during Condensation of Steam and R-134a over Single Horizontal Plain and Finned Tubes , 2001 .

[112]  P Alexander,et al.  A semiempirical approach to a viscously damped oscillating sphere , 2005 .

[113]  John R. Thome,et al.  Nucleate boiling heat transfer of R134a on enhanced tubes , 2006 .