Stable Calibrations of Six-DOF Serial Robots by Using Identification Models with Equalized Singular Values

SUMMARY In typical calibration methods (kinematic or non-kinematic) for serial industrial robot, though measurement instruments with high resolutions are adopted, measurement configurations are optimized, and redundant parameters are eliminated from identification model, calibration accuracy is still limited under measurement noise. This might be because huge gaps still exist among the singular values of typical identification Jacobians, thereby causing the identification models ill conditioned. This paper addresses such problem by using new identification models established in two steps. First, the typical models are divided into the submodels with truncated singular values. In this way, the unknown parameters corresponding to the abnormal singular values are removed, thereby reducing the condition numbers of the new submodels. However, these models might still be ill conditioned. Therefore, the second step is to further centralize the singular values of each submodel by using a matrix balance method. Afterward, all submodels are well conditioned and obtain much higher observability indices compared with those of typical models. Simulation results indicate that significant improvements in the stability of identification results and the identifiability of unknown parameters are acquired by using the new identification submodels. Experimental results indicate that the proposed calibration method increases the identification accuracy without incurring additional hardware setup costs to the typical calibration method.

[1]  Stéphane Caro,et al.  Identification of the manipulator stiffness model parameters in industrial environment , 2015 .

[2]  Cheng Li,et al.  POE-Based Robot Kinematic Calibration Using Axis Configuration Space and the Adjoint Error Model , 2016, IEEE Transactions on Robotics.

[3]  Chia-Hsiang Menq,et al.  Determination of Optimal Measurement Configurations for Robot Calibration Based on Observability Measure , 1991, Int. J. Robotics Res..

[4]  John M. Hollerbach,et al.  The noise amplification index for optimal pose selection in robot calibration , 1996, Proceedings of IEEE International Conference on Robotics and Automation.

[5]  Carlos Javierre,et al.  ROTATION ERROR MODELING AND IDENTIFICATION FOR ROBOT KINEMATIC CALIBRATION BY CIRCLE POINT METHOD , 2014 .

[6]  Youping Chen,et al.  A novel calibration method for multi-robots system utilizing calibration model without nominal kinematic parameters , 2017 .

[7]  Robert G. Landers,et al.  Modeling and calibration of high-order joint-dependent kinematic errors for industrial robots , 2018 .

[8]  Ilian A. Bonev,et al.  Optimal Experiment Design for Elasto-Geometrical Calibration of Industrial Robots , 2019, IEEE/ASME Transactions on Mechatronics.

[9]  Qiuju Zhang,et al.  Non-kinematic calibration of industrial robots using a rigid–flexible coupling error model and a full pose measurement method , 2019, Robotics and Computer-Integrated Manufacturing.

[10]  Elie A. Shammas,et al.  Kinematic calibration of serial manipulators using Bayesian inference , 2018, Robotica.

[11]  Ilian A. Bonev,et al.  Non-kinematic calibration of a six-axis serial robot using planar constraints , 2015 .

[12]  Dong Zhao,et al.  Kinematic calibration of a 6-DOF hybrid robot by considering multicollinearity in the identification Jacobian , 2019, Mechanism and Machine Theory.

[13]  Ilian A. Bonev,et al.  Performances of observability indices for industrial robot calibration , 2016, 2016 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS).

[14]  Luo Fei,et al.  An Overview of Robot Calibration , 2004 .

[15]  Yu Guo,et al.  Structural parameter identification for 6 DOF industrial robots , 2017 .

[16]  Toby J. Mitchell,et al.  An Algorithm for the Construction of “D-Optimal” Experimental Designs , 2000, Technometrics.

[17]  Ilian A. Bonev,et al.  Absolute calibration of an ABB IRB 1600 robot using a laser tracker , 2013 .

[18]  Hao Wang,et al.  A Simple Two-step Geometric Approach for the Kinematic Calibration of the 3-PRS Parallel Manipulator , 2019, Robotica.

[19]  Chen-Gang,et al.  Review on kinematics calibration technology of serial robots , 2014 .

[20]  Bahram Ravani,et al.  An overview of robot calibration , 1987, IEEE Journal on Robotics and Automation.

[21]  Jinguo Liu,et al.  An improved kinematic calibration method for serial manipulators based on POE formula , 2018, Robotica.

[22]  Stéphane Caro,et al.  Geometric calibration of industrial robots using enhanced partial pose measurements and design of experiments , 2015 .

[23]  Cheng Li,et al.  Easy industrial robot cell coordinates calibration with touch panel , 2018 .

[24]  Andreas Archenti,et al.  Closed-force-loop elastostatic calibration of serial articulated robots , 2019, Robotics and Computer-Integrated Manufacturing.

[25]  Fei Liu,et al.  Calibration method of robot base frame using unit quaternion form , 2015 .

[26]  Hyun Min Do,et al.  Screw based kinematic calibration method for robot manipulators with joint compliance using circular point analysis , 2019, Robotics Comput. Integr. Manuf..

[27]  Jun Ni,et al.  Nongeometric error identification and compensation for robotic system by inverse calibration , 2000 .

[28]  Jian S. Dai,et al.  Analysis of unified error model and simulated parameters calibration for robotic machining based on Lie theory , 2020, Robotics Comput. Integr. Manuf..

[29]  K. S. Venkatesh,et al.  Position-Based Visual Servoing of a Mobile Robot with an Automatic Extrinsic Calibration Scheme , 2019, Robotica.

[30]  Ilian A. Bonev,et al.  Absolute robot calibration with a single telescoping ballbar , 2014 .